The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement

Nowadays construction industry focus in using green material which one of it is processed spent bleaching earth (PSBE) as pozzolan material which offer more pozzolanic reaction. Other than that, application of foamed concrete in construction getting wider from time to time as it able to have high se...

Full description

Saved in:
Bibliographic Details
Main Author: Afidatul Husna, Mohamad Syariff
Format: Undergraduates Project Papers
Language:English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27627/1/The%20effect%20of%20various%20position%20of%20cilcular%20hollow%20section%20on%20the%20strength%20of%20foamed.pdf
http://umpir.ump.edu.my/id/eprint/27627/
https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=90907
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.27627
record_format eprints
spelling my.ump.umpir.276272020-01-30T07:40:52Z http://umpir.ump.edu.my/id/eprint/27627/ The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement Afidatul Husna, Mohamad Syariff TA Engineering (General). Civil engineering (General) Nowadays construction industry focus in using green material which one of it is processed spent bleaching earth (PSBE) as pozzolan material which offer more pozzolanic reaction. Other than that, application of foamed concrete in construction getting wider from time to time as it able to have high self-compacting and self-flowing. The focus of this research is to study the effect of different location of circular hollow section on the flexural strength of foamed concrete beam containing processed spent bleaching earth as partial replacement of cement. The objectives of this research is to determine the maximum load of the flexural beam, the deflection of flexural beams and the mode of failure of the flexural beam by using four point bending test. By using 30% PSBE as partial replacement of cement, three beam sized 150mm x 200mm x 1500mm casted with 50mm circular hollow section were placed at different height and one controlbeam with the same size. Four point bending test were carried out to obtain the ultimate load and Linear Variable Displacement Transducer (LVDT) were used to measure the deflection. The crack pattern was observed and analyzed. The experimental result shows that Beam 2 produced greater maximum load with 3.320kN, flexural strength with 0.664 N/mm2 and deflection with 0.330mm. The loss percentage of flexural strength increased as the depth of hollow section increased which are 28%, 40.79% and 49.13% for Beam 2, Beam 3 and Beam 4 respectively when compared to Beam 1. The decrement of deflection compared to Beam 1 are 5.71%, 11.43% and 34.0% for Beam 2, Beam 3 and Beam 4 respectively. First crack on the beam was reflected as the ultimate crack since the beam were unreinforced. Hence, the flexural strength and deflection depend on the second moment of inertia which then second moment of inertia depends on the neutral axis. In short, the beam with hollow section at the neutral axis is the suitable beam for future planning of construction due to higher ultimate load and deflection.by adding the reinforcement in any beam application, will be better because the ultimate load and deflection value will be bigger. 2018-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27627/1/The%20effect%20of%20various%20position%20of%20cilcular%20hollow%20section%20on%20the%20strength%20of%20foamed.pdf Afidatul Husna, Mohamad Syariff (2018) The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=90907
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Afidatul Husna, Mohamad Syariff
The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
description Nowadays construction industry focus in using green material which one of it is processed spent bleaching earth (PSBE) as pozzolan material which offer more pozzolanic reaction. Other than that, application of foamed concrete in construction getting wider from time to time as it able to have high self-compacting and self-flowing. The focus of this research is to study the effect of different location of circular hollow section on the flexural strength of foamed concrete beam containing processed spent bleaching earth as partial replacement of cement. The objectives of this research is to determine the maximum load of the flexural beam, the deflection of flexural beams and the mode of failure of the flexural beam by using four point bending test. By using 30% PSBE as partial replacement of cement, three beam sized 150mm x 200mm x 1500mm casted with 50mm circular hollow section were placed at different height and one controlbeam with the same size. Four point bending test were carried out to obtain the ultimate load and Linear Variable Displacement Transducer (LVDT) were used to measure the deflection. The crack pattern was observed and analyzed. The experimental result shows that Beam 2 produced greater maximum load with 3.320kN, flexural strength with 0.664 N/mm2 and deflection with 0.330mm. The loss percentage of flexural strength increased as the depth of hollow section increased which are 28%, 40.79% and 49.13% for Beam 2, Beam 3 and Beam 4 respectively when compared to Beam 1. The decrement of deflection compared to Beam 1 are 5.71%, 11.43% and 34.0% for Beam 2, Beam 3 and Beam 4 respectively. First crack on the beam was reflected as the ultimate crack since the beam were unreinforced. Hence, the flexural strength and deflection depend on the second moment of inertia which then second moment of inertia depends on the neutral axis. In short, the beam with hollow section at the neutral axis is the suitable beam for future planning of construction due to higher ultimate load and deflection.by adding the reinforcement in any beam application, will be better because the ultimate load and deflection value will be bigger.
format Undergraduates Project Papers
author Afidatul Husna, Mohamad Syariff
author_facet Afidatul Husna, Mohamad Syariff
author_sort Afidatul Husna, Mohamad Syariff
title The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
title_short The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
title_full The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
title_fullStr The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
title_full_unstemmed The effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
title_sort effect of various position of cilcular hollow section on the strength of foamed concrete beam with processed spent bleaching as partial replacement of cement
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/27627/1/The%20effect%20of%20various%20position%20of%20cilcular%20hollow%20section%20on%20the%20strength%20of%20foamed.pdf
http://umpir.ump.edu.my/id/eprint/27627/
https://efind.ump.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=90907
_version_ 1657487857010343936
score 13.160551