Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia
In the last decade, energy consumption for air conditioning applications has been dramatically rising because of the growing global population and increasing comfort demand. Consequently, direct evaporative cooling (DEC) technology is emerging as an alternative to vapour compression air conditioners...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Semarak Ilmu Publishing
2022
|
Subjects: | |
Online Access: | https://eprints.ums.edu.my/id/eprint/33657/1/Performance%20of%20the%20direct%20evaporative%20cooler%20%28DEC%29%20operating%20in%20a%20hot%20and%20humid%20region%20of%20Sabah%20Malaysia.ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/33657/2/Performance%20of%20The%20Direct%20Evaporative%20Cooler%20%28DEC%29%20Operating%20in%20A%20Hot%20and%20Humid%20Region%20of%20Sabah%20Malaysia.pdf https://eprints.ums.edu.my/id/eprint/33657/ https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/86/243 https://doi.org/10.37934/arfmts.93.2.1727 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ums.eprints.33657 |
---|---|
record_format |
eprints |
spelling |
my.ums.eprints.336572022-08-03T03:20:02Z https://eprints.ums.edu.my/id/eprint/33657/ Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia Zulkurnain Hassan Mohd Suffian Misaran@Misran Nancy Julius Siambun TH1-9745 Building construction TP480-498 Low temperature engineering. Cryogenic engineering. Refrigeration In the last decade, energy consumption for air conditioning applications has been dramatically rising because of the growing global population and increasing comfort demand. Consequently, direct evaporative cooling (DEC) technology is emerging as an alternative to vapour compression air conditioners due to its lower environmental impacts, less energy consumption, and lower operating costs. This paper aims to evaluate the efficiency of direct evaporators in hot, humid environments like Malaysia. Inlet and outlet temperatures, saturation efficiency, cooling capability, and feasibility index are all used to evaluate results. The cooling medium was a rectangular honeycomb cooling pad with a length of 34 cm, a width of 25 cm, and a thickness of 3.5 cm. The temperature and humidity during the analysis were between 31 and 35oC and 47.5 and 65.5%, respectively. The results showed that the air output temperature varied between 28.4°C and 31.7°C, while the cooling capacity between 0.29 kW and 0.64 kW as well as the saturation efficiency between 46% to 80% could be achieved. The result also showed a feasibility index between 19 to 24. Due to the high value of the feasibility index, this evaporative cooling does not work well in the territory of Malaysia. A direct evaporative cooler may be made to work in humid places like Malaysia by drying the air before the evaporative process using the desiccant dehumidification concept. Semarak Ilmu Publishing 2022-03-16 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/33657/1/Performance%20of%20the%20direct%20evaporative%20cooler%20%28DEC%29%20operating%20in%20a%20hot%20and%20humid%20region%20of%20Sabah%20Malaysia.ABSTRACT.pdf text en https://eprints.ums.edu.my/id/eprint/33657/2/Performance%20of%20The%20Direct%20Evaporative%20Cooler%20%28DEC%29%20Operating%20in%20A%20Hot%20and%20Humid%20Region%20of%20Sabah%20Malaysia.pdf Zulkurnain Hassan and Mohd Suffian Misaran@Misran and Nancy Julius Siambun (2022) Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 93. pp. 17-27. ISSN 2811-3950 https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/86/243 https://doi.org/10.37934/arfmts.93.2.1727 |
institution |
Universiti Malaysia Sabah |
building |
UMS Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sabah |
content_source |
UMS Institutional Repository |
url_provider |
http://eprints.ums.edu.my/ |
language |
English English |
topic |
TH1-9745 Building construction TP480-498 Low temperature engineering. Cryogenic engineering. Refrigeration |
spellingShingle |
TH1-9745 Building construction TP480-498 Low temperature engineering. Cryogenic engineering. Refrigeration Zulkurnain Hassan Mohd Suffian Misaran@Misran Nancy Julius Siambun Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
description |
In the last decade, energy consumption for air conditioning applications has been dramatically rising because of the growing global population and increasing comfort demand. Consequently, direct evaporative cooling (DEC) technology is emerging as an alternative to vapour compression air conditioners due to its lower environmental impacts, less energy consumption, and lower operating costs. This paper aims to evaluate the efficiency of direct evaporators in hot, humid environments like Malaysia. Inlet and outlet temperatures, saturation efficiency, cooling capability, and feasibility index are all used to evaluate results. The cooling medium was a rectangular honeycomb cooling pad with a length of 34 cm, a width of 25 cm, and a thickness of 3.5 cm. The temperature and humidity during the analysis were between 31 and 35oC and 47.5 and 65.5%, respectively. The results showed that the air output temperature varied between 28.4°C and 31.7°C, while the cooling capacity between 0.29 kW and 0.64 kW as well as the saturation efficiency between 46% to 80% could be achieved. The result also showed a feasibility index between 19 to 24. Due to the high value of the feasibility index, this evaporative cooling does not work well in the territory of Malaysia. A direct evaporative cooler may be made to work in humid places like Malaysia by drying the air before the evaporative process using the desiccant dehumidification concept. |
format |
Article |
author |
Zulkurnain Hassan Mohd Suffian Misaran@Misran Nancy Julius Siambun |
author_facet |
Zulkurnain Hassan Mohd Suffian Misaran@Misran Nancy Julius Siambun |
author_sort |
Zulkurnain Hassan |
title |
Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
title_short |
Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
title_full |
Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
title_fullStr |
Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
title_full_unstemmed |
Performance of the direct evaporative cooler (DEC) operating in a hot and humid region of Sabah Malaysia |
title_sort |
performance of the direct evaporative cooler (dec) operating in a hot and humid region of sabah malaysia |
publisher |
Semarak Ilmu Publishing |
publishDate |
2022 |
url |
https://eprints.ums.edu.my/id/eprint/33657/1/Performance%20of%20the%20direct%20evaporative%20cooler%20%28DEC%29%20operating%20in%20a%20hot%20and%20humid%20region%20of%20Sabah%20Malaysia.ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/33657/2/Performance%20of%20The%20Direct%20Evaporative%20Cooler%20%28DEC%29%20Operating%20in%20A%20Hot%20and%20Humid%20Region%20of%20Sabah%20Malaysia.pdf https://eprints.ums.edu.my/id/eprint/33657/ https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/86/243 https://doi.org/10.37934/arfmts.93.2.1727 |
_version_ |
1760231191836884992 |
score |
13.214268 |