Analysis of heat gain against cooling capacity at occupied building

This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of Block W when it’s fully occupied. The second objective of this project is to compare the calculated heat gain again...

Full description

Saved in:
Bibliographic Details
Main Author: Koh, Kelvin
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/904/1/03.Analysis%20of%20heat%20gain%20against%20cooling%20capacity%20at%20occupied%20building.pdf
http://umpir.ump.edu.my/id/eprint/904/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.904
record_format eprints
spelling my.ump.umpir.9042023-04-05T03:00:36Z http://umpir.ump.edu.my/id/eprint/904/ Analysis of heat gain against cooling capacity at occupied building Koh, Kelvin TJ Mechanical engineering and machinery This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of Block W when it’s fully occupied. The second objective of this project is to compare the calculated heat gain against the existing cooling capacity. In this project, Block W, UMP was chosen as the case study. The floor plan of Block W is first studied to review the building specifications. The building specification is used in the calculation of heat gain, and therefore to identify the cooling load required for Block W. When Block W is fully occupied, the number of occupant will be around 1500 people. There are two types of air-conditioning system used in Block W which are split unit and air handling unit and the total existing cooling load is observed to be 852.74 kW. The peak heat gain is calculated as 1172.43 kW using Cooling Load Factor/ Cooling Load Temperature Difference (CLF/CLTD) method at 3pm. Therefore, the existing cooling load is observed to be undersized in design. However, the peak heat gain will only happen occasionally throughout the year. In order to overcome the undersized design cooling capacity problem, the cooling capacity should increase 27.3%. 2009-11 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/904/1/03.Analysis%20of%20heat%20gain%20against%20cooling%20capacity%20at%20occupied%20building.pdf Koh, Kelvin (2009) Analysis of heat gain against cooling capacity at occupied building. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Koh, Kelvin
Analysis of heat gain against cooling capacity at occupied building
description This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of Block W when it’s fully occupied. The second objective of this project is to compare the calculated heat gain against the existing cooling capacity. In this project, Block W, UMP was chosen as the case study. The floor plan of Block W is first studied to review the building specifications. The building specification is used in the calculation of heat gain, and therefore to identify the cooling load required for Block W. When Block W is fully occupied, the number of occupant will be around 1500 people. There are two types of air-conditioning system used in Block W which are split unit and air handling unit and the total existing cooling load is observed to be 852.74 kW. The peak heat gain is calculated as 1172.43 kW using Cooling Load Factor/ Cooling Load Temperature Difference (CLF/CLTD) method at 3pm. Therefore, the existing cooling load is observed to be undersized in design. However, the peak heat gain will only happen occasionally throughout the year. In order to overcome the undersized design cooling capacity problem, the cooling capacity should increase 27.3%.
format Undergraduates Project Papers
author Koh, Kelvin
author_facet Koh, Kelvin
author_sort Koh, Kelvin
title Analysis of heat gain against cooling capacity at occupied building
title_short Analysis of heat gain against cooling capacity at occupied building
title_full Analysis of heat gain against cooling capacity at occupied building
title_fullStr Analysis of heat gain against cooling capacity at occupied building
title_full_unstemmed Analysis of heat gain against cooling capacity at occupied building
title_sort analysis of heat gain against cooling capacity at occupied building
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/904/1/03.Analysis%20of%20heat%20gain%20against%20cooling%20capacity%20at%20occupied%20building.pdf
http://umpir.ump.edu.my/id/eprint/904/
_version_ 1762392380751740928
score 13.18916