The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function

Pressure transient signal occurred due to sudden changes in fluid propagation filled in pipelines system, which is caused by rapid pressure and flow fluctuation in a system, such as closing and opening valve rapidly. The application of Hilbert-Huang Transform (HHT) as the method to analyse the press...

Full description

Saved in:
Bibliographic Details
Main Authors: Hanafi, M. Yusop, M. F., Ghazali, M. F. M., Yusof, Remli, M. A. Pi, Karollah, B., Rusman, .
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/19034/1/fkm-2017-hanafi-The%20use%20of%20transmission%20line%20modelling%20to%20test%20the%20effectiveness.pdf
http://umpir.ump.edu.my/id/eprint/19034/
https://doi.org/10.1088/1757-899X/257/1/012070
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.19034
record_format eprints
spelling my.ump.umpir.190342017-11-13T04:37:17Z http://umpir.ump.edu.my/id/eprint/19034/ The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function Hanafi, M. Yusop M. F., Ghazali M. F. M., Yusof Remli, M. A. Pi Karollah, B. Rusman, . TJ Mechanical engineering and machinery Pressure transient signal occurred due to sudden changes in fluid propagation filled in pipelines system, which is caused by rapid pressure and flow fluctuation in a system, such as closing and opening valve rapidly. The application of Hilbert-Huang Transform (HHT) as the method to analyse the pressure transient signal utilised in this research. However, this method has the difficulty in selecting the suitable IMF for the further post-processing, which is Hilbert Transform (HT). This paper proposed the implementation of Integrated Kurtosis-based Algorithm for z-filter Technique (I-kaz) to kurtosis ratio (I-kaz-Kurtosis) for that allows automatic selection of intrinsic mode function (IMF) that's should be used. This work demonstrated the synthetic pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of I-kaz as the autonomous selection of intrinsic mode function (IMF). A straight fluid network was designed using TLM fixing with higher resistance at some point act as a leak and connecting to the pipe feature (junction, pipefitting or blockage). The analysis results using I-kaz-kurtosis ratio revealed that the method can be utilised as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. I-kaz-kurtosis ratio is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through HHT analysis. IOP Publishing 2017 Conference or Workshop Item PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/19034/1/fkm-2017-hanafi-The%20use%20of%20transmission%20line%20modelling%20to%20test%20the%20effectiveness.pdf Hanafi, M. Yusop and M. F., Ghazali and M. F. M., Yusof and Remli, M. A. Pi and Karollah, B. and Rusman, . (2017) The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function. In: IOP Conference Series: Materials Science and Engineering, 4th International Conference on Mechanical Engineering Research (ICMER2017), 1-2 August 2017 , Kuantan, Pahang, Malaysia. pp. 1-10., 257 (012070). ISSN 1757-899X https://doi.org/10.1088/1757-899X/257/1/012070
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
Remli, M. A. Pi
Karollah, B.
Rusman, .
The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
description Pressure transient signal occurred due to sudden changes in fluid propagation filled in pipelines system, which is caused by rapid pressure and flow fluctuation in a system, such as closing and opening valve rapidly. The application of Hilbert-Huang Transform (HHT) as the method to analyse the pressure transient signal utilised in this research. However, this method has the difficulty in selecting the suitable IMF for the further post-processing, which is Hilbert Transform (HT). This paper proposed the implementation of Integrated Kurtosis-based Algorithm for z-filter Technique (I-kaz) to kurtosis ratio (I-kaz-Kurtosis) for that allows automatic selection of intrinsic mode function (IMF) that's should be used. This work demonstrated the synthetic pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of I-kaz as the autonomous selection of intrinsic mode function (IMF). A straight fluid network was designed using TLM fixing with higher resistance at some point act as a leak and connecting to the pipe feature (junction, pipefitting or blockage). The analysis results using I-kaz-kurtosis ratio revealed that the method can be utilised as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. I-kaz-kurtosis ratio is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through HHT analysis.
format Conference or Workshop Item
author Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
Remli, M. A. Pi
Karollah, B.
Rusman, .
author_facet Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
Remli, M. A. Pi
Karollah, B.
Rusman, .
author_sort Hanafi, M. Yusop
title The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
title_short The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
title_full The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
title_fullStr The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
title_full_unstemmed The Use of Transmission Line Modelling to Test the Effectiveness of I-kaz as Autonomous Selection of Intrinsic Mode Function
title_sort use of transmission line modelling to test the effectiveness of i-kaz as autonomous selection of intrinsic mode function
publisher IOP Publishing
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/19034/1/fkm-2017-hanafi-The%20use%20of%20transmission%20line%20modelling%20to%20test%20the%20effectiveness.pdf
http://umpir.ump.edu.my/id/eprint/19034/
https://doi.org/10.1088/1757-899X/257/1/012070
_version_ 1643668588247121920
score 13.211869