Parameter determination of 0.5 hp induction motor based on load factor test - A case study

Link to publisher's homepage at http://ieeexplore.ieee.org/

Saved in:
Bibliographic Details
Main Authors: Ismail, Daut, Prof. Dr., Gomesh Nair, Shasidharan, Muhammad Irwanto, Yanawati, Y., Nor Shafiqin, S., Mohd Irwan, Yusoff
Format: Working Paper
Language:English
Published: Institute of Electrical and Electronics Engineers (IEEE) 2011
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/15086
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-15086
record_format dspace
spelling my.unimap-150862011-10-27T06:26:41Z Parameter determination of 0.5 hp induction motor based on load factor test - A case study Ismail, Daut, Prof. Dr. Gomesh Nair, Shasidharan Muhammad Irwanto Yanawati, Y. Nor Shafiqin, S. Mohd Irwan, Yusoff Efficiency Energy consumption Load factor Mechanical output power Motor losses Link to publisher's homepage at http://ieeexplore.ieee.org/ The load can influence the efficiency of the induction motor. Even if the load has higher or less load factor, it can reduce the efficiency of an induction motor by several percentage. By knowing this, it is important that an induction motor be loaded with an appropriate or load factor of 100%. In this paper, the experiment is conducted to prove that efficiency decreases when the 0.5 hp induction motor's is interfaced under low load factor condition and in this case a 65% load factor. The induction motor is interfaced with a DC generator and a variable resistance as load. In order to determined the efficiency and the mechanical output power of the induction motor, the voltage of the induction motor is varied from 0-415 volt and the appropriate data is taken. This is then analysis and several calculation formulas are used to determine the motor's parameters. After that the losses are segregated and from this we can compare the efficiency values in which it shows low efficiency of 66.62% based on output/input method and 66.34% by using the losses formula. This proofs that at low load factor the efficiency of the induction motor reduces. 2011-10-27T06:26:41Z 2011-10-27T06:26:41Z 2011-06-21 Working Paper p. 477-480 978-1-6128-4228-8 http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5953929 http://hdl.handle.net/123456789/15086 en Proceedings of the 1st International Conference on Electrical, Control and Computer Engineering 2011 (InECCE 2011) Institute of Electrical and Electronics Engineers (IEEE)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Efficiency
Energy consumption
Load factor
Mechanical output power
Motor losses
spellingShingle Efficiency
Energy consumption
Load factor
Mechanical output power
Motor losses
Ismail, Daut, Prof. Dr.
Gomesh Nair, Shasidharan
Muhammad Irwanto
Yanawati, Y.
Nor Shafiqin, S.
Mohd Irwan, Yusoff
Parameter determination of 0.5 hp induction motor based on load factor test - A case study
description Link to publisher's homepage at http://ieeexplore.ieee.org/
format Working Paper
author Ismail, Daut, Prof. Dr.
Gomesh Nair, Shasidharan
Muhammad Irwanto
Yanawati, Y.
Nor Shafiqin, S.
Mohd Irwan, Yusoff
author_facet Ismail, Daut, Prof. Dr.
Gomesh Nair, Shasidharan
Muhammad Irwanto
Yanawati, Y.
Nor Shafiqin, S.
Mohd Irwan, Yusoff
author_sort Ismail, Daut, Prof. Dr.
title Parameter determination of 0.5 hp induction motor based on load factor test - A case study
title_short Parameter determination of 0.5 hp induction motor based on load factor test - A case study
title_full Parameter determination of 0.5 hp induction motor based on load factor test - A case study
title_fullStr Parameter determination of 0.5 hp induction motor based on load factor test - A case study
title_full_unstemmed Parameter determination of 0.5 hp induction motor based on load factor test - A case study
title_sort parameter determination of 0.5 hp induction motor based on load factor test - a case study
publisher Institute of Electrical and Electronics Engineers (IEEE)
publishDate 2011
url http://dspace.unimap.edu.my/xmlui/handle/123456789/15086
_version_ 1643791383565172736
score 13.222552