A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor

Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive...

Full description

Saved in:
Bibliographic Details
Main Authors: G. M., Salim, Mohd Anwar, Zawawi
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf
http://umpir.ump.edu.my/id/eprint/29353/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.29353
record_format eprints
spelling my.ump.umpir.293532022-01-21T08:19:59Z http://umpir.ump.edu.my/id/eprint/29353/ A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor G. M., Salim Mohd Anwar, Zawawi TK Electrical engineering. Electronics Nuclear engineering Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive use is not preferably suggested by physicians due to the high cost and other associated side-effect related to exposure to radiation. Due to these factors, an alternative device based on optical fibre sensor is proposed in this study. The proposed knee monitoring sensor is based on the use on step index type plastic optical fibre and linear array photodiode sensor. Based on the mathematical estimation and initial sensor measurement, this sensor is able to perform full range of motion between 0 to 155 degrees. The accuracy and resolution of this sensor is 1.0 degree and 0.5 degree, respectively. The aim of this study is to determine the current performance of the device before further improvement could be proposed. IOP Publishing 2020 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf G. M., Salim and Mohd Anwar, Zawawi (2020) A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor. In: Journal of Physics: Conference Series, The 2nd Joint International Conference on Emerging Computing Technology and Sports (JICETS 2019), 25-27 November 2019 , Bandung, Indonesia. pp. 1-8., 1529 (042069). ISSN 1742-6588 (print); 1742-6596 (online)
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
G. M., Salim
Mohd Anwar, Zawawi
A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
description Knee monitoring is one of the common injuries suffered by people who are active in extreme sports. Traditional ways to identify these problems are based on background study of the patient, physical examination, and sometimes with the use of x-rays and MRIs. The use of x-rays and MRIs for repetitive use is not preferably suggested by physicians due to the high cost and other associated side-effect related to exposure to radiation. Due to these factors, an alternative device based on optical fibre sensor is proposed in this study. The proposed knee monitoring sensor is based on the use on step index type plastic optical fibre and linear array photodiode sensor. Based on the mathematical estimation and initial sensor measurement, this sensor is able to perform full range of motion between 0 to 155 degrees. The accuracy and resolution of this sensor is 1.0 degree and 0.5 degree, respectively. The aim of this study is to determine the current performance of the device before further improvement could be proposed.
format Conference or Workshop Item
author G. M., Salim
Mohd Anwar, Zawawi
author_facet G. M., Salim
Mohd Anwar, Zawawi
author_sort G. M., Salim
title A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
title_short A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
title_full A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
title_fullStr A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
title_full_unstemmed A novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
title_sort novel implementation of knee joint monitoring device using step index optical fibre and linear array photodiode sensor
publisher IOP Publishing
publishDate 2020
url http://umpir.ump.edu.my/id/eprint/29353/1/23.%20A%20novel%20implementation%20of%20knee%20joint%20monitoring%20device%20using%20step%20index.pdf
http://umpir.ump.edu.my/id/eprint/29353/
_version_ 1724073480082685952