Air heating unit is one of the most important parts in paddy drying to ensure the efficiency of a drying process. In addition, an optimized air heating unit does not only promise a good paddy quality, but also save more for the operating cost. This study determined the suitable and best specificatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Adrian Jidon Januan, Nor Hidayah Kamin, K. H. Wong, H. J. Tham, Valerian Victor Kong, Majid Farajpourlar
Format: Conference or Workshop Item
Language:English
Published: 2015
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/19196/1/Design%20and%20simulation%20of%20heat%20exchangers%20.pdf
https://eprints.ums.edu.my/id/eprint/19196/
http://doi.org/10.1088/1755-1315/36/1/012056
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ums.eprints.19196
record_format eprints
spelling my.ums.eprints.191962018-03-21T05:41:35Z https://eprints.ums.edu.my/id/eprint/19196/ Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application Adrian Jidon Januan Nor Hidayah Kamin K. H. Wong H. J. Tham Valerian Victor Kong Majid Farajpourlar TJ Mechanical engineering and machinery Air heating unit is one of the most important parts in paddy drying to ensure the efficiency of a drying process. In addition, an optimized air heating unit does not only promise a good paddy quality, but also save more for the operating cost. This study determined the suitable and best specifications heating unit to heat air for paddy drying in the LAMB dryer. In this study, Aspen HYSYS v7.3 was used to obtain the minimum flow rate of hot water needed. The resulting data obtained from Aspen HYSYS v7.3 were used in Aspen Exchanger Design and Rating (EDR) to generate heat exchanger design and costs. The designs include shell and tubes and plate heat exchanger. The heat exchanger was designed in order to produce various drying temperatures of 40, 50, 60 and 70°C of air with different flow rate, 300, 2500 and 5000 LPM. The optimum condition for the heat exchanger were found to be plate heat exchanger with 0.6 mm plate thickness, 198.75 mm plate width, 554.8 mm plate length and 11 numbers of plates operating at 5000 LPM air flow rate. 2015 Conference or Workshop Item PeerReviewed text en https://eprints.ums.edu.my/id/eprint/19196/1/Design%20and%20simulation%20of%20heat%20exchangers%20.pdf Adrian Jidon Januan and Nor Hidayah Kamin and K. H. Wong and H. J. Tham and Valerian Victor Kong and Majid Farajpourlar (2015) Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application. In: 5th International Conference on Chemical and Bioprocess Engineering, ICCBPE 2015, 9 - 12 December 2015, The Pacific Sutera Hotel Kota Kinabalu, Sabah. http://doi.org/10.1088/1755-1315/36/1/012056
institution Universiti Malaysia Sabah
building UMS Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sabah
content_source UMS Institutional Repository
url_provider http://eprints.ums.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Adrian Jidon Januan
Nor Hidayah Kamin
K. H. Wong
H. J. Tham
Valerian Victor Kong
Majid Farajpourlar
Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
description Air heating unit is one of the most important parts in paddy drying to ensure the efficiency of a drying process. In addition, an optimized air heating unit does not only promise a good paddy quality, but also save more for the operating cost. This study determined the suitable and best specifications heating unit to heat air for paddy drying in the LAMB dryer. In this study, Aspen HYSYS v7.3 was used to obtain the minimum flow rate of hot water needed. The resulting data obtained from Aspen HYSYS v7.3 were used in Aspen Exchanger Design and Rating (EDR) to generate heat exchanger design and costs. The designs include shell and tubes and plate heat exchanger. The heat exchanger was designed in order to produce various drying temperatures of 40, 50, 60 and 70°C of air with different flow rate, 300, 2500 and 5000 LPM. The optimum condition for the heat exchanger were found to be plate heat exchanger with 0.6 mm plate thickness, 198.75 mm plate width, 554.8 mm plate length and 11 numbers of plates operating at 5000 LPM air flow rate.
format Conference or Workshop Item
author Adrian Jidon Januan
Nor Hidayah Kamin
K. H. Wong
H. J. Tham
Valerian Victor Kong
Majid Farajpourlar
author_facet Adrian Jidon Januan
Nor Hidayah Kamin
K. H. Wong
H. J. Tham
Valerian Victor Kong
Majid Farajpourlar
author_sort Adrian Jidon Januan
title Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
title_short Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
title_full Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
title_fullStr Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
title_full_unstemmed Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application
title_sort design and simulation of heat exchangers using aspen hysys, and aspen exchanger design and rating for paddy drying application
publishDate 2015
url https://eprints.ums.edu.my/id/eprint/19196/1/Design%20and%20simulation%20of%20heat%20exchangers%20.pdf
https://eprints.ums.edu.my/id/eprint/19196/
http://doi.org/10.1088/1755-1315/36/1/012056
_version_ 1760229548542132224
score 13.18916