Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift

"The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Mizanur Rahman, Md. Assad-Uz-zaman, Mohammad Mashud
Format: Article
Language:English
Published: 2014
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf
https://eprints.ums.edu.my/id/eprint/19537/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ums.eprints.19537
record_format eprints
spelling my.ums.eprints.195372018-03-22T02:05:12Z https://eprints.ums.edu.my/id/eprint/19537/ Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift Md. Mizanur Rahman Md. Assad-Uz-zaman Mohammad Mashud TJ Mechanical engineering and machinery "The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given head loss through the pump, which implies, when the suction flow rate is maximum. However, suction lift is inversely proportional to flow rate. But in the field of application there are many cases (such as drainage, dredging, well-pumping and other systems) where suction lift is more important factor than any other for water jet pumps, which gives importance to the assessment of depending factor of suction lift of water jet pumps. Six different jet pumps of two different nominal diameter each of three different nozzle to throat area ratio were made to carry out this experiment. The results revealed that the nozzle-to-throat area ratio was an important parameter to characterize the suction lift of the jet pumps, but nominal diameter had a negligible play role. 2014 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf Md. Mizanur Rahman and Md. Assad-Uz-zaman and Mohammad Mashud (2014) Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift. International Journal of Mechanical & Mechatronics Engineering IJMME, 14 (3). pp. 45-47.
institution Universiti Malaysia Sabah
building UMS Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sabah
content_source UMS Institutional Repository
url_provider http://eprints.ums.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
description "The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given head loss through the pump, which implies, when the suction flow rate is maximum. However, suction lift is inversely proportional to flow rate. But in the field of application there are many cases (such as drainage, dredging, well-pumping and other systems) where suction lift is more important factor than any other for water jet pumps, which gives importance to the assessment of depending factor of suction lift of water jet pumps. Six different jet pumps of two different nominal diameter each of three different nozzle to throat area ratio were made to carry out this experiment. The results revealed that the nozzle-to-throat area ratio was an important parameter to characterize the suction lift of the jet pumps, but nominal diameter had a negligible play role.
format Article
author Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
author_facet Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
author_sort Md. Mizanur Rahman
title Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_short Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_full Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_fullStr Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_full_unstemmed Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_sort performance evaluation of water jet pump for nozzle to throat area ratios on suction lift
publishDate 2014
url https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf
https://eprints.ums.edu.my/id/eprint/19537/