Analytical assessment of the behaviour of extended end plate connection

Steel frame structure with beams and columns was become I conventional building structure in construction world. In this study, one out of eight specimens from previous experimental which is specimen FS1a was modelled and simulated using Finite Element Method (FEM) which is ABAQUS/CAE Version 6.10...

Full description

Saved in:
Bibliographic Details
Main Author: Nur Fatin Zulaikha, Halijan
Format: Undergraduates Project Papers
Language:English
Published: 2014
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9379/1/NOOR%20FATIN%20ZULAIKHA%20BINTI%20HALIJAN.PDF
http://umpir.ump.edu.my/id/eprint/9379/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.9379
record_format eprints
spelling my.ump.umpir.93792021-07-16T00:54:00Z http://umpir.ump.edu.my/id/eprint/9379/ Analytical assessment of the behaviour of extended end plate connection Nur Fatin Zulaikha, Halijan TA Engineering (General). Civil engineering (General) Steel frame structure with beams and columns was become I conventional building structure in construction world. In this study, one out of eight specimens from previous experimental which is specimen FS1a was modelled and simulated using Finite Element Method (FEM) which is ABAQUS/CAE Version 6.10 under static loading. The specimen was model to determine the failure mode at the end plate besides to understand the behaviour of the extended endplate connection. This study was conducted to minimize the cost and time spends for the experiment. The failure modes involved in this analytical model was the weld failure of the assembly beam-end plate which is classified as Mode 1 failure that yielding of the end plate. As a result, moment rotation (M- 4) curve was obtained for analytical model in order to determine the capacity and behaviour of the extended end plate in terms of the resistance, stiffness and rotational capacity. The experimental results were used as a basis of comparison with the analytical results given by the component method of Eurocode 3 EN 1993-1-8. A good agreement was noticed between the analytical values and experimental values. Based on the results obtained, it can be concluded that in terms of rigidity, the classification boundaries of beam-to-column connection was rigid connection and the. extended end plate connection was designed as partial strength Comparisons of connection rotation capacity with the equivalent method in EurOcode 3 EN 1993-1-8 show that the end plate has an adequate rotation capacity for plastic analysis. 2014-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9379/1/NOOR%20FATIN%20ZULAIKHA%20BINTI%20HALIJAN.PDF Nur Fatin Zulaikha, Halijan (2014) Analytical assessment of the behaviour of extended end plate connection. Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Nur Fatin Zulaikha, Halijan
Analytical assessment of the behaviour of extended end plate connection
description Steel frame structure with beams and columns was become I conventional building structure in construction world. In this study, one out of eight specimens from previous experimental which is specimen FS1a was modelled and simulated using Finite Element Method (FEM) which is ABAQUS/CAE Version 6.10 under static loading. The specimen was model to determine the failure mode at the end plate besides to understand the behaviour of the extended endplate connection. This study was conducted to minimize the cost and time spends for the experiment. The failure modes involved in this analytical model was the weld failure of the assembly beam-end plate which is classified as Mode 1 failure that yielding of the end plate. As a result, moment rotation (M- 4) curve was obtained for analytical model in order to determine the capacity and behaviour of the extended end plate in terms of the resistance, stiffness and rotational capacity. The experimental results were used as a basis of comparison with the analytical results given by the component method of Eurocode 3 EN 1993-1-8. A good agreement was noticed between the analytical values and experimental values. Based on the results obtained, it can be concluded that in terms of rigidity, the classification boundaries of beam-to-column connection was rigid connection and the. extended end plate connection was designed as partial strength Comparisons of connection rotation capacity with the equivalent method in EurOcode 3 EN 1993-1-8 show that the end plate has an adequate rotation capacity for plastic analysis.
format Undergraduates Project Papers
author Nur Fatin Zulaikha, Halijan
author_facet Nur Fatin Zulaikha, Halijan
author_sort Nur Fatin Zulaikha, Halijan
title Analytical assessment of the behaviour of extended end plate connection
title_short Analytical assessment of the behaviour of extended end plate connection
title_full Analytical assessment of the behaviour of extended end plate connection
title_fullStr Analytical assessment of the behaviour of extended end plate connection
title_full_unstemmed Analytical assessment of the behaviour of extended end plate connection
title_sort analytical assessment of the behaviour of extended end plate connection
publishDate 2014
url http://umpir.ump.edu.my/id/eprint/9379/1/NOOR%20FATIN%20ZULAIKHA%20BINTI%20HALIJAN.PDF
http://umpir.ump.edu.my/id/eprint/9379/
_version_ 1706957205134114816
score 13.214268