Investigation on impact hammer testing with different types of hammer tip for welded thin plate

Modal testing using impact hammer had been used extensively in various industries to analyze the dynamic properties of the structure. Impact testing become famous due to their advantages for instances; fast, compatible for measurements in the field and relatively inexpensive. Even though these metho...

Full description

Saved in:
Bibliographic Details
Main Authors: Siti Norazila, Zahari, M. S. M., Sani
Format: Article
Language:English
English
Published: American Scientific Publisher 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/17074/1/Investigation%20on%20Impact%20Hammer%20Testing%20with.pdf
http://umpir.ump.edu.my/id/eprint/17074/7/fkm-2016-sani-%20Hammer%20Testing%20with%20Different%20Types%20of%20Hammer%20Tip.pdf
http://umpir.ump.edu.my/id/eprint/17074/
https://doi.org/10.1166/asl.2017.10276
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.17074
record_format eprints
spelling my.ump.umpir.170742018-08-29T02:40:48Z http://umpir.ump.edu.my/id/eprint/17074/ Investigation on impact hammer testing with different types of hammer tip for welded thin plate Siti Norazila, Zahari M. S. M., Sani TJ Mechanical engineering and machinery Modal testing using impact hammer had been used extensively in various industries to analyze the dynamic properties of the structure. Impact testing become famous due to their advantages for instances; fast, compatible for measurements in the field and relatively inexpensive. Even though these methods are fast and convenient, many important consideration should be take note during the measurement in order to get an accurate result. For this paper, hammer tip selection become the research issue. The thin sheet plate with different materials (Aluminum alloy; AA7075 & AA6061) joined by friction stir welding (FSW) will be used as a specimen. Four types of hammer tip used in this study; hard, medium, soft and super soft tip. The effect of hammer tip towards the shape of coherence and frequency response function for ranging between 0 to 1000 Hz will be discussed further. From this experiment, it was found that medium tip chosen as the most compatible tip for thin plate joined by FSW. American Scientific Publisher 2017-11 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/17074/1/Investigation%20on%20Impact%20Hammer%20Testing%20with.pdf pdf en http://umpir.ump.edu.my/id/eprint/17074/7/fkm-2016-sani-%20Hammer%20Testing%20with%20Different%20Types%20of%20Hammer%20Tip.pdf Siti Norazila, Zahari and M. S. M., Sani (2017) Investigation on impact hammer testing with different types of hammer tip for welded thin plate. Advanced Science Letters, 23 (11). pp. 11325-11329. ISSN 1936-6612 https://doi.org/10.1166/asl.2017.10276 10.1166/asl.2017.10276
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Siti Norazila, Zahari
M. S. M., Sani
Investigation on impact hammer testing with different types of hammer tip for welded thin plate
description Modal testing using impact hammer had been used extensively in various industries to analyze the dynamic properties of the structure. Impact testing become famous due to their advantages for instances; fast, compatible for measurements in the field and relatively inexpensive. Even though these methods are fast and convenient, many important consideration should be take note during the measurement in order to get an accurate result. For this paper, hammer tip selection become the research issue. The thin sheet plate with different materials (Aluminum alloy; AA7075 & AA6061) joined by friction stir welding (FSW) will be used as a specimen. Four types of hammer tip used in this study; hard, medium, soft and super soft tip. The effect of hammer tip towards the shape of coherence and frequency response function for ranging between 0 to 1000 Hz will be discussed further. From this experiment, it was found that medium tip chosen as the most compatible tip for thin plate joined by FSW.
format Article
author Siti Norazila, Zahari
M. S. M., Sani
author_facet Siti Norazila, Zahari
M. S. M., Sani
author_sort Siti Norazila, Zahari
title Investigation on impact hammer testing with different types of hammer tip for welded thin plate
title_short Investigation on impact hammer testing with different types of hammer tip for welded thin plate
title_full Investigation on impact hammer testing with different types of hammer tip for welded thin plate
title_fullStr Investigation on impact hammer testing with different types of hammer tip for welded thin plate
title_full_unstemmed Investigation on impact hammer testing with different types of hammer tip for welded thin plate
title_sort investigation on impact hammer testing with different types of hammer tip for welded thin plate
publisher American Scientific Publisher
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/17074/1/Investigation%20on%20Impact%20Hammer%20Testing%20with.pdf
http://umpir.ump.edu.my/id/eprint/17074/7/fkm-2016-sani-%20Hammer%20Testing%20with%20Different%20Types%20of%20Hammer%20Tip.pdf
http://umpir.ump.edu.my/id/eprint/17074/
https://doi.org/10.1166/asl.2017.10276
_version_ 1643668083049496576
score 13.214268