Non-invasive Process Tomography in Chemical Mixtures – A Review

Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mi...

Full description

Saved in:
Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Ruzairi, Abdul Rahim, Mohd Hafiz, Fazalul Rahiman, Suzanna, Ridzuan Aw, Fazlul Rahman, Mohd Yunus, Chiew, Loon Goh, Herlina, Abdul Rahim, Leow, Pei Ling
Format: Article
Language:English
Published: Elsevier Ltd 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf
http://umpir.ump.edu.my/id/eprint/9117/
http://dx.doi.org/10.1016/j.snb.2014.12.103
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.9117
record_format eprints
spelling my.ump.umpir.91172018-02-14T01:56:07Z http://umpir.ump.edu.my/id/eprint/9117/ Non-invasive Process Tomography in Chemical Mixtures – A Review Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Chiew, Loon Goh Herlina, Abdul Rahim Leow, Pei Ling TK Electrical engineering. Electronics Nuclear engineering Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid–liquid, liquid–solid and liquid–gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed. Elsevier Ltd 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf Yasmin, Abdul Wahab and Ruzairi, Abdul Rahim and Mohd Hafiz, Fazalul Rahiman and Suzanna, Ridzuan Aw and Fazlul Rahman, Mohd Yunus and Chiew, Loon Goh and Herlina, Abdul Rahim and Leow, Pei Ling (2015) Non-invasive Process Tomography in Chemical Mixtures – A Review. Sensors and Actuators B: Chemical, 210. pp. 602-617. ISSN 0925-4005 http://dx.doi.org/10.1016/j.snb.2014.12.103 DOI: 10.1016/j.snb.2014.12.103
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Chiew, Loon Goh
Herlina, Abdul Rahim
Leow, Pei Ling
Non-invasive Process Tomography in Chemical Mixtures – A Review
description Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid–liquid, liquid–solid and liquid–gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed.
format Article
author Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Chiew, Loon Goh
Herlina, Abdul Rahim
Leow, Pei Ling
author_facet Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Chiew, Loon Goh
Herlina, Abdul Rahim
Leow, Pei Ling
author_sort Yasmin, Abdul Wahab
title Non-invasive Process Tomography in Chemical Mixtures – A Review
title_short Non-invasive Process Tomography in Chemical Mixtures – A Review
title_full Non-invasive Process Tomography in Chemical Mixtures – A Review
title_fullStr Non-invasive Process Tomography in Chemical Mixtures – A Review
title_full_unstemmed Non-invasive Process Tomography in Chemical Mixtures – A Review
title_sort non-invasive process tomography in chemical mixtures – a review
publisher Elsevier Ltd
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf
http://umpir.ump.edu.my/id/eprint/9117/
http://dx.doi.org/10.1016/j.snb.2014.12.103
_version_ 1643666043085783040
score 13.160551