Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system

Electrical resistance tomography (ERT) reconstructs internal resistance images of the field from electrical measurements on the surface. The objective of this paper is to obtain the tomogram of the liquid-gas regime of ERT system by using multiple excitation sources. A linear back projection algorit...

Full description

Saved in:
Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, M. F., Fuad, N. M., A. Ghani, Z. M., Zain, M. M., Noh, Mohd Anwar, Zawawi, M. S., Najib
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27377/7/Image%20reconstruction%20for%20liquid-gas%20regime.pdf
http://umpir.ump.edu.my/id/eprint/27377/
https://doi.org/10.1088/1757-899X/705/1/012025
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.27377
record_format eprints
spelling my.ump.umpir.273772020-01-16T04:46:57Z http://umpir.ump.edu.my/id/eprint/27377/ Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system Yasmin, Abdul Wahab M. F., Fuad N. M., A. Ghani Z. M., Zain M. M., Noh Mohd Anwar, Zawawi M. S., Najib TK Electrical engineering. Electronics Nuclear engineering Electrical resistance tomography (ERT) reconstructs internal resistance images of the field from electrical measurements on the surface. The objective of this paper is to obtain the tomogram of the liquid-gas regime of ERT system by using multiple excitation sources. A linear back projection algorithm was implemented as a basic algorithm. Then, it was modified to suit the implementation of multiple excitation sources. A liquid-gas regime in the steel pipe was used as a tested medium. The analysis and performance of the image reconstructed which applies multiple excitation sources were compared with the single excitation technique. As a common strategy applied a single excitation source and produce problem especially at the center of the pipe, this paper mainly focuses on image reconstruction of multiple excitation sources. As a conclusion, 50% of the excitation source cannot produce the image as expected. Tomograms that produced by using the single excitation source were much better than the images obtained by using 50% of the excitation source. IOP Publishing 2019 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/27377/7/Image%20reconstruction%20for%20liquid-gas%20regime.pdf Yasmin, Abdul Wahab and M. F., Fuad and N. M., A. Ghani and Z. M., Zain and M. M., Noh and Mohd Anwar, Zawawi and M. S., Najib (2019) Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system. In: IOP Conference Series: Materials Science and Engineering, 5th International Conference on Man Machine Systems, 26-27 August 2019 , Pulau Pinang, Malaysia. pp. 1-2., 705 (012025). ISSN 1757-899X https://doi.org/10.1088/1757-899X/705/1/012025
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
M. F., Fuad
N. M., A. Ghani
Z. M., Zain
M. M., Noh
Mohd Anwar, Zawawi
M. S., Najib
Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
description Electrical resistance tomography (ERT) reconstructs internal resistance images of the field from electrical measurements on the surface. The objective of this paper is to obtain the tomogram of the liquid-gas regime of ERT system by using multiple excitation sources. A linear back projection algorithm was implemented as a basic algorithm. Then, it was modified to suit the implementation of multiple excitation sources. A liquid-gas regime in the steel pipe was used as a tested medium. The analysis and performance of the image reconstructed which applies multiple excitation sources were compared with the single excitation technique. As a common strategy applied a single excitation source and produce problem especially at the center of the pipe, this paper mainly focuses on image reconstruction of multiple excitation sources. As a conclusion, 50% of the excitation source cannot produce the image as expected. Tomograms that produced by using the single excitation source were much better than the images obtained by using 50% of the excitation source.
format Conference or Workshop Item
author Yasmin, Abdul Wahab
M. F., Fuad
N. M., A. Ghani
Z. M., Zain
M. M., Noh
Mohd Anwar, Zawawi
M. S., Najib
author_facet Yasmin, Abdul Wahab
M. F., Fuad
N. M., A. Ghani
Z. M., Zain
M. M., Noh
Mohd Anwar, Zawawi
M. S., Najib
author_sort Yasmin, Abdul Wahab
title Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
title_short Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
title_full Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
title_fullStr Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
title_full_unstemmed Image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
title_sort image reconstruction for liquid-gas regime identification based on multiple excitation sources in electrical resistance tomography system
publisher IOP Publishing
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/27377/7/Image%20reconstruction%20for%20liquid-gas%20regime.pdf
http://umpir.ump.edu.my/id/eprint/27377/
https://doi.org/10.1088/1757-899X/705/1/012025
_version_ 1657487833292603392
score 13.160551