Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation
This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, f...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
2013
|
Subjects: | |
Online Access: | https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf https://eprints.ums.edu.my/id/eprint/27490/ http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ums.eprints.27490 |
---|---|
record_format |
eprints |
spelling |
my.ums.eprints.274902021-06-29T00:49:58Z https://eprints.ums.edu.my/id/eprint/27490/ Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation Rechard Lee Abdullah Bade Salina Sulaiman Siti Hasnah Tanalol R Medicine (General) This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, first - detect and extract local features and second – visualization and rendering. Our focus is the first part of the whole operation – features. We proposed marker-less approach as to avoid the needs to prepare the target environment and to make our approach more flexible. The proposed method starts with first getting an input from the real environment through a camera as visual sensor. On receiving an input image, the proposed system will process the image, finds and detects strong interest point from the ROI by applying enhanced contour-corner detection. From the ROI, features such as number of corners and vertices can be extracted and later can be used to determine a marker. For testing purposes, a mannequin as an input is used. Based on the experiment, the proposed method manage to capture the environment, convert captured frame into grey-scale image, detect corners and contours and also able to identify and verify a marker. 2013 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf text en https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf Rechard Lee and Abdullah Bade and Salina Sulaiman and Siti Hasnah Tanalol (2013) Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation. Journal of Medical and Bioengineering, 2 (1). pp. 71-74. ISSN 2199-4757 http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf |
institution |
Universiti Malaysia Sabah |
building |
UMS Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sabah |
content_source |
UMS Institutional Repository |
url_provider |
http://eprints.ums.edu.my/ |
language |
English English |
topic |
R Medicine (General) |
spellingShingle |
R Medicine (General) Rechard Lee Abdullah Bade Salina Sulaiman Siti Hasnah Tanalol Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
description |
This paper aims to enhance the current contour and corner detection approach by applying smoothing and adaptive thresholding techniques to the stream input and then use subpixel corner detection to obtain better and more accurate interest point. There are two main steps involved in AR application, first - detect and extract local features and second – visualization and rendering. Our focus is the first part of the whole operation – features. We proposed marker-less approach as to avoid the needs to prepare the target environment and to make our approach more flexible. The proposed method starts with first getting an input from the real environment through a camera as visual sensor. On receiving an input image, the proposed system will process the image, finds and detects strong interest point from the ROI by applying enhanced contour-corner detection. From the ROI, features such as number of corners and vertices can be extracted and later can be used to determine a marker. For testing purposes, a mannequin as an input is used. Based on the experiment, the proposed method manage to capture the environment, convert captured frame into grey-scale image, detect corners and contours and also able to identify and verify a marker. |
format |
Article |
author |
Rechard Lee Abdullah Bade Salina Sulaiman Siti Hasnah Tanalol |
author_facet |
Rechard Lee Abdullah Bade Salina Sulaiman Siti Hasnah Tanalol |
author_sort |
Rechard Lee |
title |
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
title_short |
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
title_full |
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
title_fullStr |
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
title_full_unstemmed |
Real-time pre-placed marker-less square-ROI verification system based on contour-corner approach for breast augmentation |
title_sort |
real-time pre-placed marker-less square-roi verification system based on contour-corner approach for breast augmentation |
publishDate |
2013 |
url |
https://eprints.ums.edu.my/id/eprint/27490/1/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20ABSTRACT.pdf https://eprints.ums.edu.my/id/eprint/27490/2/Real-time%20pre-placed%20marker-less%20square-ROI%20verification%20system%20based%20on%20contour-corner%20approach%20for%20breast%20augmentation%20FULL%20TEXT.pdf https://eprints.ums.edu.my/id/eprint/27490/ http://www.jomb.org/uploadfile/2013/0424/20130424041947850.pdf |
_version_ |
1760230628374085632 |
score |
13.214268 |