A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2020
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf http://umpir.ump.edu.my/id/eprint/29353/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.29353 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.293532022-01-21T08:19:59Z http://umpir.ump.edu.my/id/eprint/29353/ A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor G. M., Salim Mohd Anwar, Zawawi TK Electrical engineering. Electronics Nuclear engineering Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive use is not preferably suggested by physicians due to the high cost and other associated side-effect related to exposure to radiation. Due to these factors, an alternative device based on optical fibre sensor is proposed in this study. The proposed knee monitoring sensor is based on the use on step index type plastic optical fibre and linear array photodiode sensor. Based on the mathematical estimation and initial sensor measurement, this sensor is able to perform full range of motion between 0 to 155 degrees. The accuracy and resolution of this sensor is 1.0 degree and 0.5 degree, respectively. The aim of this study is to determine the current performance of the device before further improvement could be proposed. IOP Publishing 2020 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf G. M., Salim and Mohd Anwar, Zawawi (2020) A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor. In: Journal of Physics: Conference Series, The 2nd Joint International Conference on Emerging Computing Technology and Sports (JICETS 2019), 25-27 November 2019 , Bandung, Indonesia. pp. 1-8., 1529 (042069). ISSN 1742-6588 (print); 1742-6596 (online) |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering G. M., Salim Mohd Anwar, Zawawi A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
description |
Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive use is not preferably suggested by physicians due to the high cost and other associated side-effect related to exposure to radiation. Due to these factors, an alternative device based on optical fibre sensor is proposed in this study. The proposed knee monitoring sensor is based on the use on step index type plastic optical fibre and linear array photodiode sensor. Based on the mathematical estimation and initial sensor measurement, this sensor is able to perform full range of motion between 0 to 155 degrees. The accuracy and resolution of this sensor is 1.0 degree and 0.5 degree, respectively. The aim of this study is to determine the current performance of the device before further improvement could be proposed. |
format |
Conference or Workshop Item |
author |
G. M., Salim Mohd Anwar, Zawawi |
author_facet |
G. M., Salim Mohd Anwar, Zawawi |
author_sort |
G. M., Salim |
title |
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
title_short |
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
title_full |
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
title_fullStr |
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
title_full_unstemmed |
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
title_sort |
novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor |
publisher |
IOP Publishing |
publishDate |
2020 |
url |
http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf http://umpir.ump.edu.my/id/eprint/29353/ |
_version_ |
1724073480082685952 |
score |
13.209306 |