Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation

This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, f...

Full description

Saved in:
Bibliographic Details
Main Authors: Rechard Lee, Abdullah Bade, Salina Sulaiman, Siti Hasnah Tanalol
Format: Article
Language:English
English
Published: 2013
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf
https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf
https://eprints.ums.edu.my/id/eprint/27490/
http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ums.eprints.27490
record_format eprints
spelling my.ums.eprints.274902021-06-29T00:49:58Z https://eprints.ums.edu.my/id/eprint/27490/ Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation Rechard Lee Abdullah Bade Salina Sulaiman Siti Hasnah Tanalol R Medicine (General) This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, first - detect and extract local features and second – visualization and rendering. Our focus is the first part of the whole operation – features. We proposed marker-less approach as to avoid the needs to prepare the target environment and to make our approach more flexible. The proposed method starts with first getting an input from the real environment through a camera as visual sensor. On receiving an input image, the proposed system will process the image, finds and detects strong interest point from the ROI by applying enhanced contour-corner detection. From the ROI, features such as number of corners and vertices can be extracted and later can be used to determine a marker. For testing purposes, a mannequin as an input is used. Based on the experiment, the proposed method manage to capture the environment, convert captured frame into grey-scale image, detect corners and contours and also able to identify and verify a marker. 2013 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf text en https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf Rechard Lee and Abdullah Bade and Salina Sulaiman and Siti Hasnah Tanalol (2013) Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation. Journal of Medical and Bioengineering, 2 (1). pp. 71-74. ISSN 2199-​4757 http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf
institution Universiti Malaysia Sabah
building UMS Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sabah
content_source UMS Institutional Repository
url_provider http://eprints.ums.edu.my/
language English
English
topic R Medicine (General)
spellingShingle R Medicine (General)
Rechard Lee
Abdullah Bade
Salina Sulaiman
Siti Hasnah Tanalol
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
description This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, first - detect and extract local features and second – visualization and rendering. Our focus is the first part of the whole operation – features. We proposed marker-less approach as to avoid the needs to prepare the target environment and to make our approach more flexible. The proposed method starts with first getting an input from the real environment through a camera as visual sensor. On receiving an input image, the proposed system will process the image, finds and detects strong interest point from the ROI by applying enhanced contour-corner detection. From the ROI, features such as number of corners and vertices can be extracted and later can be used to determine a marker. For testing purposes, a mannequin as an input is used. Based on the experiment, the proposed method manage to capture the environment, convert captured frame into grey-scale image, detect corners and contours and also able to identify and verify a marker.
format Article
author Rechard Lee
Abdullah Bade
Salina Sulaiman
Siti Hasnah Tanalol
author_facet Rechard Lee
Abdullah Bade
Salina Sulaiman
Siti Hasnah Tanalol
author_sort Rechard Lee
title Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
title_short Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
title_full Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
title_fullStr Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
title_full_unstemmed Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
title_sort real-time pre-placed marker-less square-roi verification system based on contour-corner approach for breast augmentation
publishDate 2013
url https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf
https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf
https://eprints.ums.edu.my/id/eprint/27490/
http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf
_version_ 1760230628374085632
score 13.214268