Initial study of multiple excitation source for electrical resistance tomography in steel pipe application

Tomography is a method of reconstructing the image of an object’s interest within the sensing zone. Electrical resistance tomography (ERT) system operates when using current as an excitation source and output voltage is meas-ured at the detection electrode and the research will result in the changes...

Full description

Saved in:
Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Syazwani Amanina, Syakyean, Zainah, Md. Zain, Nor Maniha, Abd Ghani, Maziyah, Mat Noh
Format: Book Section
Language:English
English
English
Published: Springer Singapore 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/22973/1/86.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical.pdf
http://umpir.ump.edu.my/id/eprint/22973/9/47.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf
http://umpir.ump.edu.my/id/eprint/22973/10/47.1%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf
http://umpir.ump.edu.my/id/eprint/22973/
https://link.springer.com/chapter/10.1007/978-981-13-3708-6_30
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.22973
record_format eprints
spelling my.ump.umpir.229732019-05-27T08:25:27Z http://umpir.ump.edu.my/id/eprint/22973/ Initial study of multiple excitation source for electrical resistance tomography in steel pipe application Yasmin, Abdul Wahab Syazwani Amanina, Syakyean Zainah, Md. Zain Nor Maniha, Abd Ghani Maziyah, Mat Noh TK Electrical engineering. Electronics Nuclear engineering Tomography is a method of reconstructing the image of an object’s interest within the sensing zone. Electrical resistance tomography (ERT) system operates when using current as an excitation source and output voltage is meas-ured at the detection electrode and the research will result in the changes of elec-tric potential distribution. A lot of researches have been made using ERT to iden-tify a liquid-gas regime in the steel pipe focused on improving image resolution of the regime. However, a common excitation source of ERT used only a single excitation. Thus, this research uses COMSOL Multiphysics as a platform for sim-ulation of multiple excitations of electrical resistance tomography for liquid-gas regime identification in steel pipe. The analysis and performance of new simula-tion which applies multiple excitation sources have been compared with the sin-gle excitation. Besides, the project is limited to 54mm inner diameter of the steel pipe. As a conclusion, 50% of the excitation source can increase the image reso-lution of those regimes especially in the middle of the steel pipe. Springer Singapore 2018 Book Section PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/22973/1/86.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical.pdf pdf en http://umpir.ump.edu.my/id/eprint/22973/9/47.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf pdf en http://umpir.ump.edu.my/id/eprint/22973/10/47.1%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf Yasmin, Abdul Wahab and Syazwani Amanina, Syakyean and Zainah, Md. Zain and Nor Maniha, Abd Ghani and Maziyah, Mat Noh (2018) Initial study of multiple excitation source for electrical resistance tomography in steel pipe application. In: Proceedings of the 10th National Technical Seminar on Underwater System Technology 2018. Lecture Notes in Electrical Engineering . Springer Singapore, Singapore, pp. 353-359. ISBN 978-981-13-3708-6 https://link.springer.com/chapter/10.1007/978-981-13-3708-6_30 DOI: https://doi.org/10.1007/978-981-13-3708-6_30
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Syazwani Amanina, Syakyean
Zainah, Md. Zain
Nor Maniha, Abd Ghani
Maziyah, Mat Noh
Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
description Tomography is a method of reconstructing the image of an object’s interest within the sensing zone. Electrical resistance tomography (ERT) system operates when using current as an excitation source and output voltage is meas-ured at the detection electrode and the research will result in the changes of elec-tric potential distribution. A lot of researches have been made using ERT to iden-tify a liquid-gas regime in the steel pipe focused on improving image resolution of the regime. However, a common excitation source of ERT used only a single excitation. Thus, this research uses COMSOL Multiphysics as a platform for sim-ulation of multiple excitations of electrical resistance tomography for liquid-gas regime identification in steel pipe. The analysis and performance of new simula-tion which applies multiple excitation sources have been compared with the sin-gle excitation. Besides, the project is limited to 54mm inner diameter of the steel pipe. As a conclusion, 50% of the excitation source can increase the image reso-lution of those regimes especially in the middle of the steel pipe.
format Book Section
author Yasmin, Abdul Wahab
Syazwani Amanina, Syakyean
Zainah, Md. Zain
Nor Maniha, Abd Ghani
Maziyah, Mat Noh
author_facet Yasmin, Abdul Wahab
Syazwani Amanina, Syakyean
Zainah, Md. Zain
Nor Maniha, Abd Ghani
Maziyah, Mat Noh
author_sort Yasmin, Abdul Wahab
title Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
title_short Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
title_full Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
title_fullStr Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
title_full_unstemmed Initial study of multiple excitation source for electrical resistance tomography in steel pipe application
title_sort initial study of multiple excitation source for electrical resistance tomography in steel pipe application
publisher Springer Singapore
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/22973/1/86.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical.pdf
http://umpir.ump.edu.my/id/eprint/22973/9/47.%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf
http://umpir.ump.edu.my/id/eprint/22973/10/47.1%20Initial%20study%20of%20multiple%20excitation%20source%20for%20electrical%20resistance%20tomography%20in%20steel%20pipe%20application.pdf
http://umpir.ump.edu.my/id/eprint/22973/
https://link.springer.com/chapter/10.1007/978-981-13-3708-6_30
_version_ 1643669487374827520
score 13.160551