Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage

This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a pollutedenvironment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self tu...

Full description

Saved in:
Bibliographic Details
Main Authors: Omran, Mohamed Asghaiyer, Izzeldin, I. Mohd, Abu Zaharin, Ahmad, Salem, Mohamed, Almelian, Mohamad Milood, Awang, Jusoh, Sutikno, Tole
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science (IAES) 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/30037/1/Comparisons%20of%20PI%20and%20ANN%20controllers.pdf
http://umpir.ump.edu.my/id/eprint/30037/
http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.30037
record_format eprints
spelling my.ump.umpir.300372020-11-24T05:03:50Z http://umpir.ump.edu.my/id/eprint/30037/ Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage Omran, Mohamed Asghaiyer Izzeldin, I. Mohd Abu Zaharin, Ahmad Salem, Mohamed Almelian, Mohamad Milood Awang, Jusoh Sutikno, Tole TK Electrical engineering. Electronics Nuclear engineering This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a pollutedenvironment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self tuning filter (STF). In order to adjust the dc voltage as a reference value, PI and ANN controllers have been utilized. Moreover, the system has been implemented and simulated in a MATLAB-SIMULINK platform, and selected results are presented. Therefore, the results verified the good dynamic performance, transient stability and strong robustness of the ANN controller. Furthermore, the shunt HAPF with ANN controller has been found to be in agreement with the IEEE 519-1992 standard recommendations on harmonic levels. Institute of Advanced Engineering and Science (IAES) 2019 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/30037/1/Comparisons%20of%20PI%20and%20ANN%20controllers.pdf Omran, Mohamed Asghaiyer and Izzeldin, I. Mohd and Abu Zaharin, Ahmad and Salem, Mohamed and Almelian, Mohamad Milood and Awang, Jusoh and Sutikno, Tole (2019) Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage. International Journal of Power Electronics and Drive System (IJPEDS), 10 (3). pp. 1339-1346. ISSN 2088-8694 (print); 2088-8694 (online) http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346 http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Salem, Mohamed
Almelian, Mohamad Milood
Awang, Jusoh
Sutikno, Tole
Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
description This paper proposes a shunt hybrid power filter (HPF) for harmonic currents and reactive power compensation under a distorted voltage and in a pollutedenvironment. For this purpose, the reference current of the shunt HPF is computed based on the instantaneous reactive power (p-q) theory with self tuning filter (STF). In order to adjust the dc voltage as a reference value, PI and ANN controllers have been utilized. Moreover, the system has been implemented and simulated in a MATLAB-SIMULINK platform, and selected results are presented. Therefore, the results verified the good dynamic performance, transient stability and strong robustness of the ANN controller. Furthermore, the shunt HAPF with ANN controller has been found to be in agreement with the IEEE 519-1992 standard recommendations on harmonic levels.
format Article
author Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Salem, Mohamed
Almelian, Mohamad Milood
Awang, Jusoh
Sutikno, Tole
author_facet Omran, Mohamed Asghaiyer
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Salem, Mohamed
Almelian, Mohamad Milood
Awang, Jusoh
Sutikno, Tole
author_sort Omran, Mohamed Asghaiyer
title Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
title_short Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
title_full Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
title_fullStr Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
title_full_unstemmed Comparisons of PI and ANN controllers for shunt HPF based on STF-PQ Algorithm under distorted grid voltage
title_sort comparisons of pi and ann controllers for shunt hpf based on stf-pq algorithm under distorted grid voltage
publisher Institute of Advanced Engineering and Science (IAES)
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/30037/1/Comparisons%20of%20PI%20and%20ANN%20controllers.pdf
http://umpir.ump.edu.my/id/eprint/30037/
http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
http://doi.org/10.11591/ijpeds.v10.i3.pp1339-1346
_version_ 1684653583686959104
score 13.159267