Optimal allocation and sizing of multi DG units including different load model using evolutionary programming
This paper presents the optimal allocation and sizing of multi distributed generation (DG) units including different load models using evolutionary programming (EP) in solving power system optimization problem. This paper also studies on the effect of multi DG placement in different load model. To o...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2021
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/32010/1/Optimal%20allocation%20and%20sizing%20of%20multi%20DG%20units.pdf http://umpir.ump.edu.my/id/eprint/32010/ https://doi.org/10.1088/1742-6596/1878/1/012036 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.32010 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.320102022-02-11T08:16:58Z http://umpir.ump.edu.my/id/eprint/32010/ Optimal allocation and sizing of multi DG units including different load model using evolutionary programming M. F., Mohammed S. R., A. Rahim A., Azmi W. Z., Wan Zanudin M. H., Hussain N., Hashim Omar, Aliman TK Electrical engineering. Electronics Nuclear engineering This paper presents the optimal allocation and sizing of multi distributed generation (DG) units including different load models using evolutionary programming (EP) in solving power system optimization problem. This paper also studies on the effect of multi DG placement in different load model. To optimize the power distribution system, multi DG units were used to reduce losses power distribution system. By using EP, the optimal allocation and sizing of multi-DG was determined in order to obtain maximum benefits from its installation. The propose technique was tested into IEEE 69-bus distribution system. The result shows the placement of DG can reduce power loss 89% to 98%. The placement of multi-DG unit has better performance compare to single DG. IOP Publishing 2021-06-11 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/32010/1/Optimal%20allocation%20and%20sizing%20of%20multi%20DG%20units.pdf M. F., Mohammed and S. R., A. Rahim and A., Azmi and W. Z., Wan Zanudin and M. H., Hussain and N., Hashim and Omar, Aliman (2021) Optimal allocation and sizing of multi DG units including different load model using evolutionary programming. In: Journal of Physics: Conference Series; 2nd International Conference on Emerging Electrical Energy, Electronics and Computing Technologies 2020, ICE4CT 2020, 21 - 22 December 2020 , Melaka. pp. 1-12., 1878 (1). ISSN 1742-6588 (print); 1742-6596 (online) https://doi.org/10.1088/1742-6596/1878/1/012036 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering M. F., Mohammed S. R., A. Rahim A., Azmi W. Z., Wan Zanudin M. H., Hussain N., Hashim Omar, Aliman Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
description |
This paper presents the optimal allocation and sizing of multi distributed generation (DG) units including different load models using evolutionary programming (EP) in solving power system optimization problem. This paper also studies on the effect of multi DG placement in different load model. To optimize the power distribution system, multi DG units were used to reduce losses power distribution system. By using EP, the optimal allocation and sizing of multi-DG was determined in order to obtain maximum benefits from its installation. The propose technique was tested into IEEE 69-bus distribution system. The result shows the placement of DG can reduce power loss 89% to 98%. The placement of multi-DG unit has better performance compare to single DG. |
format |
Conference or Workshop Item |
author |
M. F., Mohammed S. R., A. Rahim A., Azmi W. Z., Wan Zanudin M. H., Hussain N., Hashim Omar, Aliman |
author_facet |
M. F., Mohammed S. R., A. Rahim A., Azmi W. Z., Wan Zanudin M. H., Hussain N., Hashim Omar, Aliman |
author_sort |
M. F., Mohammed |
title |
Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
title_short |
Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
title_full |
Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
title_fullStr |
Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
title_full_unstemmed |
Optimal allocation and sizing of multi DG units including different load model using evolutionary programming |
title_sort |
optimal allocation and sizing of multi dg units including different load model using evolutionary programming |
publisher |
IOP Publishing |
publishDate |
2021 |
url |
http://umpir.ump.edu.my/id/eprint/32010/1/Optimal%20allocation%20and%20sizing%20of%20multi%20DG%20units.pdf http://umpir.ump.edu.my/id/eprint/32010/ https://doi.org/10.1088/1742-6596/1878/1/012036 |
_version_ |
1724608133335089152 |
score |
13.159267 |