Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process

This research is about enhancement of PCA-based fault detection system through utilizing dissimilarity matrix. Nowadays, the chemical process industry is highly based on the non-linear relationships between measured variables. However, the conventional PCA-based MSPC is no longer effective because i...

Full description

Saved in:
Bibliographic Details
Main Author: Nur Afifah, Hassan
Format: Undergraduates Project Papers
Language:English
Published: 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/7163/1/Enhancement_of_PCA.pdf
http://umpir.ump.edu.my/id/eprint/7163/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.7163
record_format eprints
spelling my.ump.umpir.71632021-06-08T06:47:15Z http://umpir.ump.edu.my/id/eprint/7163/ Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process Nur Afifah, Hassan QA Mathematics This research is about enhancement of PCA-based fault detection system through utilizing dissimilarity matrix. Nowadays, the chemical process industry is highly based on the non-linear relationships between measured variables. However, the conventional PCA-based MSPC is no longer effective because it only valid for the linear relationships between measured variables. Due in order to solve this problem, the technique of dissimilarity matrix is used in multivariate statistical process control as alternative technique which models the non-linear process and can improve the process monitoring performance. The conventional PCA system was run and the dissimilarity system was developed and lastly the monitoring performance in each technique were compared and analysed to achieve aims of this research. This research is to be done by using Matlab software. The findings of this study are illustrated in the form of Hotelling’s T2 and Squared Prediction Errors (SPE) monitoring statistics to be analysed. As a conclusion, the dissimilarity system is comparable to the conventional method. Thus can be the other alternative ways in the process monitoring performance. Finally, it is recommended to use data from other chemical processing systems for more concrete justification of the new technique. 2013 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/7163/1/Enhancement_of_PCA.pdf Nur Afifah, Hassan (2013) Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process. Faculty of Chemical & Natural Resources Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic QA Mathematics
spellingShingle QA Mathematics
Nur Afifah, Hassan
Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
description This research is about enhancement of PCA-based fault detection system through utilizing dissimilarity matrix. Nowadays, the chemical process industry is highly based on the non-linear relationships between measured variables. However, the conventional PCA-based MSPC is no longer effective because it only valid for the linear relationships between measured variables. Due in order to solve this problem, the technique of dissimilarity matrix is used in multivariate statistical process control as alternative technique which models the non-linear process and can improve the process monitoring performance. The conventional PCA system was run and the dissimilarity system was developed and lastly the monitoring performance in each technique were compared and analysed to achieve aims of this research. This research is to be done by using Matlab software. The findings of this study are illustrated in the form of Hotelling’s T2 and Squared Prediction Errors (SPE) monitoring statistics to be analysed. As a conclusion, the dissimilarity system is comparable to the conventional method. Thus can be the other alternative ways in the process monitoring performance. Finally, it is recommended to use data from other chemical processing systems for more concrete justification of the new technique.
format Undergraduates Project Papers
author Nur Afifah, Hassan
author_facet Nur Afifah, Hassan
author_sort Nur Afifah, Hassan
title Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
title_short Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
title_full Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
title_fullStr Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
title_full_unstemmed Enhancement of PCA-based fault detection system through utilising dissimilarity matrix for continuous-based process
title_sort enhancement of pca-based fault detection system through utilising dissimilarity matrix for continuous-based process
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/7163/1/Enhancement_of_PCA.pdf
http://umpir.ump.edu.my/id/eprint/7163/
_version_ 1702170064987357184
score 13.209306