Development of DEM-CFD Simulation of Combustion Flow in Incinerator with the Representative Particle Model

A simulation code based on the discrete element method (DEM) and computational fluid dynamics (CFD) coupling model was developed to simulate the behavior of radioactive cesium in waste incinerators. The waste lump was represented by particles in the simulation. The energy equation for a mixed gas, d...

Full description

Saved in:
Bibliographic Details
Main Authors: Kuwagi, Kenya, Takami, Toshihiro, Azri, Alias, Rong, Degang, Takeda, Hiroshi, Yanase, Shinichiro, Kouchi, Toshinori, Hyakutake, Toru, Yokoyama, Kaoru, Ohara, Yoshiyuki, Takahashi, Nobuo, Sugitsue, Noritake
Format: Article
Language:English
Published: The Society of Chemical Engineers, Japan 2016
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/15242/1/Development%20of%20DEM%E2%80%93CFD%20Simulation%20of%20Combustion%20Flow-fkm-2016-1.pdf
http://umpir.ump.edu.my/id/eprint/15242/
http://doi.org/10.1252/jcej.15we099
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simulation code based on the discrete element method (DEM) and computational fluid dynamics (CFD) coupling model was developed to simulate the behavior of radioactive cesium in waste incinerators. The waste lump was represented by particles in the simulation. The energy equation for a mixed gas, diffusion equation for each gas component, as well as the energy, drying, pyrolysis, and combustion equations for each particle were solved in the simulation by adding a combustion model to the standard DEM–CFD coupling model. The particle size of the waste changed as drying, pyrolysis, and combustion progressed. At the end of the combustion process, particle waste became ash, and the number of ash particles was enormous. To avoid an excessive computational load due to the high particle number, a similar assembly model was adopted to reduce the particle number in the calculation. There was a good agreement between the simulation and experimental results for the temperature at the outlet of the furnace and the flue gas composition.