Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification

The non-invasive technique is one of the favourite methods applied in process plants, compared to other sensing techniques. Due to certain advantages, this technique is also implemented in process tomography such as in non-invasive ERT systems for multiphase mixtures. The purpose of this paper is to...

Full description

Saved in:
Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Ruzairi, Abdul Rahim, Leow, Pei Ling, Mohd Hafiz, Fazalul Rahiman, Suzanna, Ridzuan Aw, Fazlul Rahman, Mohd Yunus, Herlina, Abdul Rahim
Format: Article
Language:English
Published: Elsevier 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/19741/1/fkee-2018-yasmin-Optimisation%20of%20Electrode%20Dimensions%20of%20ERT%20for%20Non-Invasive1.pdf
http://umpir.ump.edu.my/id/eprint/19741/
http://dx.doi.org/10.1016/j.sna.2017.12.017
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.19741
record_format eprints
spelling my.ump.umpir.197412018-10-09T07:30:57Z http://umpir.ump.edu.my/id/eprint/19741/ Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Leow, Pei Ling Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Herlina, Abdul Rahim TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering The non-invasive technique is one of the favourite methods applied in process plants, compared to other sensing techniques. Due to certain advantages, this technique is also implemented in process tomography such as in non-invasive ERT systems for multiphase mixtures. The purpose of this paper is to investigate the optimum size of the area of the electrode in terms of the width and height for the non-invasive ERT system that can be applied for a static liquid-gas regime. Based on a quasi-static electric field, a 2D simulation using finite element model software (COMSOL Multiphysics) was used to analyse the simulation results. As a result, by applying several widths and heights to the system, 18.5º and 200 mm in width and height, respectively, were chosen as the optimum dimensions to be applied for a 100 mm outer diameter and 2 mm thick acrylic pipe for the non-invasive ERT electrode. Later, experiments were conducted to obtain the tomogram for image verification. Thus, it is believed that the implementation of the optimised area of the electrode can allow the electricity to be emitted and significantly detected. The non-invasive ERT system will also give an alternative way for industry to monitor the performance of process plants. Elsevier 2018-02-01 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/19741/1/fkee-2018-yasmin-Optimisation%20of%20Electrode%20Dimensions%20of%20ERT%20for%20Non-Invasive1.pdf Yasmin, Abdul Wahab and Ruzairi, Abdul Rahim and Leow, Pei Ling and Mohd Hafiz, Fazalul Rahiman and Suzanna, Ridzuan Aw and Fazlul Rahman, Mohd Yunus and Herlina, Abdul Rahim (2018) Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification. Sensors and Actuators: A Physical, 270. pp. 50-64. ISSN 0924-4247 http://dx.doi.org/10.1016/j.sna.2017.12.017 10.1016/j.sna.2017.12.017
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Leow, Pei Ling
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
description The non-invasive technique is one of the favourite methods applied in process plants, compared to other sensing techniques. Due to certain advantages, this technique is also implemented in process tomography such as in non-invasive ERT systems for multiphase mixtures. The purpose of this paper is to investigate the optimum size of the area of the electrode in terms of the width and height for the non-invasive ERT system that can be applied for a static liquid-gas regime. Based on a quasi-static electric field, a 2D simulation using finite element model software (COMSOL Multiphysics) was used to analyse the simulation results. As a result, by applying several widths and heights to the system, 18.5º and 200 mm in width and height, respectively, were chosen as the optimum dimensions to be applied for a 100 mm outer diameter and 2 mm thick acrylic pipe for the non-invasive ERT electrode. Later, experiments were conducted to obtain the tomogram for image verification. Thus, it is believed that the implementation of the optimised area of the electrode can allow the electricity to be emitted and significantly detected. The non-invasive ERT system will also give an alternative way for industry to monitor the performance of process plants.
format Article
author Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Leow, Pei Ling
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
author_facet Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Leow, Pei Ling
Mohd Hafiz, Fazalul Rahiman
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
author_sort Yasmin, Abdul Wahab
title Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
title_short Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
title_full Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
title_fullStr Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
title_full_unstemmed Optimisation of Electrode Dimensions of ERT for Non-Invasive Measurement Applied for Static Liquid-Gas Regime Identification
title_sort optimisation of electrode dimensions of ert for non-invasive measurement applied for static liquid-gas regime identification
publisher Elsevier
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/19741/1/fkee-2018-yasmin-Optimisation%20of%20Electrode%20Dimensions%20of%20ERT%20for%20Non-Invasive1.pdf
http://umpir.ump.edu.my/id/eprint/19741/
http://dx.doi.org/10.1016/j.sna.2017.12.017
_version_ 1643668723620380672
score 13.159267