Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia

The use of the electrical resistivity imaging (ERI) approach has expanded dramatically in engineering applications over the years due to the efficiency of the technique in terms of time, expense, and data coverage. The assessment was carried out using ERI to assess the landfill leachate's pollu...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad Syamsul Imran, Zaini, Muzamir, Hasan, Muhammad Farhan, Zolkepli
Format: Article
Language:English
Published: Elsevier 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/32844/1/SJR-ELS%20%282022%29%20Urban%20landfills%20investigation%20for%20leachate%20assessment%20using%20electrical%20%281%29.pdf
http://umpir.ump.edu.my/id/eprint/32844/
https://doi.org/10.1016/j.envc.2021.100415
https://doi.org/10.1016/j.envc.2021.100415
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.32844
record_format eprints
spelling my.ump.umpir.328442022-05-27T07:08:02Z http://umpir.ump.edu.my/id/eprint/32844/ Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia Muhammad Syamsul Imran, Zaini Muzamir, Hasan Muhammad Farhan, Zolkepli GE Environmental Sciences QE Geology TA Engineering (General). Civil engineering (General) The use of the electrical resistivity imaging (ERI) approach has expanded dramatically in engineering applications over the years due to the efficiency of the technique in terms of time, expense, and data coverage. The assessment was carried out using ERI to assess the landfill leachate's pollution level at Simpang Renggam, Johor, Malaysia. The ERI survey was carried out in the research region, utilizing the ABEM Terrameter LS 2 equipment using the Schlumberger electrode configuration. Besides, seven (7) parameters of leachate characterization such as Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD5), Suspended Solid (SS), Power of Hydrogen (pH), Ammonia Hydrogen (NH3-N), Turbidity and Biodegradability Ratio (BOD5/COD) were also performed to identify and evaluate the current leachate condition of the landfill. Furthermore, the study, which involves the measurement of the apparent resistivity of the subsurface materials were able to determine the existence of chemical pollutants in the soil at 1.5 m to 4.0 m depth, with special reference to the chemically apparent resistivity linked with the low resistivity anomalies of 1 – 10 Ωm. Based on the investigations conducted, the physiochemical and microbial analysis of the Simpang Renggam leachate site was found to be 1633 mg/L (Chemical Oxygen Demand), 137.41 mg/L (Biological Oxygen Demand), 359.8 mg/L (Suspended Solid), 7.61 (Power of Hydrogen), 385.29 (Ammonia Hydrogen), 117.65 (Turbidity) and 0.07 (Biodegradability Ratio) which shows that all of the parameter's value exceeded the value as stated in the local standard which is Environmental Quality Act (1974) except for the pH value which is within the range value as stated in the standard. The leachate from dumps was thought to arise due to system failures in accepting and managing trash, which was exacerbated by the recent high rains. In hindsight, the ERI result was practical for identifying leachate and, therefore, can benefit the authorities in immediate action to halt the extensive water disturbance at the research region. Elsevier 2021-11-30 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/32844/1/SJR-ELS%20%282022%29%20Urban%20landfills%20investigation%20for%20leachate%20assessment%20using%20electrical%20%281%29.pdf Muhammad Syamsul Imran, Zaini and Muzamir, Hasan and Muhammad Farhan, Zolkepli (2021) Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia. Environmental Challenges, 6 (100415). pp. 1-10. ISSN 2667-0100 https://doi.org/10.1016/j.envc.2021.100415 https://doi.org/10.1016/j.envc.2021.100415
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic GE Environmental Sciences
QE Geology
TA Engineering (General). Civil engineering (General)
spellingShingle GE Environmental Sciences
QE Geology
TA Engineering (General). Civil engineering (General)
Muhammad Syamsul Imran, Zaini
Muzamir, Hasan
Muhammad Farhan, Zolkepli
Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
description The use of the electrical resistivity imaging (ERI) approach has expanded dramatically in engineering applications over the years due to the efficiency of the technique in terms of time, expense, and data coverage. The assessment was carried out using ERI to assess the landfill leachate's pollution level at Simpang Renggam, Johor, Malaysia. The ERI survey was carried out in the research region, utilizing the ABEM Terrameter LS 2 equipment using the Schlumberger electrode configuration. Besides, seven (7) parameters of leachate characterization such as Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD5), Suspended Solid (SS), Power of Hydrogen (pH), Ammonia Hydrogen (NH3-N), Turbidity and Biodegradability Ratio (BOD5/COD) were also performed to identify and evaluate the current leachate condition of the landfill. Furthermore, the study, which involves the measurement of the apparent resistivity of the subsurface materials were able to determine the existence of chemical pollutants in the soil at 1.5 m to 4.0 m depth, with special reference to the chemically apparent resistivity linked with the low resistivity anomalies of 1 – 10 Ωm. Based on the investigations conducted, the physiochemical and microbial analysis of the Simpang Renggam leachate site was found to be 1633 mg/L (Chemical Oxygen Demand), 137.41 mg/L (Biological Oxygen Demand), 359.8 mg/L (Suspended Solid), 7.61 (Power of Hydrogen), 385.29 (Ammonia Hydrogen), 117.65 (Turbidity) and 0.07 (Biodegradability Ratio) which shows that all of the parameter's value exceeded the value as stated in the local standard which is Environmental Quality Act (1974) except for the pH value which is within the range value as stated in the standard. The leachate from dumps was thought to arise due to system failures in accepting and managing trash, which was exacerbated by the recent high rains. In hindsight, the ERI result was practical for identifying leachate and, therefore, can benefit the authorities in immediate action to halt the extensive water disturbance at the research region.
format Article
author Muhammad Syamsul Imran, Zaini
Muzamir, Hasan
Muhammad Farhan, Zolkepli
author_facet Muhammad Syamsul Imran, Zaini
Muzamir, Hasan
Muhammad Farhan, Zolkepli
author_sort Muhammad Syamsul Imran, Zaini
title Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
title_short Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
title_full Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
title_fullStr Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
title_full_unstemmed Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
title_sort urban landfills investigation for leachate assessment using electrical resistivity imaging in johor, malaysia
publisher Elsevier
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/32844/1/SJR-ELS%20%282022%29%20Urban%20landfills%20investigation%20for%20leachate%20assessment%20using%20electrical%20%281%29.pdf
http://umpir.ump.edu.my/id/eprint/32844/
https://doi.org/10.1016/j.envc.2021.100415
https://doi.org/10.1016/j.envc.2021.100415
_version_ 1734300289981218816
score 13.211869