Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces

Gait data collection from overweight individuals walking on irregular surfaces is a challenging task that can be addressed using inertial measurement unit (IMU) sensors. However, it is unclear how many IMUs are needed, particularly when body attachment locations are not standardized. In this study,...

Full description

Saved in:
Bibliographic Details
Main Authors: Sikandar, Tasriva, Rabbi, Mohammad Fazle, Kamarul Hawari, Ghazali, Altwijri, Omar, Almijalli, Mohammed, Ahamed, Nizam Uddin
Format: Article
Language:English
English
Published: Nature Research 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/42900/1/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify.pdf
http://umpir.ump.edu.my/id/eprint/42900/2/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify%20significant%20variations%20in%20walk%20patterns%20of%20overweight%20individuals%20walking%20on%20irregular%20surfaces_abs.pdf
http://umpir.ump.edu.my/id/eprint/42900/
https://doi.org/10.1038/s41598-023-43428-9
https://doi.org/10.1038/s41598-023-43428-9
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.42900
record_format eprints
spelling my.ump.umpir.429002025-01-07T05:01:37Z http://umpir.ump.edu.my/id/eprint/42900/ Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces Sikandar, Tasriva Rabbi, Mohammad Fazle Kamarul Hawari, Ghazali Altwijri, Omar Almijalli, Mohammed Ahamed, Nizam Uddin T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Gait data collection from overweight individuals walking on irregular surfaces is a challenging task that can be addressed using inertial measurement unit (IMU) sensors. However, it is unclear how many IMUs are needed, particularly when body attachment locations are not standardized. In this study, we analysed data collected from six body locations, including the torso, upper and lower limbs, to determine which locations exhibit significant variation across different real-world irregular surfaces. We then used deep learning method to verify whether the IMU data recorded from the identified body locations could classify walk patterns across the surfaces. Our results revealed two combinations of body locations, including the thigh and shank (i.e., the left and right shank, and the right thigh and right shank), from which IMU data should be collected to accurately classify walking patterns over real-world irregular surfaces (with classification accuracies of 97.24 and 95.87%, respectively). Our findings suggest that the identified numbers and locations of IMUs could potentially reduce the amount of data recorded and processed to develop a fall prevention system for overweight individuals. Nature Research 2023-12 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/42900/1/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify.pdf pdf en http://umpir.ump.edu.my/id/eprint/42900/2/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify%20significant%20variations%20in%20walk%20patterns%20of%20overweight%20individuals%20walking%20on%20irregular%20surfaces_abs.pdf Sikandar, Tasriva and Rabbi, Mohammad Fazle and Kamarul Hawari, Ghazali and Altwijri, Omar and Almijalli, Mohammed and Ahamed, Nizam Uddin (2023) Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces. Scientific Reports, 13 (16177). pp. 1-14. ISSN 2045-2322. (Published) https://doi.org/10.1038/s41598-023-43428-9 https://doi.org/10.1038/s41598-023-43428-9
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Sikandar, Tasriva
Rabbi, Mohammad Fazle
Kamarul Hawari, Ghazali
Altwijri, Omar
Almijalli, Mohammed
Ahamed, Nizam Uddin
Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
description Gait data collection from overweight individuals walking on irregular surfaces is a challenging task that can be addressed using inertial measurement unit (IMU) sensors. However, it is unclear how many IMUs are needed, particularly when body attachment locations are not standardized. In this study, we analysed data collected from six body locations, including the torso, upper and lower limbs, to determine which locations exhibit significant variation across different real-world irregular surfaces. We then used deep learning method to verify whether the IMU data recorded from the identified body locations could classify walk patterns across the surfaces. Our results revealed two combinations of body locations, including the thigh and shank (i.e., the left and right shank, and the right thigh and right shank), from which IMU data should be collected to accurately classify walking patterns over real-world irregular surfaces (with classification accuracies of 97.24 and 95.87%, respectively). Our findings suggest that the identified numbers and locations of IMUs could potentially reduce the amount of data recorded and processed to develop a fall prevention system for overweight individuals.
format Article
author Sikandar, Tasriva
Rabbi, Mohammad Fazle
Kamarul Hawari, Ghazali
Altwijri, Omar
Almijalli, Mohammed
Ahamed, Nizam Uddin
author_facet Sikandar, Tasriva
Rabbi, Mohammad Fazle
Kamarul Hawari, Ghazali
Altwijri, Omar
Almijalli, Mohammed
Ahamed, Nizam Uddin
author_sort Sikandar, Tasriva
title Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
title_short Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
title_full Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
title_fullStr Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
title_full_unstemmed Minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
title_sort minimum number of inertial measurement units needed to identify signiicant variations in walk patterns of overweight individuals walking on irregular surfaces
publisher Nature Research
publishDate 2023
url http://umpir.ump.edu.my/id/eprint/42900/1/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify.pdf
http://umpir.ump.edu.my/id/eprint/42900/2/Minimum%20number%20of%20inertial%20measurement%20units%20needed%20to%20identify%20significant%20variations%20in%20walk%20patterns%20of%20overweight%20individuals%20walking%20on%20irregular%20surfaces_abs.pdf
http://umpir.ump.edu.my/id/eprint/42900/
https://doi.org/10.1038/s41598-023-43428-9
https://doi.org/10.1038/s41598-023-43428-9
_version_ 1822924894470406144
score 13.235796