Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide

Petroleum refinery wastewater typically has high concentration of sulfide which is known as the most hazardous pollutants. It is released to the environment either as dissolved sulfide (S2- and HS-) in effluents or as H2S in waste gases. The objective in this study is to determine the effectiveness...

Full description

Saved in:
Bibliographic Details
Main Authors: M. C., Mamat, Ahmad Bazli, Bustary, Abdul Aziz, Mohd Azoddein
Format: Article
Language:English
Published: IOP Publishing Ltd 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/31526/1/Mamat_2020_IOP_Conf._Ser.__Mater._Sci._Eng._736_022103.pdf
http://umpir.ump.edu.my/id/eprint/31526/
https://ioppublishing.org/publications/conference-series/
http://doi:10.1088/1757-899X/736/2/022103
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.31526
record_format eprints
spelling my.ump.umpir.315262021-06-14T04:50:44Z http://umpir.ump.edu.my/id/eprint/31526/ Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide M. C., Mamat Ahmad Bazli, Bustary Abdul Aziz, Mohd Azoddein TD Environmental technology. Sanitary engineering TP Chemical technology Petroleum refinery wastewater typically has high concentration of sulfide which is known as the most hazardous pollutants. It is released to the environment either as dissolved sulfide (S2- and HS-) in effluents or as H2S in waste gases. The objective in this study is to determine the effectiveness of hydrogen peroxide (H2O2) in sulfide removal. The best sulfide concentration, dosage and reaction time were determined. The removal of sulfide from petroleum refinery wastewater via oxidation method by using hydrogen peroxide (H2O2) is presented in this study. The treated wastewater was analyzed by spectrophotometer. Result shows that the best concentration of sulfide simulated wastewater (300 mg/L), H2O2 dosage (1.5 ml) and reaction time (30 min) able to reduce 97.67%, 98.22% and 98.89% of sulfide concentration from simulated wastewater. Thus, sulfide removal from the actual petroleum refinery wastewater which is spent caustic by using H2O2 was able to reduce 99.83% (0.5 mg/L) sulfide concentration. Besides that, Chemical Oxygen Demand (COD) concentration was reduced to 98.29% (70 mg/L) and pH 8.41 after treatment. Thus, it is concluded that oxidation method by using H2O2 is effective in sulfide removal as well as COD, and pH from spent caustic. It does meet requirement from Department of Environment (DOE) for sulfide, COD and pH which are 0.5 mg/L, 100 mg/L and 5.5 – 9.0, respectively. The information obtained from this study is useful for scale up purpose in the petroleum refining industry that choose H2O2 via oxidation method to remove sulfide from spent caustic wastewater. IOP Publishing Ltd 2020 Article PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/31526/1/Mamat_2020_IOP_Conf._Ser.__Mater._Sci._Eng._736_022103.pdf M. C., Mamat and Ahmad Bazli, Bustary and Abdul Aziz, Mohd Azoddein (2020) Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide. IOP Conference Series: Materials Science and Engineering, 736 (022103). pp. 1-11. ISSN 17578981 https://ioppublishing.org/publications/conference-series/ http://doi:10.1088/1757-899X/736/2/022103
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TD Environmental technology. Sanitary engineering
TP Chemical technology
spellingShingle TD Environmental technology. Sanitary engineering
TP Chemical technology
M. C., Mamat
Ahmad Bazli, Bustary
Abdul Aziz, Mohd Azoddein
Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
description Petroleum refinery wastewater typically has high concentration of sulfide which is known as the most hazardous pollutants. It is released to the environment either as dissolved sulfide (S2- and HS-) in effluents or as H2S in waste gases. The objective in this study is to determine the effectiveness of hydrogen peroxide (H2O2) in sulfide removal. The best sulfide concentration, dosage and reaction time were determined. The removal of sulfide from petroleum refinery wastewater via oxidation method by using hydrogen peroxide (H2O2) is presented in this study. The treated wastewater was analyzed by spectrophotometer. Result shows that the best concentration of sulfide simulated wastewater (300 mg/L), H2O2 dosage (1.5 ml) and reaction time (30 min) able to reduce 97.67%, 98.22% and 98.89% of sulfide concentration from simulated wastewater. Thus, sulfide removal from the actual petroleum refinery wastewater which is spent caustic by using H2O2 was able to reduce 99.83% (0.5 mg/L) sulfide concentration. Besides that, Chemical Oxygen Demand (COD) concentration was reduced to 98.29% (70 mg/L) and pH 8.41 after treatment. Thus, it is concluded that oxidation method by using H2O2 is effective in sulfide removal as well as COD, and pH from spent caustic. It does meet requirement from Department of Environment (DOE) for sulfide, COD and pH which are 0.5 mg/L, 100 mg/L and 5.5 – 9.0, respectively. The information obtained from this study is useful for scale up purpose in the petroleum refining industry that choose H2O2 via oxidation method to remove sulfide from spent caustic wastewater.
format Article
author M. C., Mamat
Ahmad Bazli, Bustary
Abdul Aziz, Mohd Azoddein
author_facet M. C., Mamat
Ahmad Bazli, Bustary
Abdul Aziz, Mohd Azoddein
author_sort M. C., Mamat
title Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
title_short Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
title_full Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
title_fullStr Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
title_full_unstemmed Oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
title_sort oxidation of sulfide removal from petroleum refinery wastewater by using hydrogen peroxide
publisher IOP Publishing Ltd
publishDate 2020
url http://umpir.ump.edu.my/id/eprint/31526/1/Mamat_2020_IOP_Conf._Ser.__Mater._Sci._Eng._736_022103.pdf
http://umpir.ump.edu.my/id/eprint/31526/
https://ioppublishing.org/publications/conference-series/
http://doi:10.1088/1757-899X/736/2/022103
_version_ 1703960799503974400
score 13.154949