Numerical investigation on the effect of different strut angle to the cerebral aneurysm

The objective of this study was to determine the correlation of stent strut angle to blood flow and also to determine the flow behavior in stented aneurysm. The computational fluid dynamics was applied to access the changes of velocity and pressure in aneurysms. For this study, there are five stent...

Full description

Saved in:
Bibliographic Details
Main Author: Noor Harliana, A. Hamid
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/818/1/Noor_Harliana_A._Hamid.pdf
http://umpir.ump.edu.my/id/eprint/818/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.818
record_format eprints
spelling my.ump.umpir.8182021-06-18T08:31:52Z http://umpir.ump.edu.my/id/eprint/818/ Numerical investigation on the effect of different strut angle to the cerebral aneurysm Noor Harliana, A. Hamid TA Engineering (General). Civil engineering (General) The objective of this study was to determine the correlation of stent strut angle to blood flow and also to determine the flow behavior in stented aneurysm. The computational fluid dynamics was applied to access the changes of velocity and pressure in aneurysms. For this study, there are five stent with the same design but different in strut angle of the stent. The strut angle used in this study was 30°, 35°, 35°, 40°, 45° and 50°. By using 30° of strut angle as the control model and the other angle as the experimental model, there are referred to as type I, type II, type III and type IV. The simulation of the model was studied under incompressible, Newtonian, viscous and non-pulsatile condition. The results for all stents analyzed in the current study showed that the stent with higher angle are more efficient than stent with lower angle. The minimum velocity increased with the implacement of stent type IV which is the higher strut angle. Meanwhile, for the pressure distribution of all type of stents indicate that lowest peak pressure obtained by stent type III. Therefore, strut angle used should be suitable to satisfy the requirement of lowest peak pressure and highest minimum velocity. So, the strut angle has to be maintained within a certain range, which varies from 40° to 45°. Finally, the correlation obtained from this numerical result could be used to investigate the pressure distribution around the aneurysms. 2009-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/818/1/Noor_Harliana_A._Hamid.pdf Noor Harliana, A. Hamid (2009) Numerical investigation on the effect of different strut angle to the cerebral aneurysm. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Noor Harliana, A. Hamid
Numerical investigation on the effect of different strut angle to the cerebral aneurysm
description The objective of this study was to determine the correlation of stent strut angle to blood flow and also to determine the flow behavior in stented aneurysm. The computational fluid dynamics was applied to access the changes of velocity and pressure in aneurysms. For this study, there are five stent with the same design but different in strut angle of the stent. The strut angle used in this study was 30°, 35°, 35°, 40°, 45° and 50°. By using 30° of strut angle as the control model and the other angle as the experimental model, there are referred to as type I, type II, type III and type IV. The simulation of the model was studied under incompressible, Newtonian, viscous and non-pulsatile condition. The results for all stents analyzed in the current study showed that the stent with higher angle are more efficient than stent with lower angle. The minimum velocity increased with the implacement of stent type IV which is the higher strut angle. Meanwhile, for the pressure distribution of all type of stents indicate that lowest peak pressure obtained by stent type III. Therefore, strut angle used should be suitable to satisfy the requirement of lowest peak pressure and highest minimum velocity. So, the strut angle has to be maintained within a certain range, which varies from 40° to 45°. Finally, the correlation obtained from this numerical result could be used to investigate the pressure distribution around the aneurysms.
format Undergraduates Project Papers
author Noor Harliana, A. Hamid
author_facet Noor Harliana, A. Hamid
author_sort Noor Harliana, A. Hamid
title Numerical investigation on the effect of different strut angle to the cerebral aneurysm
title_short Numerical investigation on the effect of different strut angle to the cerebral aneurysm
title_full Numerical investigation on the effect of different strut angle to the cerebral aneurysm
title_fullStr Numerical investigation on the effect of different strut angle to the cerebral aneurysm
title_full_unstemmed Numerical investigation on the effect of different strut angle to the cerebral aneurysm
title_sort numerical investigation on the effect of different strut angle to the cerebral aneurysm
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/818/1/Noor_Harliana_A._Hamid.pdf
http://umpir.ump.edu.my/id/eprint/818/
_version_ 1703960614969278464
score 13.214268