Experimental study on the performance of vortex tube cooling device on a cooling jacket

A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well co...

Full description

Saved in:
Bibliographic Details
Main Authors: Lim, Sheh Hong, Muhammad Fadhli, Suhaimi, Mohd Hazwan, Yusof
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf
http://umpir.ump.edu.my/id/eprint/28478/
https://doi.org/10.1088/1755-1315/581/1/012018
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.28478
record_format eprints
spelling my.ump.umpir.284782021-02-03T01:10:04Z http://umpir.ump.edu.my/id/eprint/28478/ Experimental study on the performance of vortex tube cooling device on a cooling jacket Lim, Sheh Hong Muhammad Fadhli, Suhaimi Mohd Hazwan, Yusof TJ Mechanical engineering and machinery A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well cooling device, there are fewer or no research works that were conducted on the application of vortex tube. So, the application of vortex tube as a cooling device on a cooling jacket is less explored. Hence, the performance of this application on experimental research is unclear. Therefore, the objectives for this research are to determine the performance of vortex tube as a cooling device on a cooling jacket at different cold mass flow rate and also to determine the performance of vortex tube as a cooling device on a cooling jacket at different inlet pressure. The performance of vortex tube on the cooling jacket is experimented with different cold mass flow rate ranging from 30L/min to 90L/min and different inlet pressure ranging from 200kPa to 500kPa. Both parameters were with several condition, which are conducted at indoor condition, inside an air-ventilated room and outdoor condition, under the sunlight. At the end of the experiment, 90L/min and 500kPa were the optimum value for the performance of vortex tube. It can be concluded that the higher the inlet pressure supplied to the vortex tube, the lower the air temperature produced, and the higher the cold mass flow rate, enables lower cold air generated to the cooling jacket. IOP Publishing 2020 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf Lim, Sheh Hong and Muhammad Fadhli, Suhaimi and Mohd Hazwan, Yusof (2020) Experimental study on the performance of vortex tube cooling device on a cooling jacket. In: IOP Conference Series: Earth and Environmental Science, 10th International Conference on Future Environment and Energy, 7-9 January 2020 , Kyoto, Japan. pp. 1-8., 581 (012018). ISSN 1755-1315 https://doi.org/10.1088/1755-1315/581/1/012018
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Lim, Sheh Hong
Muhammad Fadhli, Suhaimi
Mohd Hazwan, Yusof
Experimental study on the performance of vortex tube cooling device on a cooling jacket
description A vortex tube is an intriguing simple device which is capable of generating cold and hot streams from a single compressed fluid supply at room temperature. The vortex tube does not require any refrigerants or chemicals to operate which makes it an environmentally friendly device. Still, as a well cooling device, there are fewer or no research works that were conducted on the application of vortex tube. So, the application of vortex tube as a cooling device on a cooling jacket is less explored. Hence, the performance of this application on experimental research is unclear. Therefore, the objectives for this research are to determine the performance of vortex tube as a cooling device on a cooling jacket at different cold mass flow rate and also to determine the performance of vortex tube as a cooling device on a cooling jacket at different inlet pressure. The performance of vortex tube on the cooling jacket is experimented with different cold mass flow rate ranging from 30L/min to 90L/min and different inlet pressure ranging from 200kPa to 500kPa. Both parameters were with several condition, which are conducted at indoor condition, inside an air-ventilated room and outdoor condition, under the sunlight. At the end of the experiment, 90L/min and 500kPa were the optimum value for the performance of vortex tube. It can be concluded that the higher the inlet pressure supplied to the vortex tube, the lower the air temperature produced, and the higher the cold mass flow rate, enables lower cold air generated to the cooling jacket.
format Conference or Workshop Item
author Lim, Sheh Hong
Muhammad Fadhli, Suhaimi
Mohd Hazwan, Yusof
author_facet Lim, Sheh Hong
Muhammad Fadhli, Suhaimi
Mohd Hazwan, Yusof
author_sort Lim, Sheh Hong
title Experimental study on the performance of vortex tube cooling device on a cooling jacket
title_short Experimental study on the performance of vortex tube cooling device on a cooling jacket
title_full Experimental study on the performance of vortex tube cooling device on a cooling jacket
title_fullStr Experimental study on the performance of vortex tube cooling device on a cooling jacket
title_full_unstemmed Experimental study on the performance of vortex tube cooling device on a cooling jacket
title_sort experimental study on the performance of vortex tube cooling device on a cooling jacket
publisher IOP Publishing
publishDate 2020
url http://umpir.ump.edu.my/id/eprint/28478/13/Experimental%20study%20on%20the%20performance.pdf
http://umpir.ump.edu.my/id/eprint/28478/
https://doi.org/10.1088/1755-1315/581/1/012018
_version_ 1691733253350752256
score 13.160551