Analysis on auger pump performance during handling high viscous liquid

Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferrin...

Full description

Saved in:
Bibliographic Details
Main Authors: Alisha, E., Najwa, N., Jamaludin, A. S., Razali, M. N. M., Saffe, S. N. M.
Format: Article
Language:English
Published: Penerbit UMP 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf
http://umpir.ump.edu.my/id/eprint/35685/
https://doi.org/10.15282/jmmst.v6i2.8564
https://doi.org/10.15282/jmmst.v6i2.8564
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.35685
record_format eprints
spelling my.ump.umpir.356852022-11-10T08:13:26Z http://umpir.ump.edu.my/id/eprint/35685/ Analysis on auger pump performance during handling high viscous liquid Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TS Manufactures Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid. Penerbit UMP 2022-09 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf Alisha, E. and Najwa, N. and Jamaludin, A. S. and Razali, M. N. M. and Saffe, S. N. M. (2022) Analysis on auger pump performance during handling high viscous liquid. Journal of Modern Manufacturing Systems and Technology (JMMST), 6 (2). pp. 48-54. ISSN 2636-9575 https://doi.org/10.15282/jmmst.v6i2.8564 https://doi.org/10.15282/jmmst.v6i2.8564
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TS Manufactures
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TS Manufactures
Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
Analysis on auger pump performance during handling high viscous liquid
description Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid.
format Article
author Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
author_facet Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
author_sort Alisha, E.
title Analysis on auger pump performance during handling high viscous liquid
title_short Analysis on auger pump performance during handling high viscous liquid
title_full Analysis on auger pump performance during handling high viscous liquid
title_fullStr Analysis on auger pump performance during handling high viscous liquid
title_full_unstemmed Analysis on auger pump performance during handling high viscous liquid
title_sort analysis on auger pump performance during handling high viscous liquid
publisher Penerbit UMP
publishDate 2022
url http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf
http://umpir.ump.edu.my/id/eprint/35685/
https://doi.org/10.15282/jmmst.v6i2.8564
https://doi.org/10.15282/jmmst.v6i2.8564
_version_ 1751536389954994176
score 13.214268