Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer.
Having a stable and steady calibration constants increases the likelihood of a spectrometer to perform as expected over a reasonable period of time. The purpose of this paper is to study the variation over time of the Du Mortier calibration algorithm used in a spectrometer for atmospheric condition...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
American-Eurasian Network for Scientific Information (AENSI)
2016
|
Subjects: | |
Online Access: | https://eprints.ums.edu.my/id/eprint/18493/1/Variation%20Over%20Time%20of%20the%20Du%20Mortier%20Calibration%20Algorithm%20for%20Ground.pdf https://eprints.ums.edu.my/id/eprint/18493/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ums.eprints.18493 |
---|---|
record_format |
eprints |
spelling |
my.ums.eprints.184932018-01-29T15:00:58Z https://eprints.ums.edu.my/id/eprint/18493/ Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. Awang Bono Duduku Krishnaiah Mariani Rajin Nancy J. Siambun QC Physics Having a stable and steady calibration constants increases the likelihood of a spectrometer to perform as expected over a reasonable period of time. The purpose of this paper is to study the variation over time of the Du Mortier calibration algorithm used in a spectrometer for atmospheric condition measurement. This is carried out over a course of six months and the measurements were taken for every minute intervals from 8.30am to 4.30pm in three locations in Kota Kinabalu. By using the improved Langley method, monthly calibration constants for eight wavelengths were determined for Du Mortier model. Results shows that there were statistically significant differences between mean calibration constants when comparing the selected months. However, if only wavelengths of 460nm, 500nm, 540nm, 580nm and 620nm are taken into account, the results say otherwise. American-Eurasian Network for Scientific Information (AENSI) 2016 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/18493/1/Variation%20Over%20Time%20of%20the%20Du%20Mortier%20Calibration%20Algorithm%20for%20Ground.pdf Awang Bono and Duduku Krishnaiah and Mariani Rajin and Nancy J. Siambun (2016) Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. Advances in Environmental Biology, 9 (10). pp. 713-716. ISSN 1995-0756 |
institution |
Universiti Malaysia Sabah |
building |
UMS Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sabah |
content_source |
UMS Institutional Repository |
url_provider |
http://eprints.ums.edu.my/ |
language |
English |
topic |
QC Physics |
spellingShingle |
QC Physics Awang Bono Duduku Krishnaiah Mariani Rajin Nancy J. Siambun Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
description |
Having a stable and steady calibration constants increases the likelihood of a spectrometer to perform as expected over a reasonable period of time. The purpose of this paper is to study the variation over time of the Du Mortier calibration algorithm used in a spectrometer for atmospheric condition measurement. This is carried out over a course of six months and the measurements were taken for every minute intervals from 8.30am to 4.30pm in three locations in Kota Kinabalu. By using the improved Langley method, monthly calibration constants for eight wavelengths were determined for Du Mortier model. Results shows that there were statistically significant differences between mean calibration constants when comparing the selected months. However, if only wavelengths of 460nm, 500nm, 540nm, 580nm and 620nm are taken into account, the results say otherwise. |
format |
Article |
author |
Awang Bono Duduku Krishnaiah Mariani Rajin Nancy J. Siambun |
author_facet |
Awang Bono Duduku Krishnaiah Mariani Rajin Nancy J. Siambun |
author_sort |
Awang Bono |
title |
Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
title_short |
Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
title_full |
Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
title_fullStr |
Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
title_full_unstemmed |
Variation over time of the Du Mortier Calibration algorithm for ground-based spectrometer. |
title_sort |
variation over time of the du mortier calibration algorithm for ground-based spectrometer. |
publisher |
American-Eurasian Network for Scientific Information (AENSI) |
publishDate |
2016 |
url |
https://eprints.ums.edu.my/id/eprint/18493/1/Variation%20Over%20Time%20of%20the%20Du%20Mortier%20Calibration%20Algorithm%20for%20Ground.pdf https://eprints.ums.edu.my/id/eprint/18493/ |
_version_ |
1760229453328285696 |
score |
13.211869 |