Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector

The aim of this paper is to discuss the non-dimensional numbers of fluid flowing through inside the tubes of flat plate solar collectors. Empirically, to abate the cost and energy consumption or to boost up the performance and efficiency of solar collectors; computational simulation plays a vital ro...

Full description

Saved in:
Bibliographic Details
Main Authors: Farhana, K., K., Kadirgama, M. M., Noor
Format: Conference or Workshop Item
Language:English
Published: Springer, Singapore 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28965/1/Analysis%20of%20Non-dimensional%20Numbers%20of%20Fluid%20Flowing1.pdf
http://umpir.ump.edu.my/id/eprint/28965/
https://doi.org/10.1007/978-981-15-7309-5_12
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.28965
record_format eprints
spelling my.ump.umpir.289652020-08-13T01:23:21Z http://umpir.ump.edu.my/id/eprint/28965/ Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector Farhana, K. K., Kadirgama M. M., Noor TJ Mechanical engineering and machinery The aim of this paper is to discuss the non-dimensional numbers of fluid flowing through inside the tubes of flat plate solar collectors. Empirically, to abate the cost and energy consumption or to boost up the performance and efficiency of solar collectors; computational simulation plays a vital role. In this study, CFD numerical simulation of aqueous ethylene glycol (60% water + 40%) ethylene glycol fluid flow has been done with ANSYS 15.0. Non-dimensional numbers such as surface Nusselt number, Skin friction coefficient and Prandtl number of fluids have been observed based on empirical and experimental properties. The geometry of design has been prepared using Solidworks software in accordance with the actual experimental model. The analysis revealed that the Nusselt number showed effective convection behavior, the skin friction coefficient was positive while the Prandtl number was large for both properties of aqueous ethylene glycol. Springer, Singapore 2021 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/28965/1/Analysis%20of%20Non-dimensional%20Numbers%20of%20Fluid%20Flowing1.pdf Farhana, K. and K., Kadirgama and M. M., Noor (2021) Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector. In: Advances in Mechatronics, Manufacturing, and Mechanical Engineering: Selected articles from MUCET 2019, 19-22 November 2019 , Bukit Gambang Resort City, Pahang, Malaysia. pp. 121-131.. ISBN 978-981-15-7309-5 https://doi.org/10.1007/978-981-15-7309-5_12
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Farhana, K.
K., Kadirgama
M. M., Noor
Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
description The aim of this paper is to discuss the non-dimensional numbers of fluid flowing through inside the tubes of flat plate solar collectors. Empirically, to abate the cost and energy consumption or to boost up the performance and efficiency of solar collectors; computational simulation plays a vital role. In this study, CFD numerical simulation of aqueous ethylene glycol (60% water + 40%) ethylene glycol fluid flow has been done with ANSYS 15.0. Non-dimensional numbers such as surface Nusselt number, Skin friction coefficient and Prandtl number of fluids have been observed based on empirical and experimental properties. The geometry of design has been prepared using Solidworks software in accordance with the actual experimental model. The analysis revealed that the Nusselt number showed effective convection behavior, the skin friction coefficient was positive while the Prandtl number was large for both properties of aqueous ethylene glycol.
format Conference or Workshop Item
author Farhana, K.
K., Kadirgama
M. M., Noor
author_facet Farhana, K.
K., Kadirgama
M. M., Noor
author_sort Farhana, K.
title Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
title_short Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
title_full Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
title_fullStr Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
title_full_unstemmed Analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
title_sort analysis of non-dimensional numbers of fluid flowing inside tubes of flat plate solar collector
publisher Springer, Singapore
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/28965/1/Analysis%20of%20Non-dimensional%20Numbers%20of%20Fluid%20Flowing1.pdf
http://umpir.ump.edu.my/id/eprint/28965/
https://doi.org/10.1007/978-981-15-7309-5_12
_version_ 1675327474911674368
score 13.160551