Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate

Optical fiber systems for dynamic response measurement become an attractive study nowadays especially in the field of Structural Health Monitoring (SHM). This work presents the investigation of an optical fiber sensor system utilizing Near Infra-Red Fiber Bragg Grating (NIR-FBG) sensor for SHM of a...

Full description

Saved in:
Bibliographic Details
Main Authors: Z. M., Hafizi, J. A., Epaarachchi
Format: Conference or Workshop Item
Language:English
Published: 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/11862/1/Dynamic%20Response%20and%20Signal%20to%20Noise%20Ratio%20Investigation%20of%20NIR-FBG%20Dynamic%20Sensing%20System%20for%20Monitoring%20Thinwalled%20Composite%20Plate.pdf
http://umpir.ump.edu.my/id/eprint/11862/
http://iopscience.iop.org/article/10.1088/1757-899X/100/1/012056/meta
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.11862
record_format eprints
spelling my.ump.umpir.118622016-05-10T01:50:11Z http://umpir.ump.edu.my/id/eprint/11862/ Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate Z. M., Hafizi J. A., Epaarachchi TJ Mechanical engineering and machinery Optical fiber systems for dynamic response measurement become an attractive study nowadays especially in the field of Structural Health Monitoring (SHM). This work presents the investigation of an optical fiber sensor system utilizing Near Infra-Red Fiber Bragg Grating (NIR-FBG) sensor for SHM of a thin-walled composite structure. In this study, a comparison between the experimental result and simulation study using finite element analysis has been presented. By comparing both results, the FBG dynamic sensing system was shown to have an excellent capability in acquiring dynamic response due to flexural wave propagations. In the meantime, a signal to noise ratio (SNR) study was also performed to several FBG dynamic sensor systems; particularly to see the comparison between NIR-FBG sensor and 1550 nm FBG sensor. Furthermore, with a proper configuration, an NIR-FBG system was proved to have better performance than the 1550 nm based FBG sensor. 2015 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/11862/1/Dynamic%20Response%20and%20Signal%20to%20Noise%20Ratio%20Investigation%20of%20NIR-FBG%20Dynamic%20Sensing%20System%20for%20Monitoring%20Thinwalled%20Composite%20Plate.pdf Z. M., Hafizi and J. A., Epaarachchi (2015) Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate. In: 3rd International Conference on Mechanical Engineering Research (ICMER 2015), 18-19 August 2015 , Kuantan, Pahang. pp. 1-10.. http://iopscience.iop.org/article/10.1088/1757-899X/100/1/012056/meta
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Z. M., Hafizi
J. A., Epaarachchi
Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
description Optical fiber systems for dynamic response measurement become an attractive study nowadays especially in the field of Structural Health Monitoring (SHM). This work presents the investigation of an optical fiber sensor system utilizing Near Infra-Red Fiber Bragg Grating (NIR-FBG) sensor for SHM of a thin-walled composite structure. In this study, a comparison between the experimental result and simulation study using finite element analysis has been presented. By comparing both results, the FBG dynamic sensing system was shown to have an excellent capability in acquiring dynamic response due to flexural wave propagations. In the meantime, a signal to noise ratio (SNR) study was also performed to several FBG dynamic sensor systems; particularly to see the comparison between NIR-FBG sensor and 1550 nm FBG sensor. Furthermore, with a proper configuration, an NIR-FBG system was proved to have better performance than the 1550 nm based FBG sensor.
format Conference or Workshop Item
author Z. M., Hafizi
J. A., Epaarachchi
author_facet Z. M., Hafizi
J. A., Epaarachchi
author_sort Z. M., Hafizi
title Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
title_short Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
title_full Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
title_fullStr Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
title_full_unstemmed Dynamic Response and Signal to Noise Ratio Investigation of NIR-FBG Dynamic Sensing System for Monitoring Thinwalled Composite Plate
title_sort dynamic response and signal to noise ratio investigation of nir-fbg dynamic sensing system for monitoring thinwalled composite plate
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/11862/1/Dynamic%20Response%20and%20Signal%20to%20Noise%20Ratio%20Investigation%20of%20NIR-FBG%20Dynamic%20Sensing%20System%20for%20Monitoring%20Thinwalled%20Composite%20Plate.pdf
http://umpir.ump.edu.my/id/eprint/11862/
http://iopscience.iop.org/article/10.1088/1757-899X/100/1/012056/meta
_version_ 1643666756393238528
score 13.211869