Air pollution monitoring system in semi enclosed building for agricultural sector

This article explains about the development of an optical sensor system to detect and measure ammonia emission in the agricultural field. At initial stage, an open path optical technique where a cylindrical chamber is used to detect low concentration of ammonia in the UV region. The methodology desc...

Full description

Saved in:
Bibliographic Details
Main Authors: S., Nurulain, M S, Najib, E., Lewis, M R, Salim, H., Manap
Format: Article
Language:English
Published: IOP Publishing 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/37865/1/Air%20pollution%20monitoring%20system%20in%20semi%20enclosed.pdf
http://umpir.ump.edu.my/id/eprint/37865/
https://iopscience.iop.org/article/10.1088/1742-6596/1706/1/012064
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.37865
record_format eprints
spelling my.ump.umpir.378652023-06-26T05:43:58Z http://umpir.ump.edu.my/id/eprint/37865/ Air pollution monitoring system in semi enclosed building for agricultural sector S., Nurulain M S, Najib E., Lewis M R, Salim H., Manap QC Physics This article explains about the development of an optical sensor system to detect and measure ammonia emission in the agricultural field. At initial stage, an open path optical technique where a cylindrical chamber is used to detect low concentration of ammonia in the UV region. The methodology describing the working principle of the sensor and the wavelengths combination technique to enhance the Lower Detection Limit of the measurement. The result demonstrates that the developed optical sensor is able to measure ammonia concentration at around 212 nm. It also shows that by combining intensities at 2 adjacent wavelengths, the Lower Detection Limit has been improved to 2.25 ppm and 1 s response time is retained. Then the system is tested to monitor ammonia pollution in the cattle barn in Tipperary, Ireland. It shows that the developed system is able to detect and measure very low ammonia concentration which is below 2 ppm. IOP Publishing 2020 Article PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/37865/1/Air%20pollution%20monitoring%20system%20in%20semi%20enclosed.pdf S., Nurulain and M S, Najib and E., Lewis and M R, Salim and H., Manap (2020) Air pollution monitoring system in semi enclosed building for agricultural sector. Journal of Physics: Conference series, 1706 (012064). ISSN 1742-6588 (print); 1742-6596 (online) https://iopscience.iop.org/article/10.1088/1742-6596/1706/1/012064 DOI 10.1088/1742-6596/1706/1/012064
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic QC Physics
spellingShingle QC Physics
S., Nurulain
M S, Najib
E., Lewis
M R, Salim
H., Manap
Air pollution monitoring system in semi enclosed building for agricultural sector
description This article explains about the development of an optical sensor system to detect and measure ammonia emission in the agricultural field. At initial stage, an open path optical technique where a cylindrical chamber is used to detect low concentration of ammonia in the UV region. The methodology describing the working principle of the sensor and the wavelengths combination technique to enhance the Lower Detection Limit of the measurement. The result demonstrates that the developed optical sensor is able to measure ammonia concentration at around 212 nm. It also shows that by combining intensities at 2 adjacent wavelengths, the Lower Detection Limit has been improved to 2.25 ppm and 1 s response time is retained. Then the system is tested to monitor ammonia pollution in the cattle barn in Tipperary, Ireland. It shows that the developed system is able to detect and measure very low ammonia concentration which is below 2 ppm.
format Article
author S., Nurulain
M S, Najib
E., Lewis
M R, Salim
H., Manap
author_facet S., Nurulain
M S, Najib
E., Lewis
M R, Salim
H., Manap
author_sort S., Nurulain
title Air pollution monitoring system in semi enclosed building for agricultural sector
title_short Air pollution monitoring system in semi enclosed building for agricultural sector
title_full Air pollution monitoring system in semi enclosed building for agricultural sector
title_fullStr Air pollution monitoring system in semi enclosed building for agricultural sector
title_full_unstemmed Air pollution monitoring system in semi enclosed building for agricultural sector
title_sort air pollution monitoring system in semi enclosed building for agricultural sector
publisher IOP Publishing
publishDate 2020
url http://umpir.ump.edu.my/id/eprint/37865/1/Air%20pollution%20monitoring%20system%20in%20semi%20enclosed.pdf
http://umpir.ump.edu.my/id/eprint/37865/
https://iopscience.iop.org/article/10.1088/1742-6596/1706/1/012064
_version_ 1769842532002299904
score 13.160551