Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing
Demand of safe and and clean drinking water are increasing every day, especially in developing country such as Malaysia. High population will increase water demand proportionally but the supply of water is still low. Due to this concern, riverbank filtration system was implemented as an alternati...
Saved in:
Main Author: | |
---|---|
Format: | Undergraduates Project Papers |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/10086/1/NURHAZIRAH%20BINTI%20ABDUL%20MALIK%20%23.PDF http://umpir.ump.edu.my/id/eprint/10086/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.10086 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.100862021-07-21T03:15:55Z http://umpir.ump.edu.my/id/eprint/10086/ Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing Nurhazirah, Abdul Malik TA Engineering (General). Civil engineering (General) Demand of safe and and clean drinking water are increasing every day, especially in developing country such as Malaysia. High population will increase water demand proportionally but the supply of water is still low. Due to this concern, riverbank filtration system was implemented as an alternative to produce safe and clean drinking water in a faster and economical way. Common conventional water treatment process involve coagulation, flocculation, sedimentation, filtration and disinfection. Unlike conventional water treatment, riverbank filtration system in this study use riverbank soil modified with activated carbon (AC). Activated carbon is used as a medium of adsorption to remove all the organic contaminants found in water. Four parameters of water are taken into consideration in this study which are electrical conductivity, salinity, total dissolved solid and total hardness. These parameters will indicates the class of water. Sungai Belat water fall into the class II, which need further treatment for drinking water. Soil characteristic were also investigated to determine the type of soil of the riverbank in the area. The particle size distribution (sieve analysis and hydometer), Atterberg limit (liquid limit and plastic limit) and specific gravity were measured. Based on these test, the soil have 94 % of sand and 6 % clay. Adsorption test was conducted between different masses of soil and water using TDS as an indicator. The optimum time and mass (15 min with 2 g soil) was used in the adsorption test. This test will determine the most suitable ratio used for the filtration. 20:80 ratio was found to be the best ratio. Based on the filtration test, the filtration using natural soil with activated carbon was better than natural soil only. Three parameters which were electical conductivity, total dissolved soliad and hardness show decresing in value meanwhile salinity decreased. Further treatment should be carried out to achieve INWQS standard. 2014-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/10086/1/NURHAZIRAH%20BINTI%20ABDUL%20MALIK%20%23.PDF Nurhazirah, Abdul Malik (2014) Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang . |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Nurhazirah, Abdul Malik Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
description |
Demand of safe and and clean drinking water are increasing every day, especially in
developing country such as Malaysia. High population will increase water demand
proportionally but the supply of water is still low. Due to this concern, riverbank
filtration system was implemented as an alternative to produce safe and clean drinking
water in a faster and economical way. Common conventional water treatment process
involve coagulation, flocculation, sedimentation, filtration and disinfection. Unlike
conventional water treatment, riverbank filtration system in this study use riverbank soil
modified with activated carbon (AC). Activated carbon is used as a medium of
adsorption to remove all the organic contaminants found in water. Four parameters of
water are taken into consideration in this study which are electrical conductivity,
salinity, total dissolved solid and total hardness. These parameters will indicates the
class of water. Sungai Belat water fall into the class II, which need further treatment for
drinking water. Soil characteristic were also investigated to determine the type of soil of
the riverbank in the area. The particle size distribution (sieve analysis and hydometer),
Atterberg limit (liquid limit and plastic limit) and specific gravity were measured. Based
on these test, the soil have 94 % of sand and 6 % clay. Adsorption test was conducted
between different masses of soil and water using TDS as an indicator. The optimum
time and mass (15 min with 2 g soil) was used in the adsorption test. This test will
determine the most suitable ratio used for the filtration. 20:80 ratio was found to be the
best ratio. Based on the filtration test, the filtration using natural soil with activated
carbon was better than natural soil only. Three parameters which were electical
conductivity, total dissolved soliad and hardness show decresing in value meanwhile
salinity decreased. Further treatment should be carried out to achieve INWQS standard. |
format |
Undergraduates Project Papers |
author |
Nurhazirah, Abdul Malik |
author_facet |
Nurhazirah, Abdul Malik |
author_sort |
Nurhazirah, Abdul Malik |
title |
Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
title_short |
Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
title_full |
Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
title_fullStr |
Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
title_full_unstemmed |
Applicability of riverbank filtration system in removing electrical contaminants from Sungai Belat using activated carbon: a laboratory testing |
title_sort |
applicability of riverbank filtration system in removing electrical contaminants from sungai belat using activated carbon: a laboratory testing |
publishDate |
2014 |
url |
http://umpir.ump.edu.my/id/eprint/10086/1/NURHAZIRAH%20BINTI%20ABDUL%20MALIK%20%23.PDF http://umpir.ump.edu.my/id/eprint/10086/ |
_version_ |
1706957206344171520 |
score |
13.214268 |