Impact response of multi slotted square column
This work investigates the impact response of multi slotted square hollow section column. Abaqus Explicit finite element code was used to simulate the response of this structure subjected to varying impact speeds. A comparative study with the standard plain square column was carried out and it was f...
Saved in:
Main Authors: | , , , |
---|---|
格式: | Article |
语言: | English |
出版: |
Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia.
2011
|
主题: | |
在线阅读: | http://umpir.ump.edu.my/id/eprint/25642/1/Impact%20response%20of%20multi%20slotted%20square%20column.pdf http://umpir.ump.edu.my/id/eprint/25642/ https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf |
标签: |
添加标签
没有标签, 成为第一个标记此记录!
|
id |
my.ump.umpir.25642 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.256422020-02-14T03:49:20Z http://umpir.ump.edu.my/id/eprint/25642/ Impact response of multi slotted square column Amir Radzi, Ab. Ghani M. A., Hasan M., Hamdi Zahari, Taha TJ Mechanical engineering and machinery This work investigates the impact response of multi slotted square hollow section column. Abaqus Explicit finite element code was used to simulate the response of this structure subjected to varying impact speeds. A comparative study with the standard plain square column was carried out and it was found that the slotted column exhibited lower initial peak force (IPF) as compared to the plain column. Mean forces for both types of columns remained the same. Both types of columns exhibited different IPFs with different impact speeds. The number of slots on the slotted column also influenced the formation of folds during the progressive crushing. The low IPF is an important feature when designing for occupant and critical goods safety. Based on these preliminary findings, it is believed that impact performance of standard square column can be improved over a wider range of impact speeds and impact mass by correct placement of slots. Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia. 2011 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/25642/1/Impact%20response%20of%20multi%20slotted%20square%20column.pdf Amir Radzi, Ab. Ghani and M. A., Hasan and M., Hamdi and Zahari, Taha (2011) Impact response of multi slotted square column. Journal of Mechanical Engineering, 8 (2). pp. 71-91. ISSN 1823-5514. (Published) https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Amir Radzi, Ab. Ghani M. A., Hasan M., Hamdi Zahari, Taha Impact response of multi slotted square column |
description |
This work investigates the impact response of multi slotted square hollow section column. Abaqus Explicit finite element code was used to simulate the response of this structure subjected to varying impact speeds. A comparative study with the standard plain square column was carried out and it was found that the slotted column exhibited lower initial peak force (IPF) as compared to the plain column. Mean forces for both types of columns remained the same. Both types of columns exhibited different IPFs with different impact speeds. The number of slots on the slotted column also influenced the formation of folds during the progressive crushing. The low IPF is an important feature when designing for occupant and critical goods safety. Based on these preliminary findings, it is believed that impact performance of standard square column can be improved over a wider range of impact speeds and impact mass by correct placement of slots. |
format |
Article |
author |
Amir Radzi, Ab. Ghani M. A., Hasan M., Hamdi Zahari, Taha |
author_facet |
Amir Radzi, Ab. Ghani M. A., Hasan M., Hamdi Zahari, Taha |
author_sort |
Amir Radzi, Ab. Ghani |
title |
Impact response of multi slotted square column |
title_short |
Impact response of multi slotted square column |
title_full |
Impact response of multi slotted square column |
title_fullStr |
Impact response of multi slotted square column |
title_full_unstemmed |
Impact response of multi slotted square column |
title_sort |
impact response of multi slotted square column |
publisher |
Faculty of Mechanical Engineering, Universiti Teknologi MARA (UiTM), Malaysia. |
publishDate |
2011 |
url |
http://umpir.ump.edu.my/id/eprint/25642/1/Impact%20response%20of%20multi%20slotted%20square%20column.pdf http://umpir.ump.edu.my/id/eprint/25642/ https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf https://www.researchgate.net/profile/MA_Hassan/publication/257536097_Impact_response_of_multi_slotted_square_column/links/00b495256468834237000000.pdf |
_version_ |
1822920934432964608 |
score |
13.251813 |