Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates

Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and...

Full description

Saved in:
Bibliographic Details
Main Authors: Norazlianie, Sazali, W. N. W., Salleh, A. F., Ismail, Murakamid, Hideyuki, Iwamotoe, Yuji
Format: Article
Language:English
Published: Taylor & Francis 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf
http://umpir.ump.edu.my/id/eprint/26236/
https://doi.org/10.1080/00986445.2019.1631163
https://doi.org/10.1080/00986445.2019.1631163
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.26236
record_format eprints
spelling my.ump.umpir.262362019-10-30T01:51:18Z http://umpir.ump.edu.my/id/eprint/26236/ Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates Norazlianie, Sazali W. N. W., Salleh A. F., Ismail Murakamid, Hideyuki Iwamotoe, Yuji QD Chemistry Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and additive, respectively. Previous study has proved that properties of PI/NCC can be altered by changing the carbonization parameter, i.e. time, temperature, and environment. PI/NCC deposition on the ceramic tubular support was employed to produce diverse TCMs for gas separation via simple carbonization process. In this study, manipulation of heating rate was done to observe the effect of TCMs on gas permeation by setting the heating rate at 1, 3, 5, and 7C min–1. It was proved that heating rate during PI/NCC-based carbon membrane fabrication played a significant role in gas ideal selectivity test. In addition, heating rate at (3C min–1) showed an improvement in the membrane ideal selectivity but a reduction in the permeability. Taylor & Francis 2019 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf Norazlianie, Sazali and W. N. W., Salleh and A. F., Ismail and Murakamid, Hideyuki and Iwamotoe, Yuji (2019) Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates. Chemical Engineering Communications. pp. 1-11. ISSN 1563-5201 https://doi.org/10.1080/00986445.2019.1631163 https://doi.org/10.1080/00986445.2019.1631163
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
description Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and additive, respectively. Previous study has proved that properties of PI/NCC can be altered by changing the carbonization parameter, i.e. time, temperature, and environment. PI/NCC deposition on the ceramic tubular support was employed to produce diverse TCMs for gas separation via simple carbonization process. In this study, manipulation of heating rate was done to observe the effect of TCMs on gas permeation by setting the heating rate at 1, 3, 5, and 7C min–1. It was proved that heating rate during PI/NCC-based carbon membrane fabrication played a significant role in gas ideal selectivity test. In addition, heating rate at (3C min–1) showed an improvement in the membrane ideal selectivity but a reduction in the permeability.
format Article
author Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
author_facet Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
author_sort Norazlianie, Sazali
title Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_short Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_full Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_fullStr Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_full_unstemmed Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_sort oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: impact of heating rates
publisher Taylor & Francis
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf
http://umpir.ump.edu.my/id/eprint/26236/
https://doi.org/10.1080/00986445.2019.1631163
https://doi.org/10.1080/00986445.2019.1631163
_version_ 1651866952348467200
score 13.160551