Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach
Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In t...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Malaysian Society for Computed Tomography and Imaging (MyCT)
2021
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/31770/1/published_2021_Does%20Parallel%20Projection%20is%20Suitable%20in%20Electrical%20Capacitance%20Tomography%20%E2%80%93A%20Comparison%20with%20Common%20Approach.pdf http://umpir.ump.edu.my/id/eprint/31770/ http://www.tssa.my/index.php/jtssa/article/view/154 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.31770 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.317702021-08-20T08:40:53Z http://umpir.ump.edu.my/id/eprint/31770/ Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach Muhammad Faris Aiman, Hisham Yasmin, Abdul Wahab Zainah, Md. Zain Nurhafizah, Abu Talip Rohana, Abdul Karim Nor Farizan, Zakaria Nurul Wahidah, Arshad T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In this paper, an ECT system with a comparison between common approach and a parallel approach is presented. Simulation in 2 dimensions with 16-electrode is carried out to observe a potential projection. The COMSOL Multiphysics software is used to investigate the state and response of the electric field with this approach by exporting data with 128x128 pixels. Air bubbles as a phantom in the oil medium have been tested and analyzed. Linear Back-Projection Algorithm (LBP) is implemented using MATLAB software to obtain a tomogram. A Multi Scale Structural Similarity, MSSIM was applied to compare both approaches. Consequently, the resolution and quality of the pictures in the pipes can be distinguished. However, a further investigation is needed to improve the parallel approach for ECT system. Malaysian Society for Computed Tomography and Imaging (MyCT) 2021-03 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/31770/1/published_2021_Does%20Parallel%20Projection%20is%20Suitable%20in%20Electrical%20Capacitance%20Tomography%20%E2%80%93A%20Comparison%20with%20Common%20Approach.pdf Muhammad Faris Aiman, Hisham and Yasmin, Abdul Wahab and Zainah, Md. Zain and Nurhafizah, Abu Talip and Rohana, Abdul Karim and Nor Farizan, Zakaria and Nurul Wahidah, Arshad (2021) Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach. Journal of Tomography System & Sensors Application, 4 (1). pp. 85-92. ISSN 2636-9133 http://www.tssa.my/index.php/jtssa/article/view/154 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
T Technology (General) TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Muhammad Faris Aiman, Hisham Yasmin, Abdul Wahab Zainah, Md. Zain Nurhafizah, Abu Talip Rohana, Abdul Karim Nor Farizan, Zakaria Nurul Wahidah, Arshad Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
description |
Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In this paper, an ECT system with a comparison between common approach and a parallel approach is presented. Simulation in 2 dimensions with 16-electrode is carried out to observe a potential projection. The COMSOL Multiphysics software is used to investigate the state and response of the electric field with this approach by exporting data with 128x128 pixels. Air bubbles as a phantom in the oil medium have been tested and analyzed. Linear Back-Projection Algorithm (LBP) is implemented using MATLAB software to obtain a tomogram. A Multi Scale Structural Similarity, MSSIM was applied to compare both approaches. Consequently, the resolution and quality of the pictures in the pipes can be distinguished. However, a further investigation is needed to improve the parallel approach for ECT system. |
format |
Article |
author |
Muhammad Faris Aiman, Hisham Yasmin, Abdul Wahab Zainah, Md. Zain Nurhafizah, Abu Talip Rohana, Abdul Karim Nor Farizan, Zakaria Nurul Wahidah, Arshad |
author_facet |
Muhammad Faris Aiman, Hisham Yasmin, Abdul Wahab Zainah, Md. Zain Nurhafizah, Abu Talip Rohana, Abdul Karim Nor Farizan, Zakaria Nurul Wahidah, Arshad |
author_sort |
Muhammad Faris Aiman, Hisham |
title |
Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
title_short |
Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
title_full |
Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
title_fullStr |
Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
title_full_unstemmed |
Does Parallel Projection is Suitable in Electrical Capacitance Tomography? –A Comparison with Common Approach |
title_sort |
does parallel projection is suitable in electrical capacitance tomography? –a comparison with common approach |
publisher |
Malaysian Society for Computed Tomography and Imaging (MyCT) |
publishDate |
2021 |
url |
http://umpir.ump.edu.my/id/eprint/31770/1/published_2021_Does%20Parallel%20Projection%20is%20Suitable%20in%20Electrical%20Capacitance%20Tomography%20%E2%80%93A%20Comparison%20with%20Common%20Approach.pdf http://umpir.ump.edu.my/id/eprint/31770/ http://www.tssa.my/index.php/jtssa/article/view/154 |
_version_ |
1709667684094836736 |
score |
13.160551 |