The effect of perforations on built-up open section cold-formed steel beam

This paper presents the study of the effect on built-up open section when receiving load in term of flexural behavior (failure mode) and the ultimate load with the present of web perforations. In steel production, there are two types of structural members which are hotrolled steel and the other one...

Full description

Saved in:
Bibliographic Details
Main Author: Siti Sharina, Baharom
Format: Undergraduates Project Papers
Language:English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29061/1/The%20effect%20of%20perforations%20on%20built-up%20open%20section%20cold-formed%20steel.pdf
http://umpir.ump.edu.my/id/eprint/29061/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.29061
record_format eprints
spelling my.ump.umpir.290612020-08-17T03:53:17Z http://umpir.ump.edu.my/id/eprint/29061/ The effect of perforations on built-up open section cold-formed steel beam Siti Sharina, Baharom TA Engineering (General). Civil engineering (General) This paper presents the study of the effect on built-up open section when receiving load in term of flexural behavior (failure mode) and the ultimate load with the present of web perforations. In steel production, there are two types of structural members which are hotrolled steel and the other one is cold-formed steel. In detail, cold-formed steel is pressed at significantly cooler temperatures and often even room temperature. Hot-rolled steel is heated above the metal recrystallization temperature (around 1700° F or higher) to make it easier to bend the metal into specific shape. This experiment is involving the beam test on several specimens focuses on built-up open section steel with various position of webopening on the beam. Each specimen have 1600 mm length and different position of webperforations. The shape of openings used are circle and the size are keep constant that is 20 mm diameter to ensure the consistency in the result making. The ultimate load strength of the cold-formed steel section and failure modes differs depend on the position of the openings and the number of the opening, where the conclusions are make on the basis of the comparisons between the positions of openings. The value of displacement was measured by using the transducer which placed at the middle point below the beam. The load – displacement graph was plotted after the result is obtained. 2018-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29061/1/The%20effect%20of%20perforations%20on%20built-up%20open%20section%20cold-formed%20steel.pdf Siti Sharina, Baharom (2018) The effect of perforations on built-up open section cold-formed steel beam. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Siti Sharina, Baharom
The effect of perforations on built-up open section cold-formed steel beam
description This paper presents the study of the effect on built-up open section when receiving load in term of flexural behavior (failure mode) and the ultimate load with the present of web perforations. In steel production, there are two types of structural members which are hotrolled steel and the other one is cold-formed steel. In detail, cold-formed steel is pressed at significantly cooler temperatures and often even room temperature. Hot-rolled steel is heated above the metal recrystallization temperature (around 1700° F or higher) to make it easier to bend the metal into specific shape. This experiment is involving the beam test on several specimens focuses on built-up open section steel with various position of webopening on the beam. Each specimen have 1600 mm length and different position of webperforations. The shape of openings used are circle and the size are keep constant that is 20 mm diameter to ensure the consistency in the result making. The ultimate load strength of the cold-formed steel section and failure modes differs depend on the position of the openings and the number of the opening, where the conclusions are make on the basis of the comparisons between the positions of openings. The value of displacement was measured by using the transducer which placed at the middle point below the beam. The load – displacement graph was plotted after the result is obtained.
format Undergraduates Project Papers
author Siti Sharina, Baharom
author_facet Siti Sharina, Baharom
author_sort Siti Sharina, Baharom
title The effect of perforations on built-up open section cold-formed steel beam
title_short The effect of perforations on built-up open section cold-formed steel beam
title_full The effect of perforations on built-up open section cold-formed steel beam
title_fullStr The effect of perforations on built-up open section cold-formed steel beam
title_full_unstemmed The effect of perforations on built-up open section cold-formed steel beam
title_sort effect of perforations on built-up open section cold-formed steel beam
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/29061/1/The%20effect%20of%20perforations%20on%20built-up%20open%20section%20cold-formed%20steel.pdf
http://umpir.ump.edu.my/id/eprint/29061/
_version_ 1675327482056671232
score 13.18916