Corrosion protection of steel structure for industrial application

The present paper discusses the study of effect of corrosion protection on steel structure, effect of PH medium on steel structure and effect of deformation on corrosion rate in order to find the best solution for the corrosion problem. The objective of this is to experiment and analyze the corrosio...

Full description

Saved in:
Bibliographic Details
Main Author: Asmerol, Alias
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1042/17/05.Corrosion%20protection%20of%20steel%20structure%20for%20industrial%20application.pdf
http://umpir.ump.edu.my/id/eprint/1042/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.1042
record_format eprints
spelling my.ump.umpir.10422023-09-06T02:50:23Z http://umpir.ump.edu.my/id/eprint/1042/ Corrosion protection of steel structure for industrial application Asmerol, Alias TA Engineering (General). Civil engineering (General) The present paper discusses the study of effect of corrosion protection on steel structure, effect of PH medium on steel structure and effect of deformation on corrosion rate in order to find the best solution for the corrosion problem. The objective of this is to experiment and analyze the corrosion behaviour of steel structure, to investigate the effect of corrosion protection for industrial application and to analyze the effectiveness of corrosion protections in various medium. The thesis use mild steel as the specimen and 3 medium as for the type of environment which is acid, air and alkali. The thesis presents the effectiveness of protection between cathodic protections, coating and controlled specimen as default data. The sample preparation based on ASTM guide which involving specimen cutting, specimen deformation and specimen cleaning. Specimen deformation is the step where the specimen is bended 90° at the centre of specimen. The experiment is steps where the protection applied to specimen and expose to mediums for 28 days. The analysis step start from surface analysis using SEM to specimen cleaning using reagent and weight losses measurement at the end. From the result, it is observed that cathodic protection has the lowest corrosion rate compare to coating although there’s no big differences between them and acid medium has the recorded the highest corrosion rate while alkali medium recorded the lowest corrosion rate. The obtained result indicate that acidic medium tend to increase the corrosion rate while alkaline medium tend to decrease the corrosion rate. Although cathodic protection has the best result but the coating protection chosen the best protection due the limitation that cathodic protection can be applied. Nevertheless there are some recommendation to improve the quality of protection and its environment thus corrosion reaction can be avoided. 2009-11 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/1042/17/05.Corrosion%20protection%20of%20steel%20structure%20for%20industrial%20application.pdf Asmerol, Alias (2009) Corrosion protection of steel structure for industrial application. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Asmerol, Alias
Corrosion protection of steel structure for industrial application
description The present paper discusses the study of effect of corrosion protection on steel structure, effect of PH medium on steel structure and effect of deformation on corrosion rate in order to find the best solution for the corrosion problem. The objective of this is to experiment and analyze the corrosion behaviour of steel structure, to investigate the effect of corrosion protection for industrial application and to analyze the effectiveness of corrosion protections in various medium. The thesis use mild steel as the specimen and 3 medium as for the type of environment which is acid, air and alkali. The thesis presents the effectiveness of protection between cathodic protections, coating and controlled specimen as default data. The sample preparation based on ASTM guide which involving specimen cutting, specimen deformation and specimen cleaning. Specimen deformation is the step where the specimen is bended 90° at the centre of specimen. The experiment is steps where the protection applied to specimen and expose to mediums for 28 days. The analysis step start from surface analysis using SEM to specimen cleaning using reagent and weight losses measurement at the end. From the result, it is observed that cathodic protection has the lowest corrosion rate compare to coating although there’s no big differences between them and acid medium has the recorded the highest corrosion rate while alkali medium recorded the lowest corrosion rate. The obtained result indicate that acidic medium tend to increase the corrosion rate while alkaline medium tend to decrease the corrosion rate. Although cathodic protection has the best result but the coating protection chosen the best protection due the limitation that cathodic protection can be applied. Nevertheless there are some recommendation to improve the quality of protection and its environment thus corrosion reaction can be avoided.
format Undergraduates Project Papers
author Asmerol, Alias
author_facet Asmerol, Alias
author_sort Asmerol, Alias
title Corrosion protection of steel structure for industrial application
title_short Corrosion protection of steel structure for industrial application
title_full Corrosion protection of steel structure for industrial application
title_fullStr Corrosion protection of steel structure for industrial application
title_full_unstemmed Corrosion protection of steel structure for industrial application
title_sort corrosion protection of steel structure for industrial application
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/1042/17/05.Corrosion%20protection%20of%20steel%20structure%20for%20industrial%20application.pdf
http://umpir.ump.edu.my/id/eprint/1042/
_version_ 1778161028953014272
score 13.211869