Respiration rate detection based on intensity modulation using plastic optical fiber

This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Anwar, Zawawi, Nurul Sufia, Nor Ziran, Hadi, Manap
Format: Conference or Workshop Item
Language:English
Published: EDP Sciences 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24165/1/Respiration%20rate%20detection%20based%20on%20intensity%20modulation%20using%20plastic%20optical%20fiber.pdf
http://umpir.ump.edu.my/id/eprint/24165/
http://www.epj-conferences.org/articles/epjconf/pdf/2017/31/epjconf_incape2017_01010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.24165
record_format eprints
spelling my.ump.umpir.241652019-05-21T02:39:44Z http://umpir.ump.edu.my/id/eprint/24165/ Respiration rate detection based on intensity modulation using plastic optical fiber Mohd Anwar, Zawawi Nurul Sufia, Nor Ziran Hadi, Manap T Technology (General) TK Electrical engineering. Electronics Nuclear engineering This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring. EDP Sciences 2017-11 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24165/1/Respiration%20rate%20detection%20based%20on%20intensity%20modulation%20using%20plastic%20optical%20fiber.pdf Mohd Anwar, Zawawi and Nurul Sufia, Nor Ziran and Hadi, Manap (2017) Respiration rate detection based on intensity modulation using plastic optical fiber. In: International Conference on Applied Photonics and Electronics (InCAPE 2017), 9-10 August 2017 , Port Dickson, N. Sembilan. pp. 1-4., 162. ISSN 2101-6275 http://www.epj-conferences.org/articles/epjconf/pdf/2017/31/epjconf_incape2017_01010.pdf
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Mohd Anwar, Zawawi
Nurul Sufia, Nor Ziran
Hadi, Manap
Respiration rate detection based on intensity modulation using plastic optical fiber
description This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.
format Conference or Workshop Item
author Mohd Anwar, Zawawi
Nurul Sufia, Nor Ziran
Hadi, Manap
author_facet Mohd Anwar, Zawawi
Nurul Sufia, Nor Ziran
Hadi, Manap
author_sort Mohd Anwar, Zawawi
title Respiration rate detection based on intensity modulation using plastic optical fiber
title_short Respiration rate detection based on intensity modulation using plastic optical fiber
title_full Respiration rate detection based on intensity modulation using plastic optical fiber
title_fullStr Respiration rate detection based on intensity modulation using plastic optical fiber
title_full_unstemmed Respiration rate detection based on intensity modulation using plastic optical fiber
title_sort respiration rate detection based on intensity modulation using plastic optical fiber
publisher EDP Sciences
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/24165/1/Respiration%20rate%20detection%20based%20on%20intensity%20modulation%20using%20plastic%20optical%20fiber.pdf
http://umpir.ump.edu.my/id/eprint/24165/
http://www.epj-conferences.org/articles/epjconf/pdf/2017/31/epjconf_incape2017_01010.pdf
_version_ 1643669773160022016
score 13.214268