Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies
Aged photovoltaic panels commonly have hotspots, which can result in large power losses. In this study, hotspot creation in solar panels is investigated and the reasons for it are identified and outlines many methods for preventing the establishment of pre-hotspots and investigates the findings of e...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/41840/1/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot.pdf http://umpir.ump.edu.my/id/eprint/41840/2/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot%20conditions_A%20comparison%20of%20different%20interconnection%20topologies_ABS.pdf http://umpir.ump.edu.my/id/eprint/41840/ https://doi.org/10.1109/STI59863.2023.10464796 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.41840 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.418402024-08-30T00:11:41Z http://umpir.ump.edu.my/id/eprint/41840/ Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies Al Mansur, Ahmed Alam, Md Sabbir Leyon, Shaquar Islam Sultana, Zinat Islam, Md Imamul Haider, Chowdhury Shajjad Tohid, Sabbir Hasan Rahman, Md. Mostafizur Alom, Md Shahin Sultana, Shafia Ustun, Taha Selim T Technology (General) TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering Aged photovoltaic panels commonly have hotspots, which can result in large power losses. In this study, hotspot creation in solar panels is investigated and the reasons for it are identified and outlines many methods for preventing the establishment of pre-hotspots and investigates the findings of experimental research. The power output, voltage, current, irradiance, and loss percentage for five configurations of solar array designs have been investigated in this work using a 4×4 array consisting of 16 PV modules that are 4 years old. Experimentally it can be possible to recover the output power by changing interconnections such as SP, TCT, LD, BL, and HC. The output demonstrates that the loss of SP, TCT, LD, BL, and HC was 8.81 %, 4.06%, 0.06%, 5.37%, and 3.13% respectively. 4.286% is the average loss percentage for all five configurations. The recoverable power of the TCT, LD, BL, and HC concerning SP was 5.21 %, 9.73%, 3.77%, and 6.24% respectively. The findings demonstrate the LD configuration has the lowest percentage of power loss, and the maximum loss has been obtained by the SP configuration. Institute of Electrical and Electronics Engineers Inc. 2023 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41840/1/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot.pdf pdf en http://umpir.ump.edu.my/id/eprint/41840/2/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot%20conditions_A%20comparison%20of%20different%20interconnection%20topologies_ABS.pdf Al Mansur, Ahmed and Alam, Md Sabbir and Leyon, Shaquar Islam and Sultana, Zinat and Islam, Md Imamul and Haider, Chowdhury Shajjad and Tohid, Sabbir Hasan and Rahman, Md. Mostafizur and Alom, Md Shahin and Sultana, Shafia and Ustun, Taha Selim (2023) Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies. In: 2023 5th International Conference on Sustainable Technologies for Industry 5.0, STI 2023. 5th International Conference on Sustainable Technologies for Industry 5.0, STI 2023 , 9-10 December 2023 , Dhaka. pp. 1-5. (198386). ISBN 979-835039429-0 (Published) https://doi.org/10.1109/STI59863.2023.10464796 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering Al Mansur, Ahmed Alam, Md Sabbir Leyon, Shaquar Islam Sultana, Zinat Islam, Md Imamul Haider, Chowdhury Shajjad Tohid, Sabbir Hasan Rahman, Md. Mostafizur Alom, Md Shahin Sultana, Shafia Ustun, Taha Selim Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
description |
Aged photovoltaic panels commonly have hotspots, which can result in large power losses. In this study, hotspot creation in solar panels is investigated and the reasons for it are identified and outlines many methods for preventing the establishment of pre-hotspots and investigates the findings of experimental research. The power output, voltage, current, irradiance, and loss percentage for five configurations of solar array designs have been investigated in this work using a 4×4 array consisting of 16 PV modules that are 4 years old. Experimentally it can be possible to recover the output power by changing interconnections such as SP, TCT, LD, BL, and HC. The output demonstrates that the loss of SP, TCT, LD, BL, and HC was 8.81 %, 4.06%, 0.06%, 5.37%, and 3.13% respectively. 4.286% is the average loss percentage for all five configurations. The recoverable power of the TCT, LD, BL, and HC concerning SP was 5.21 %, 9.73%, 3.77%, and 6.24% respectively. The findings demonstrate the LD configuration has the lowest percentage of power loss, and the maximum loss has been obtained by the SP configuration. |
format |
Conference or Workshop Item |
author |
Al Mansur, Ahmed Alam, Md Sabbir Leyon, Shaquar Islam Sultana, Zinat Islam, Md Imamul Haider, Chowdhury Shajjad Tohid, Sabbir Hasan Rahman, Md. Mostafizur Alom, Md Shahin Sultana, Shafia Ustun, Taha Selim |
author_facet |
Al Mansur, Ahmed Alam, Md Sabbir Leyon, Shaquar Islam Sultana, Zinat Islam, Md Imamul Haider, Chowdhury Shajjad Tohid, Sabbir Hasan Rahman, Md. Mostafizur Alom, Md Shahin Sultana, Shafia Ustun, Taha Selim |
author_sort |
Al Mansur, Ahmed |
title |
Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
title_short |
Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
title_full |
Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
title_fullStr |
Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
title_full_unstemmed |
Energy enhancement of aged photovoltaic array under hotspot conditions : A comparison of different interconnection topologies |
title_sort |
energy enhancement of aged photovoltaic array under hotspot conditions : a comparison of different interconnection topologies |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
url |
http://umpir.ump.edu.my/id/eprint/41840/1/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot.pdf http://umpir.ump.edu.my/id/eprint/41840/2/Energy%20enhancement%20of%20aged%20photovoltaic%20array%20under%20hotspot%20conditions_A%20comparison%20of%20different%20interconnection%20topologies_ABS.pdf http://umpir.ump.edu.my/id/eprint/41840/ https://doi.org/10.1109/STI59863.2023.10464796 |
_version_ |
1822924591903801344 |
score |
13.236483 |