TEC variations at GPS stations over high-latitude and at the equatorial region
This paper analyzes and compares TEC measurement at GPS stations belonging to UKM installed at Husafell, Iceland (64° 40' N, -21° 1' E) in the high-latitude and UKM (2° 55' N, 101° 46' E) in the equatorial latitude. A high performance dual-frequency GPS receiver with chock-ring a...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2011
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/25923/1/TEC%20variations%20at%20GPS%20stations%20over%20high-latitude%20and%20at%20the%20equatorial%20region.pdf http://umpir.ump.edu.my/id/eprint/25923/ https://doi.org/10.1109/IConSpace.2011.6015865 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.25923 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.259232019-10-17T01:02:09Z http://umpir.ump.edu.my/id/eprint/25923/ TEC variations at GPS stations over high-latitude and at the equatorial region Mardina, Abdullah Sabirin, Abdullah Siti Aminah, Bahari Asnawi, . Suparta, Wayan Ahmad Faizal, Mohd Zain Kadokura, Akira Bjornsson, Gunnlaugur TS Manufactures This paper analyzes and compares TEC measurement at GPS stations belonging to UKM installed at Husafell, Iceland (64° 40' N, -21° 1' E) in the high-latitude and UKM (2° 55' N, 101° 46' E) in the equatorial latitude. A high performance dual-frequency GPS receiver with chock-ring antenna was used in this study. GPS data for the whole year of 2009 were used in this analysis. BGS's Bernese Processing Engine (BPE)'s precise point positioning (PPP) mode was used to generate TEC at the single station with the zero-difference technique for differencing level of choice. Comparison of the maximum value of TEC between Husafell, Iceland for high-latitude and UKM, Malaysia for the equatorial region was carried out. Results show that the maximum value of TEC at high-latitude reaches its maximum at post local noon which is similar to that over the equatorial region. TEC values reach their maximum at 13:00 UTC at Husafell while at UKM it is at 06:00 UTC (14:00 LT). It is observed that TEC at UKM's equatorial station is approximately twice compared to the Husafell station. IEEE 2011 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25923/1/TEC%20variations%20at%20GPS%20stations%20over%20high-latitude%20and%20at%20the%20equatorial%20region.pdf Mardina, Abdullah and Sabirin, Abdullah and Siti Aminah, Bahari and Asnawi, . and Suparta, Wayan and Ahmad Faizal, Mohd Zain and Kadokura, Akira and Bjornsson, Gunnlaugur (2011) TEC variations at GPS stations over high-latitude and at the equatorial region. In: Proceeding of the 2011 IEEE International Conference on Space Science and Communication (IconSpace), 12-13 July 2011 , Penang. pp. 121-124. (6015865). ISSN 2165-431X ISBN 978-1-4577-0564-9 https://doi.org/10.1109/IConSpace.2011.6015865 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TS Manufactures |
spellingShingle |
TS Manufactures Mardina, Abdullah Sabirin, Abdullah Siti Aminah, Bahari Asnawi, . Suparta, Wayan Ahmad Faizal, Mohd Zain Kadokura, Akira Bjornsson, Gunnlaugur TEC variations at GPS stations over high-latitude and at the equatorial region |
description |
This paper analyzes and compares TEC measurement at GPS stations belonging to UKM installed at Husafell, Iceland (64° 40' N, -21° 1' E) in the high-latitude and UKM (2° 55' N, 101° 46' E) in the equatorial latitude. A high performance dual-frequency GPS receiver with chock-ring antenna was used in this study. GPS data for the whole year of 2009 were used in this analysis. BGS's Bernese Processing Engine (BPE)'s precise point positioning (PPP) mode was used to generate TEC at the single station with the zero-difference technique for differencing level of choice. Comparison of the maximum value of TEC between Husafell, Iceland for high-latitude and UKM, Malaysia for the equatorial region was carried out. Results show that the maximum value of TEC at high-latitude reaches its maximum at post local noon which is similar to that over the equatorial region. TEC values reach their maximum at 13:00 UTC at Husafell while at UKM it is at 06:00 UTC (14:00 LT). It is observed that TEC at UKM's equatorial station is approximately twice compared to the Husafell station. |
format |
Conference or Workshop Item |
author |
Mardina, Abdullah Sabirin, Abdullah Siti Aminah, Bahari Asnawi, . Suparta, Wayan Ahmad Faizal, Mohd Zain Kadokura, Akira Bjornsson, Gunnlaugur |
author_facet |
Mardina, Abdullah Sabirin, Abdullah Siti Aminah, Bahari Asnawi, . Suparta, Wayan Ahmad Faizal, Mohd Zain Kadokura, Akira Bjornsson, Gunnlaugur |
author_sort |
Mardina, Abdullah |
title |
TEC variations at GPS stations over high-latitude and at the equatorial region |
title_short |
TEC variations at GPS stations over high-latitude and at the equatorial region |
title_full |
TEC variations at GPS stations over high-latitude and at the equatorial region |
title_fullStr |
TEC variations at GPS stations over high-latitude and at the equatorial region |
title_full_unstemmed |
TEC variations at GPS stations over high-latitude and at the equatorial region |
title_sort |
tec variations at gps stations over high-latitude and at the equatorial region |
publisher |
IEEE |
publishDate |
2011 |
url |
http://umpir.ump.edu.my/id/eprint/25923/1/TEC%20variations%20at%20GPS%20stations%20over%20high-latitude%20and%20at%20the%20equatorial%20region.pdf http://umpir.ump.edu.my/id/eprint/25923/ https://doi.org/10.1109/IConSpace.2011.6015865 |
_version_ |
1648741221482364928 |
score |
13.211869 |