Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase
A full factorial design (FFD) approach was conducted to assess the effect of four factors, namely flow rate, duty cycle, amplitude, and treatment time of ultrasonic regimens towards Escherichia coli harbouring lipase. The 22 experiments were performed as the following values with six replicates of c...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IOP Publishing
2017
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/18355/1/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase.pdf http://umpir.ump.edu.my/id/eprint/18355/2/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase%201.pdf http://umpir.ump.edu.my/id/eprint/18355/ http://iopscience.iop.org/article/10.1088/1757-899X/206/1/012021/pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.18355 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.183552018-01-23T03:41:57Z http://umpir.ump.edu.my/id/eprint/18355/ Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase W. S. A., W. Omar Ahmad Ziad, Sulaiman Azilah, Ajit Y., Chisti A. L. T. , Chor TP Chemical technology A full factorial design (FFD) approach was conducted to assess the effect of four factors, namely flow rate, duty cycle, amplitude, and treatment time of ultrasonic regimens towards Escherichia coli harbouring lipase. The 22 experiments were performed as the following values with six replicates of centre point: flow rate (0.1, 0.2, and 0.3 L/min), duty cycle (0, 20, and 40 ), amplitude (2, 6, and 10), and treatment time (10, 35, and 60 min). The FFD was employed as preliminary screening in shake flask cultivation to choose the significant factors (P< 0.05) for further optimisation process. In this study, zero duty cycle signified non-sonication of amplitude and no treatment time effect to the E. coli culture. Also, the designated flow rate and amplitude accordingly showed no effect towards the amount of dry cells weight (DCW). DCW1 was found significantly degraded after the exposure of high duty cycle and treatment time as other factors remained constant. Whereas for the lipase activity, no significant difference was observed in any main factors or interactions. Paired samples t-test confirms the result at a p-value of 0.625. This experimental study suggests the direct and continuous approach of sonication caused an adverse effect on the cells culture density. IOP Publishing 2017-06 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/18355/1/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/18355/2/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase%201.pdf W. S. A., W. Omar and Ahmad Ziad, Sulaiman and Azilah, Ajit and Y., Chisti and A. L. T. , Chor (2017) Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase. In: 29th Symposium of Malaysian Chemical Engineers (SOMChE) 2016, 1–3 December 2016 , Miri, Sarawak, Malaysia. pp. 1-11., 206 (1). ISSN 1757-8981 (Print); 1757-899X (Online) http://iopscience.iop.org/article/10.1088/1757-899X/206/1/012021/pdf DOI: 10.1088/1757-899X/206/1/012021 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology W. S. A., W. Omar Ahmad Ziad, Sulaiman Azilah, Ajit Y., Chisti A. L. T. , Chor Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
description |
A full factorial design (FFD) approach was conducted to assess the effect of four factors, namely flow rate, duty cycle, amplitude, and treatment time of ultrasonic regimens towards Escherichia coli harbouring lipase. The 22 experiments were performed as the following values with six replicates of centre point: flow rate (0.1, 0.2, and 0.3 L/min), duty cycle (0, 20, and 40 ), amplitude (2, 6, and 10), and treatment time (10, 35, and 60 min). The FFD was employed as preliminary screening in shake flask cultivation to choose the significant factors (P< 0.05) for further optimisation process. In this study, zero duty cycle signified non-sonication of amplitude and no treatment time effect to the E. coli culture. Also, the designated flow rate and amplitude accordingly showed no effect towards the amount of dry cells weight (DCW). DCW1 was found significantly degraded after the exposure of high duty cycle and treatment time as other factors remained constant. Whereas for the lipase activity, no significant difference was observed in any main factors or interactions. Paired samples t-test confirms the result at a p-value of 0.625. This experimental study suggests the direct and continuous approach of sonication caused an adverse effect on the cells culture density. |
format |
Conference or Workshop Item |
author |
W. S. A., W. Omar Ahmad Ziad, Sulaiman Azilah, Ajit Y., Chisti A. L. T. , Chor |
author_facet |
W. S. A., W. Omar Ahmad Ziad, Sulaiman Azilah, Ajit Y., Chisti A. L. T. , Chor |
author_sort |
W. S. A., W. Omar |
title |
Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
title_short |
Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
title_full |
Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
title_fullStr |
Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
title_full_unstemmed |
Effect of Flow Rate, Duty Cycle, Amplitude, and Treatment Time of Ultrasonic Regimens Towards Escherichia Coli Harbouring Lipase |
title_sort |
effect of flow rate, duty cycle, amplitude, and treatment time of ultrasonic regimens towards escherichia coli harbouring lipase |
publisher |
IOP Publishing |
publishDate |
2017 |
url |
http://umpir.ump.edu.my/id/eprint/18355/1/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase.pdf http://umpir.ump.edu.my/id/eprint/18355/2/Effect%20of%20flow%20rate%2C%20duty%20cycle%2C%20amplitude%2C%20and%20treatment%20Time%20of%20ultrasonic%20regimens%20towards%20Escherichia%20coli%20harbouring%20lipase%201.pdf http://umpir.ump.edu.my/id/eprint/18355/ http://iopscience.iop.org/article/10.1088/1757-899X/206/1/012021/pdf |
_version_ |
1643668424752103424 |
score |
13.211869 |