Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger

This paper deals with experimental determination of convective heat transfer coefficient in a counter flow double pipe heat exchanger using water based TiO ZnO nanofluids with 0.002% & 0.004% volume concentrations. Experiments are 2, conducted at various Reynolds numbers ranging from 1600 to 610...

Full description

Saved in:
Bibliographic Details
Main Authors: Ramaraju, Ramgopal Varma, M. Chandra, Sekhara Reddy, Veeredhi, Vasudeva Rao
Format: Article
Language:English
Published: 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/8196/1/EXPERIMENTAL_INVESTIGATION_OF_RELATIVE_PERFORMANCE_OF_WATER_BASED_TiO_AND_ZnO_NANOFLUIDS_IN_A__DOUBLE_PIPE_HEAT_EXCHANGER.pdf
http://umpir.ump.edu.my/id/eprint/8196/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.8196
record_format eprints
spelling my.ump.umpir.81962015-07-06T06:03:29Z http://umpir.ump.edu.my/id/eprint/8196/ Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger Ramaraju, Ramgopal Varma M. Chandra, Sekhara Reddy Veeredhi, Vasudeva Rao TJ Mechanical engineering and machinery This paper deals with experimental determination of convective heat transfer coefficient in a counter flow double pipe heat exchanger using water based TiO ZnO nanofluids with 0.002% & 0.004% volume concentrations. Experiments are 2, conducted at various Reynolds numbers ranging from 1600 to 6100. From the experimental results it is found that heat transfer coefficient increases with increase of volume concentration of nanoparticles as well as Reynolds number. Enhancement of heat transfer coefficient between nanofluids with 0.002% volume concentration of TiO ZnO and the 2, inner walls of copper tube in a double pipe heat exchanger increased up to 30.37% and 57.31% respectively. The enhancements are as high as 66.12% and 78.30% when the volume concentration is 0.004% of TiO and ZnO 2 respectively for same set of operating conditions when compared to pure water at Reynolds number 6100. The experimental results are presented in graphical form. The variation of heat transfer coefficient in both dimensional and non-dimensional form are presented as a function of Reynolds number for different volume concentrations of nanofluids. The effectiveness of heat exchanger is also presented as a function of volume concentration of nanofluids. 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8196/1/EXPERIMENTAL_INVESTIGATION_OF_RELATIVE_PERFORMANCE_OF_WATER_BASED_TiO_AND_ZnO_NANOFLUIDS_IN_A__DOUBLE_PIPE_HEAT_EXCHANGER.pdf Ramaraju, Ramgopal Varma and M. Chandra, Sekhara Reddy and Veeredhi, Vasudeva Rao (2015) Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger. Journal on Mechanical Engineering,, 5 (1). pp. 6-11.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Ramaraju, Ramgopal Varma
M. Chandra, Sekhara Reddy
Veeredhi, Vasudeva Rao
Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
description This paper deals with experimental determination of convective heat transfer coefficient in a counter flow double pipe heat exchanger using water based TiO ZnO nanofluids with 0.002% & 0.004% volume concentrations. Experiments are 2, conducted at various Reynolds numbers ranging from 1600 to 6100. From the experimental results it is found that heat transfer coefficient increases with increase of volume concentration of nanoparticles as well as Reynolds number. Enhancement of heat transfer coefficient between nanofluids with 0.002% volume concentration of TiO ZnO and the 2, inner walls of copper tube in a double pipe heat exchanger increased up to 30.37% and 57.31% respectively. The enhancements are as high as 66.12% and 78.30% when the volume concentration is 0.004% of TiO and ZnO 2 respectively for same set of operating conditions when compared to pure water at Reynolds number 6100. The experimental results are presented in graphical form. The variation of heat transfer coefficient in both dimensional and non-dimensional form are presented as a function of Reynolds number for different volume concentrations of nanofluids. The effectiveness of heat exchanger is also presented as a function of volume concentration of nanofluids.
format Article
author Ramaraju, Ramgopal Varma
M. Chandra, Sekhara Reddy
Veeredhi, Vasudeva Rao
author_facet Ramaraju, Ramgopal Varma
M. Chandra, Sekhara Reddy
Veeredhi, Vasudeva Rao
author_sort Ramaraju, Ramgopal Varma
title Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
title_short Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
title_full Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
title_fullStr Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
title_full_unstemmed Experimental Investigation of Relative Performance of Water Based Tio and Zno Nanofluids in a Double Pipe Heat Exchanger
title_sort experimental investigation of relative performance of water based tio and zno nanofluids in a double pipe heat exchanger
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/8196/1/EXPERIMENTAL_INVESTIGATION_OF_RELATIVE_PERFORMANCE_OF_WATER_BASED_TiO_AND_ZnO_NANOFLUIDS_IN_A__DOUBLE_PIPE_HEAT_EXCHANGER.pdf
http://umpir.ump.edu.my/id/eprint/8196/
_version_ 1643665808403988480
score 13.160551