Design an air conditioning system for UMP mosque

This project is carried out to design a suitable air conditioning system for UMP Mosque. The architectural drawing of UMP mosque is studied first to choose the best air conditioner to be installed in UMP Mosque. Tropical country such as Malaysia is hot and humid. Taking UMP Mosque as an example, dur...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Hilmi, Tajud Hassan
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/22510/1/15.Design%20an%20air%20conditioning%20system%20for%20UMP%20mosque.pdf
http://umpir.ump.edu.my/id/eprint/22510/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.22510
record_format eprints
spelling my.ump.umpir.225102023-09-07T07:31:56Z http://umpir.ump.edu.my/id/eprint/22510/ Design an air conditioning system for UMP mosque Mohd Hilmi, Tajud Hassan TH Building construction This project is carried out to design a suitable air conditioning system for UMP Mosque. The architectural drawing of UMP mosque is studied first to choose the best air conditioner to be installed in UMP Mosque. Tropical country such as Malaysia is hot and humid. Taking UMP Mosque as an example, during Friday Prayer there is about 1300 Muslims perform Friday Prayer inside UMP Mosque. This situation makes the Muslims feel not comfortable with this condition. Therefore an air conditioning system should be installed in the UMP Mosque to provide comfort to the occupants. The objective of this project is to calculate the heat gains in UMP Mosque. The purpose of calculating the heat gain is to determine the total cooling load required. Another objective is to design a suitable air conditioning system for UMP Mosque. Designing the ductwork, determination of duct size, selection of suitable space to locate the air handling unit (AWl) is done in the design of the air conditioning system. The highest heat gain in UMP Mosque is at 4.00 pm on the daily basis. The total heat gain at 4.00 pm hour is 171.8 W. However, the peak heat gain of 781.4 kW occurs during Friday prayer. Thus, the value of total heat gain during Friday Prayer is used to design the air conditioning system for TJIMP Mosque. The AHUs used are unitary system and each AHU connected with one duct. 2009-05 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/22510/1/15.Design%20an%20air%20conditioning%20system%20for%20UMP%20mosque.pdf Mohd Hilmi, Tajud Hassan (2009) Design an air conditioning system for UMP mosque. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TH Building construction
spellingShingle TH Building construction
Mohd Hilmi, Tajud Hassan
Design an air conditioning system for UMP mosque
description This project is carried out to design a suitable air conditioning system for UMP Mosque. The architectural drawing of UMP mosque is studied first to choose the best air conditioner to be installed in UMP Mosque. Tropical country such as Malaysia is hot and humid. Taking UMP Mosque as an example, during Friday Prayer there is about 1300 Muslims perform Friday Prayer inside UMP Mosque. This situation makes the Muslims feel not comfortable with this condition. Therefore an air conditioning system should be installed in the UMP Mosque to provide comfort to the occupants. The objective of this project is to calculate the heat gains in UMP Mosque. The purpose of calculating the heat gain is to determine the total cooling load required. Another objective is to design a suitable air conditioning system for UMP Mosque. Designing the ductwork, determination of duct size, selection of suitable space to locate the air handling unit (AWl) is done in the design of the air conditioning system. The highest heat gain in UMP Mosque is at 4.00 pm on the daily basis. The total heat gain at 4.00 pm hour is 171.8 W. However, the peak heat gain of 781.4 kW occurs during Friday prayer. Thus, the value of total heat gain during Friday Prayer is used to design the air conditioning system for TJIMP Mosque. The AHUs used are unitary system and each AHU connected with one duct.
format Undergraduates Project Papers
author Mohd Hilmi, Tajud Hassan
author_facet Mohd Hilmi, Tajud Hassan
author_sort Mohd Hilmi, Tajud Hassan
title Design an air conditioning system for UMP mosque
title_short Design an air conditioning system for UMP mosque
title_full Design an air conditioning system for UMP mosque
title_fullStr Design an air conditioning system for UMP mosque
title_full_unstemmed Design an air conditioning system for UMP mosque
title_sort design an air conditioning system for ump mosque
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/22510/1/15.Design%20an%20air%20conditioning%20system%20for%20UMP%20mosque.pdf
http://umpir.ump.edu.my/id/eprint/22510/
_version_ 1778161063233060864
score 13.209306