Shrinkage deformation of different shape of foamed concrete specimen

In construction field, the most important element is concrete. Majority of construction in Malaysia use the concrete and the improvement of concrete technology is very important. Example of concrete technology improvement is foamed concrete. Foamed concrete is additional of foaming agent in the con...

Full description

Saved in:
Bibliographic Details
Main Author: Zuhairi, Zakaria
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2610/1/ZUHAIRI_BIN_ZAKARIA.PDF
http://umpir.ump.edu.my/id/eprint/2610/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.2610
record_format eprints
spelling my.ump.umpir.26102021-06-24T07:15:17Z http://umpir.ump.edu.my/id/eprint/2610/ Shrinkage deformation of different shape of foamed concrete specimen Zuhairi, Zakaria TA Engineering (General). Civil engineering (General) In construction field, the most important element is concrete. Majority of construction in Malaysia use the concrete and the improvement of concrete technology is very important. Example of concrete technology improvement is foamed concrete. Foamed concrete is additional of foaming agent in the concrete mixture to control the concrete density and the foamed concrete do not used the course aggregate. The foaming agent used to trap the air to reduce the concrete density. The strength of foamed concrete is lower than normal concrete and it is suitable to be used at the uncritical structure in the construction. The foamed agent also expose to crack effected by drying shrinkage. Some of the factors causes the drying shrinkage are investigated. Two factors of drying shrinkage investigated in this study are different density of foamed concrete and different shapes of concrete specimens. Prism sized 100mm x 100mm x 500mm, cylinder sized 150mm 0 x 300mm and 150mm cube for 1200 kg/m3 and 1600 kg/m3 density were produced throughout this experiment. The uses of prism and cylinder specimens are because it is normal shape of concrete structure with different surface expose to environmental for shrinkage observation. The cube was used for compressive strength test to prove the targeted density. The result of compressive strength test shows the increments of concrete density produced high strength of concrete. On the other hand, the increments of concrete density reduce the shrinkage value as well as the reduction of surface exposes to the environmental. 2010-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2610/1/ZUHAIRI_BIN_ZAKARIA.PDF Zuhairi, Zakaria (2010) Shrinkage deformation of different shape of foamed concrete specimen. Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Zuhairi, Zakaria
Shrinkage deformation of different shape of foamed concrete specimen
description In construction field, the most important element is concrete. Majority of construction in Malaysia use the concrete and the improvement of concrete technology is very important. Example of concrete technology improvement is foamed concrete. Foamed concrete is additional of foaming agent in the concrete mixture to control the concrete density and the foamed concrete do not used the course aggregate. The foaming agent used to trap the air to reduce the concrete density. The strength of foamed concrete is lower than normal concrete and it is suitable to be used at the uncritical structure in the construction. The foamed agent also expose to crack effected by drying shrinkage. Some of the factors causes the drying shrinkage are investigated. Two factors of drying shrinkage investigated in this study are different density of foamed concrete and different shapes of concrete specimens. Prism sized 100mm x 100mm x 500mm, cylinder sized 150mm 0 x 300mm and 150mm cube for 1200 kg/m3 and 1600 kg/m3 density were produced throughout this experiment. The uses of prism and cylinder specimens are because it is normal shape of concrete structure with different surface expose to environmental for shrinkage observation. The cube was used for compressive strength test to prove the targeted density. The result of compressive strength test shows the increments of concrete density produced high strength of concrete. On the other hand, the increments of concrete density reduce the shrinkage value as well as the reduction of surface exposes to the environmental.
format Undergraduates Project Papers
author Zuhairi, Zakaria
author_facet Zuhairi, Zakaria
author_sort Zuhairi, Zakaria
title Shrinkage deformation of different shape of foamed concrete specimen
title_short Shrinkage deformation of different shape of foamed concrete specimen
title_full Shrinkage deformation of different shape of foamed concrete specimen
title_fullStr Shrinkage deformation of different shape of foamed concrete specimen
title_full_unstemmed Shrinkage deformation of different shape of foamed concrete specimen
title_sort shrinkage deformation of different shape of foamed concrete specimen
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/2610/1/ZUHAIRI_BIN_ZAKARIA.PDF
http://umpir.ump.edu.my/id/eprint/2610/
_version_ 1703960710122307584
score 13.18916