The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain
In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiff...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf http://umpir.ump.edu.my/id/eprint/34569/ https://doi.org/10.24425/ace.2022.140628 https://doi.org/10.24425/ace.2022.140628 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.34569 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.345692022-07-29T01:11:58Z http://umpir.ump.edu.my/id/eprint/34569/ The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain Nur Liza, Rahim Raftery, Gary Quenneville, Pierre Doh, Shu Ing Nabialek, Marcin Putra Jaya, Ramadhansyah Norlia, Mohamad Ibrahim Mohd Mustafa Al Bakri, Abdullah Śliwa, Agata TH Building construction In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiffness of each connection. In order to validate the Eurocode 5 stiffness equation, tests on 50 timber specimens (40 glued laminated timbers and 10 laminated veneer lumbers (LVL)) with steel plates were undertaken. The number of bolts was kept similar and the connector diameter, timber thickness, and wood density were varied. The results obtained in the experimental tests are compared with those obtained from the Eurocode 5 stiffness equation. From the analysis, it is signified that the stiffness equation specified in Eurocode 5 for bolted SWS connections does not adequately predict the initial stiffness. The results from Eurocode 5 stiffness equation are very far from the experimental values. The ratio of stiffness equation to experimental results ranges from 3.48 to 4.20, with the average at 3.77, where the equation overpredicted the experimental stiffness value for the connection. There is a need to consider or incorporated other parameters such as geometric configurations in Eurocode 5 stiffness equation to improve the ratio with the experimental data. Polish Academy of Sciences 2022 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf Nur Liza, Rahim and Raftery, Gary and Quenneville, Pierre and Doh, Shu Ing and Nabialek, Marcin and Putra Jaya, Ramadhansyah and Norlia, Mohamad Ibrahim and Mohd Mustafa Al Bakri, Abdullah and Śliwa, Agata (2022) The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain. Archives of Civil Engineering, 68 (2). pp. 37-50. ISSN 1230-2945 https://doi.org/10.24425/ace.2022.140628 https://doi.org/10.24425/ace.2022.140628 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TH Building construction |
spellingShingle |
TH Building construction Nur Liza, Rahim Raftery, Gary Quenneville, Pierre Doh, Shu Ing Nabialek, Marcin Putra Jaya, Ramadhansyah Norlia, Mohamad Ibrahim Mohd Mustafa Al Bakri, Abdullah Śliwa, Agata The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
description |
In Eurocode 5, the stiffness equation for bolted steel-wood-steel is stated as a function of wood density and fastener diameter only. In this research, an experimental study on various configurations of tested bolted steel-wood-steel (SWS) connections has been undertaken to predict the initial stiffness of each connection. In order to validate the Eurocode 5 stiffness equation, tests on 50 timber specimens (40 glued laminated timbers and 10 laminated veneer lumbers (LVL)) with steel plates were undertaken. The number of bolts was kept similar and the connector diameter, timber thickness, and wood density were varied. The results obtained in the experimental tests are compared with those obtained from the Eurocode 5 stiffness equation. From the analysis, it is signified that the stiffness equation specified in
Eurocode 5 for bolted SWS connections does not adequately predict the initial stiffness. The results from Eurocode 5 stiffness equation are very far from the experimental values. The ratio of stiffness equation to experimental results ranges from 3.48 to 4.20, with the average at 3.77, where the equation overpredicted the experimental stiffness value for the connection. There is a need to consider or incorporated
other parameters such as geometric configurations in Eurocode 5 stiffness equation to improve the ratio with the experimental data. |
format |
Article |
author |
Nur Liza, Rahim Raftery, Gary Quenneville, Pierre Doh, Shu Ing Nabialek, Marcin Putra Jaya, Ramadhansyah Norlia, Mohamad Ibrahim Mohd Mustafa Al Bakri, Abdullah Śliwa, Agata |
author_facet |
Nur Liza, Rahim Raftery, Gary Quenneville, Pierre Doh, Shu Ing Nabialek, Marcin Putra Jaya, Ramadhansyah Norlia, Mohamad Ibrahim Mohd Mustafa Al Bakri, Abdullah Śliwa, Agata |
author_sort |
Nur Liza, Rahim |
title |
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
title_short |
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
title_full |
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
title_fullStr |
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
title_full_unstemmed |
The Stiffness of Steel-Wood-Steel Connection Loaded Parallel to the Grain |
title_sort |
stiffness of steel-wood-steel connection loaded parallel to the grain |
publisher |
Polish Academy of Sciences |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/34569/1/The%20stiffness%20of%20steel-wood-steel%20connection%20loaded%20parallel%20to%20the%20grain.pdf http://umpir.ump.edu.my/id/eprint/34569/ https://doi.org/10.24425/ace.2022.140628 https://doi.org/10.24425/ace.2022.140628 |
_version_ |
1739828262789447680 |
score |
13.211869 |