Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles

The performance of compact fin-and-flat tube heat exchangers (HE) can be affected by many geometrical and processing factors and one of them is tube inclination angle. However, the effect of flat tube inclination angle on the thermal-hydraulic performance of the HE is not fully examined. This pa...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Y., Adam, A. N., Oumer, Azri, Alias, M., Ishak, M. M., Noor
Format: Article
Language:English
Published: Universiti Malaysia Pahang 2017
Online Access:http://umpir.ump.edu.my/id/eprint/20243/1/fkm-2017-oumer-Investigation%20of%20Thermal-Hydraulic%20Performance%20in%20Flat%20Tube.pdf
http://umpir.ump.edu.my/id/eprint/20243/
https://doi.org/10.15282/ijame.14.3.2017.12.0359
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.20243
record_format eprints
spelling my.ump.umpir.202432018-01-19T08:00:43Z http://umpir.ump.edu.my/id/eprint/20243/ Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles A. Y., Adam A. N., Oumer Azri, Alias M., Ishak M. M., Noor The performance of compact fin-and-flat tube heat exchangers (HE) can be affected by many geometrical and processing factors and one of them is tube inclination angle. However, the effect of flat tube inclination angle on the thermal-hydraulic performance of the HE is not fully examined. This paper investigates the effects of flat tube inclination angles on heat transfer and pressure drop characteristics of fined flat tube HE when the tubes are deployed in in-line and staggered arrangements. A symmetric numerical method based on FLUENT software was carried out with six different tube inclination angles (0°, 30°, 60°, 90°, 120°, and 150°) in moderately high Reynolds number. From the results, it was observed that heat transfer coefficient increased with the augmentation of the tube inclination angle from 0o to 90o and decreased for 120o and 150o. With the increase of tube inclination angle, the average Nusselt number rose by 36.3%. This might be due to the reason that the tube surface area increases with the inclination angle, which also results in the largest increment of the pressure drop by 42.0%. Overall, the 90o tube inclination angle showed the highest enhancement in heat transfer for both inline and staggered configurations with a maximum enhancement of 41.2% for in-line and 32.2% for staggered arrangements. However, the heat transfer enhancements were accompanied by high-pressure drop penalties of up to 44.2% and 42.6% for in-line and staggered arrangements, respectively. Therefore, inclining the tubes at 90o is recommended where high heat transfer is required. On the other hand, 0o tube inclination angle is recommended where pumping power is a crucial issue. Universiti Malaysia Pahang 2017 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/20243/1/fkm-2017-oumer-Investigation%20of%20Thermal-Hydraulic%20Performance%20in%20Flat%20Tube.pdf A. Y., Adam and A. N., Oumer and Azri, Alias and M., Ishak and M. M., Noor (2017) Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles. International Journal of Automotive and Mechanical Engineering (IJAME), 14 (3). pp. 4542-4560. ISSN 1985-9325(Print); 2180-1606 (Online) https://doi.org/10.15282/ijame.14.3.2017.12.0359 doi: 10.15282/ijame.14.3.2017.12.0359
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
description The performance of compact fin-and-flat tube heat exchangers (HE) can be affected by many geometrical and processing factors and one of them is tube inclination angle. However, the effect of flat tube inclination angle on the thermal-hydraulic performance of the HE is not fully examined. This paper investigates the effects of flat tube inclination angles on heat transfer and pressure drop characteristics of fined flat tube HE when the tubes are deployed in in-line and staggered arrangements. A symmetric numerical method based on FLUENT software was carried out with six different tube inclination angles (0°, 30°, 60°, 90°, 120°, and 150°) in moderately high Reynolds number. From the results, it was observed that heat transfer coefficient increased with the augmentation of the tube inclination angle from 0o to 90o and decreased for 120o and 150o. With the increase of tube inclination angle, the average Nusselt number rose by 36.3%. This might be due to the reason that the tube surface area increases with the inclination angle, which also results in the largest increment of the pressure drop by 42.0%. Overall, the 90o tube inclination angle showed the highest enhancement in heat transfer for both inline and staggered configurations with a maximum enhancement of 41.2% for in-line and 32.2% for staggered arrangements. However, the heat transfer enhancements were accompanied by high-pressure drop penalties of up to 44.2% and 42.6% for in-line and staggered arrangements, respectively. Therefore, inclining the tubes at 90o is recommended where high heat transfer is required. On the other hand, 0o tube inclination angle is recommended where pumping power is a crucial issue.
format Article
author A. Y., Adam
A. N., Oumer
Azri, Alias
M., Ishak
M. M., Noor
spellingShingle A. Y., Adam
A. N., Oumer
Azri, Alias
M., Ishak
M. M., Noor
Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
author_facet A. Y., Adam
A. N., Oumer
Azri, Alias
M., Ishak
M. M., Noor
author_sort A. Y., Adam
title Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
title_short Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
title_full Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
title_fullStr Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
title_full_unstemmed Investigation of Thermal-Hydraulic Performance in Flat Tube Heat Exchangers at Various Tube Inclination Angles
title_sort investigation of thermal-hydraulic performance in flat tube heat exchangers at various tube inclination angles
publisher Universiti Malaysia Pahang
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/20243/1/fkm-2017-oumer-Investigation%20of%20Thermal-Hydraulic%20Performance%20in%20Flat%20Tube.pdf
http://umpir.ump.edu.my/id/eprint/20243/
https://doi.org/10.15282/ijame.14.3.2017.12.0359
_version_ 1643668824363368448
score 13.160551