Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia

Simple urban residential building must meet the technical requirements set forth in the building and structure law number 28 of 2002. In the city of Bogor, especially in the densely populated village of Kayumanis, there are areas that have the potential of landslides. In that area, there are some ho...

Full description

Saved in:
Bibliographic Details
Main Authors: M., Lutfi, H., Arien, M., Hendrawati, Putra Jaya, Ramadhansyah, Noram Irwan, Ramli
Format: Conference or Workshop Item
Language:English
Published: 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26508/1/1.%20Assessment%20of%20safety%20performance%20level%20on%20simple%20urban.pdf
http://umpir.ump.edu.my/id/eprint/26508/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.26508
record_format eprints
spelling my.ump.umpir.265082019-11-20T06:30:22Z http://umpir.ump.edu.my/id/eprint/26508/ Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia M., Lutfi H., Arien M., Hendrawati Putra Jaya, Ramadhansyah Noram Irwan, Ramli TF Railroad engineering and operation Simple urban residential building must meet the technical requirements set forth in the building and structure law number 28 of 2002. In the city of Bogor, especially in the densely populated village of Kayumanis, there are areas that have the potential of landslides. In that area, there are some houses that have been damaged by the movement of land and landslides that can threaten the safety of its inhabitants. Therefore they need to stay aware about potential collapse of several parts of house structures, and then understand how to evacuate to safer area, outside of the house after the incident was stopped. Based on these conditions, it is necessary to evaluate buildings in accordance with FEMA on the safety level of buildings. The structure and modeling analysis using SAP 2000-V10 and Indonesia Standard. Specification of simple urban residential building using the reinforced concrete material with the quality of concrete (fc') 17 MPa, 15x15 cm column dimension, 15x18 cm beam dimension and 4D12 BJTP main reinforcement, and shear reinforcement D8-20. The results of the analysis of urban residential building structures shown in 3D form, obtained values for column structure elements almost close to failure are marked with orange color while for the element of the beam structure is declared safe marked with green color. From result of modeling analysis referring to FEMA 356 obtained value C0 = 1.0; C1 = 1.378; C2 = 1.0; C3 = 1.0; Sa = 1.011; and Te = 0.2206, which states the value of the displacement target is 0.02 m which is categorized to be at ‘The Life Safety’ (LS) performance level. This means that if there is a movement of land, the structure of the house is declared stable and has adequate service capacity and damage non-structural part is still controlled. 2019 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26508/1/1.%20Assessment%20of%20safety%20performance%20level%20on%20simple%20urban.pdf M., Lutfi and H., Arien and M., Hendrawati and Putra Jaya, Ramadhansyah and Noram Irwan, Ramli (2019) Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia. In: Proceedings of 3rd National Conference on Wind & Earthquake Engineering and 1st International Seminar On Sustainable Construction Engineering (NCWE & ISSCE 2019), 12-13 July 2019 , Kuala Lumpur, Malaysia. pp. 9-15..
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TF Railroad engineering and operation
spellingShingle TF Railroad engineering and operation
M., Lutfi
H., Arien
M., Hendrawati
Putra Jaya, Ramadhansyah
Noram Irwan, Ramli
Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
description Simple urban residential building must meet the technical requirements set forth in the building and structure law number 28 of 2002. In the city of Bogor, especially in the densely populated village of Kayumanis, there are areas that have the potential of landslides. In that area, there are some houses that have been damaged by the movement of land and landslides that can threaten the safety of its inhabitants. Therefore they need to stay aware about potential collapse of several parts of house structures, and then understand how to evacuate to safer area, outside of the house after the incident was stopped. Based on these conditions, it is necessary to evaluate buildings in accordance with FEMA on the safety level of buildings. The structure and modeling analysis using SAP 2000-V10 and Indonesia Standard. Specification of simple urban residential building using the reinforced concrete material with the quality of concrete (fc') 17 MPa, 15x15 cm column dimension, 15x18 cm beam dimension and 4D12 BJTP main reinforcement, and shear reinforcement D8-20. The results of the analysis of urban residential building structures shown in 3D form, obtained values for column structure elements almost close to failure are marked with orange color while for the element of the beam structure is declared safe marked with green color. From result of modeling analysis referring to FEMA 356 obtained value C0 = 1.0; C1 = 1.378; C2 = 1.0; C3 = 1.0; Sa = 1.011; and Te = 0.2206, which states the value of the displacement target is 0.02 m which is categorized to be at ‘The Life Safety’ (LS) performance level. This means that if there is a movement of land, the structure of the house is declared stable and has adequate service capacity and damage non-structural part is still controlled.
format Conference or Workshop Item
author M., Lutfi
H., Arien
M., Hendrawati
Putra Jaya, Ramadhansyah
Noram Irwan, Ramli
author_facet M., Lutfi
H., Arien
M., Hendrawati
Putra Jaya, Ramadhansyah
Noram Irwan, Ramli
author_sort M., Lutfi
title Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
title_short Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
title_full Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
title_fullStr Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
title_full_unstemmed Assessment of safety performance level on simple urban residential building: Case study at Bogor City Indonesia
title_sort assessment of safety performance level on simple urban residential building: case study at bogor city indonesia
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/26508/1/1.%20Assessment%20of%20safety%20performance%20level%20on%20simple%20urban.pdf
http://umpir.ump.edu.my/id/eprint/26508/
_version_ 1651866978625781760
score 13.15806