Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program

Patient under methadone flexi dispensing (MFlex) program are required to perform blood tests like lipid profile. To verify the patient does have a lipid disorder, a doctor analyses 3 parameters such as cholesterol, HDL cholesterol, and LDL cholesterol. However, the present system lacks a robust ecol...

Full description

Saved in:
Bibliographic Details
Main Authors: S. N. A. M., Zaini, Mohd Yazid, Abu, Nur Najmiyah, Jaafar, S. K. M., Saad
Format: Article
Language:English
Published: Malaysian Technical Universities Network (MTUN) 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/40213/1/publication10-RDU220104.pdf
http://umpir.ump.edu.my/id/eprint/40213/
https://jet.utem.edu.my/jet/article/view/6470
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.40213
record_format eprints
spelling my.ump.umpir.402132024-02-27T07:49:13Z http://umpir.ump.edu.my/id/eprint/40213/ Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program S. N. A. M., Zaini Mohd Yazid, Abu Nur Najmiyah, Jaafar S. K. M., Saad T Technology (General) TJ Mechanical engineering and machinery Patient under methadone flexi dispensing (MFlex) program are required to perform blood tests like lipid profile. To verify the patient does have a lipid disorder, a doctor analyses 3 parameters such as cholesterol, HDL cholesterol, and LDL cholesterol. However, the present system lacks a robust ecology for categorization and optimization due to imprecise measuring methods and a lack of rationale for major elements that impact diagnostic accuracy. The goal is to implement the Mahalanobis-Taguchi system (MTS) into the MFlex programme. The data was acquired at the Bandar Pekan clinic and included 34 lipid profile measures. For classification and optimization, two categories of MTS techniques are being used, which are RT-Method and T-Method. As a result of the lipid profile analysis, the healthy Mahalanobis distance (MD) is 1.0000, whereas the unhealthy MD is 79.5876. Positive contributions are made by parameters 1, 3, 4, 6, 7, 8, 9, 11, 12, 17, 18, 23, 26, 27, 28, 30, 31, 33, and 34. 15 unknown samples were diagnosed with varying degrees of positive and negative contribution to obtain a smaller MD. The best recommended way has been typed 5 from overall 6 modifications. Finally, the pharmacist acknowledged that MTS could tackle the issue of MFlex programme categorization. Malaysian Technical Universities Network (MTUN) 2023 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/40213/1/publication10-RDU220104.pdf S. N. A. M., Zaini and Mohd Yazid, Abu and Nur Najmiyah, Jaafar and S. K. M., Saad (2023) Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program. Journal of Engineering and Technology, 14 (2). pp. 45-71. ISSN 2180-3811. (Published) https://jet.utem.edu.my/jet/article/view/6470
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
S. N. A. M., Zaini
Mohd Yazid, Abu
Nur Najmiyah, Jaafar
S. K. M., Saad
Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
description Patient under methadone flexi dispensing (MFlex) program are required to perform blood tests like lipid profile. To verify the patient does have a lipid disorder, a doctor analyses 3 parameters such as cholesterol, HDL cholesterol, and LDL cholesterol. However, the present system lacks a robust ecology for categorization and optimization due to imprecise measuring methods and a lack of rationale for major elements that impact diagnostic accuracy. The goal is to implement the Mahalanobis-Taguchi system (MTS) into the MFlex programme. The data was acquired at the Bandar Pekan clinic and included 34 lipid profile measures. For classification and optimization, two categories of MTS techniques are being used, which are RT-Method and T-Method. As a result of the lipid profile analysis, the healthy Mahalanobis distance (MD) is 1.0000, whereas the unhealthy MD is 79.5876. Positive contributions are made by parameters 1, 3, 4, 6, 7, 8, 9, 11, 12, 17, 18, 23, 26, 27, 28, 30, 31, 33, and 34. 15 unknown samples were diagnosed with varying degrees of positive and negative contribution to obtain a smaller MD. The best recommended way has been typed 5 from overall 6 modifications. Finally, the pharmacist acknowledged that MTS could tackle the issue of MFlex programme categorization.
format Article
author S. N. A. M., Zaini
Mohd Yazid, Abu
Nur Najmiyah, Jaafar
S. K. M., Saad
author_facet S. N. A. M., Zaini
Mohd Yazid, Abu
Nur Najmiyah, Jaafar
S. K. M., Saad
author_sort S. N. A. M., Zaini
title Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
title_short Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
title_full Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
title_fullStr Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
title_full_unstemmed Application of MT method of Mahalanobis-Taguchi system in methadone flexi dispensing program
title_sort application of mt method of mahalanobis-taguchi system in methadone flexi dispensing program
publisher Malaysian Technical Universities Network (MTUN)
publishDate 2023
url http://umpir.ump.edu.my/id/eprint/40213/1/publication10-RDU220104.pdf
http://umpir.ump.edu.my/id/eprint/40213/
https://jet.utem.edu.my/jet/article/view/6470
_version_ 1822924127731712000