Malaysian sewerage systems are designed according to the Malaysian Standard MS 1228:1991. Manholes may be flooded and overflow if the peak flow of sewage is not properly addressed during sewerage system design. The purpose of the overall research is to analyse the per capita flow as well as design c...

Full description

Saved in:
Bibliographic Details
Main Authors: Ngien, S. K., Yap, H. T.
Format: Conference or Workshop Item
Language:English
English
Published: 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/19848/1/YapHiewThong_FluidsChE%202017%20abstract%20v1.docx
http://umpir.ump.edu.my/id/eprint/19848/3/Flow%20Design%20of%20Sewerage%20System%20%E2%80%93%20A%20Case.pdf
http://umpir.ump.edu.my/id/eprint/19848/
http://dx.doi.org/10.17485/ijst%2F2017%2Fv10i2%2F110375
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.19848
record_format eprints
spelling my.ump.umpir.198482018-04-17T06:32:56Z http://umpir.ump.edu.my/id/eprint/19848/ Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan Ngien, S. K. Yap, H. T. TA Engineering (General). Civil engineering (General) Malaysian sewerage systems are designed according to the Malaysian Standard MS 1228:1991. Manholes may be flooded and overflow if the peak flow of sewage is not properly addressed during sewerage system design. The purpose of the overall research is to analyse the per capita flow as well as design criterion in the sewerage systems within Kuantan, Pahang and compare them to their counterpart in the MS 1228:1991. This study was conducted in a residential area,Taman Pandan Damai. Population equivalent in the area was surveyed as 2244PE. ISCO 4250 Area Velocity Flowmeter was used to collect real time flowrate data using an Area Velocity Sensor. Based on the results obtained the average per capita flow and design criterion was lower than the 0.225m3/day/person and 4.7 stated in MS 1228:1991, respectively. This indicated that the design of the sewerage system in Taman Pandan Damai was more than capable of catering to the PE serviced in that area. 2017-01 Conference or Workshop Item PeerReviewed application/msword en http://umpir.ump.edu.my/id/eprint/19848/1/YapHiewThong_FluidsChE%202017%20abstract%20v1.docx application/pdf en http://umpir.ump.edu.my/id/eprint/19848/3/Flow%20Design%20of%20Sewerage%20System%20%E2%80%93%20A%20Case.pdf Ngien, S. K. and Yap, H. T. (2017) Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan. In: International Conference on Fluids and Chemical Engineering (FluidsChE2017), 4-6 April 2017 , Kota Kinabalu, Sabah. pp. 1-4., 10 (2). ISSN 0974-6846(Print); 0974-5645(Online) http://dx.doi.org/10.17485/ijst%2F2017%2Fv10i2%2F110375
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Ngien, S. K.
Yap, H. T.
Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
description Malaysian sewerage systems are designed according to the Malaysian Standard MS 1228:1991. Manholes may be flooded and overflow if the peak flow of sewage is not properly addressed during sewerage system design. The purpose of the overall research is to analyse the per capita flow as well as design criterion in the sewerage systems within Kuantan, Pahang and compare them to their counterpart in the MS 1228:1991. This study was conducted in a residential area,Taman Pandan Damai. Population equivalent in the area was surveyed as 2244PE. ISCO 4250 Area Velocity Flowmeter was used to collect real time flowrate data using an Area Velocity Sensor. Based on the results obtained the average per capita flow and design criterion was lower than the 0.225m3/day/person and 4.7 stated in MS 1228:1991, respectively. This indicated that the design of the sewerage system in Taman Pandan Damai was more than capable of catering to the PE serviced in that area.
format Conference or Workshop Item
author Ngien, S. K.
Yap, H. T.
author_facet Ngien, S. K.
Yap, H. T.
author_sort Ngien, S. K.
title Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
title_short Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
title_full Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
title_fullStr Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
title_full_unstemmed Flow design of sewerage system – a case study in Taman Pandan Damai, Kuantan
title_sort flow design of sewerage system – a case study in taman pandan damai, kuantan
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/19848/1/YapHiewThong_FluidsChE%202017%20abstract%20v1.docx
http://umpir.ump.edu.my/id/eprint/19848/3/Flow%20Design%20of%20Sewerage%20System%20%E2%80%93%20A%20Case.pdf
http://umpir.ump.edu.my/id/eprint/19848/
http://dx.doi.org/10.17485/ijst%2F2017%2Fv10i2%2F110375
_version_ 1643668744293056512
score 13.15806