Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng
This thesis aims to provide additional contributions to control of multiphase machine, with a focus on asymmetrical six-phase induction machine (machine with two three-phase windings spatially displaced by 30°). Using the VSD approach, the machine’s six phase variables can be transformed into six de...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Published: |
2012
|
Subjects: | |
Online Access: | http://studentsrepo.um.edu.my/6203/1/01_Front_matter_(UM).pdf http://studentsrepo.um.edu.my/6203/2/02_Thesis_main.pdf http://studentsrepo.um.edu.my/6203/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.stud.6203 |
---|---|
record_format |
eprints |
spelling |
my.um.stud.62032016-03-19T01:33:03Z Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng Che, Hang Seng Q Science (General) This thesis aims to provide additional contributions to control of multiphase machine, with a focus on asymmetrical six-phase induction machine (machine with two three-phase windings spatially displaced by 30°). Using the VSD approach, the machine’s six phase variables can be transformed into six decoupled variables, namely α-β, x-y and two zero sequence variables. For machine with distributed windings, only the α-β components provide useful electro-mechanical energy conversion, while the other components merely produce losses. The studies presented in this thesis are based on this VSD approach, and are separated into three main parts: x-y current control methods, operation with series-connected converters and post-fault control. The first part of this research work looks into the x-y current control methods of the machine using PI controllers. It was found that the x-y currents can be physically interpreted as the circulating current between the two three-phase windings. Depending on the type of asymmetry, x-y currents can appear as positive sequence component, negative sequence component or a combination of both. Hence, performance of PI controller implemented under different reference frame is compared and discussed. In this part of the study, a dead time compensator implemented using resonant controller for x-y currents is also presented. The second part of this work investigates the operation of the six-phase machine with series-connected machine-side converters. Under this topology, the two three-phase windings are supplied by two separate two-level voltage source converters (VSCs) with their dc-link cascaded in series. The series-topology elevates dc-link voltage which gives a reduction in dc-link current and cable size. However, the additional dc-link voltage balancing control is needed to ensure equal voltage sharing. __________________________________________________________________________________________________________ iv This is accomplished by controlling x-y currents, which is a new concept introduced in this work. The final part of the research work deals with post-fault control of six-phase induction machine for a single open-circuit fault. Post-fault control is based on the full order decoupling transformation, to minimise reconfiguration of the controller. Effect of the single open-circuit fault on the machine is discussed. Here, the leg-to-phase voltage relation is identified as an important issue that needs to be addressed when using PI controllers for post-fault operation. Different modes of post-fault operation are analysed and compared. The study considers both the cases where the six-phase machine is configured with single as well as with two isolated neutrals, such that a unified comparison is achieved. In conclusion, this thesis provides insights on the control of x-y currents in six-phase machine based on PI controllers in different reference frame. Two interesting uses of these currents, i.e. for dead time compensation and dc-link voltage balancing have also been presented. In terms of alternative converter topology, the operation of six-phase machine with series-connected machine-side converter is detailed, addressing the merits and demerits of the topology. Lastly, the operation of six-phase induction machine under different modes of post-fault control is studied and compared. All studies are based on simulation in Matlab/Simulink environment and are further verified on a 1.1 kW prototype asymmetrical six-phase induction machine. 2012 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/6203/1/01_Front_matter_(UM).pdf application/pdf http://studentsrepo.um.edu.my/6203/2/02_Thesis_main.pdf Che, Hang Seng (2012) Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng. PhD thesis, University of Malaya. http://studentsrepo.um.edu.my/6203/ |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Student Repository |
url_provider |
http://studentsrepo.um.edu.my/ |
topic |
Q Science (General) |
spellingShingle |
Q Science (General) Che, Hang Seng Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
description |
This thesis aims to provide additional contributions to control of multiphase machine, with a focus on asymmetrical six-phase induction machine (machine with two three-phase windings spatially displaced by 30°). Using the VSD approach, the machine’s six phase variables can be transformed into six decoupled variables, namely α-β, x-y and two zero sequence variables. For machine with distributed windings, only the α-β components provide useful electro-mechanical energy conversion, while the other components merely produce losses. The studies presented in this thesis are based on this VSD approach, and are separated into three main parts: x-y current control methods, operation with series-connected converters and post-fault control. The first part of this research work looks into the x-y current control methods of the machine using PI controllers. It was found that the x-y currents can be physically interpreted as the circulating current between the two three-phase windings. Depending on the type of asymmetry, x-y currents can appear as positive sequence component, negative sequence component or a combination of both. Hence, performance of PI controller implemented under different reference frame is compared and discussed. In this part of the study, a dead time compensator implemented using resonant controller for x-y currents is also presented. The second part of this work investigates the operation of the six-phase machine with series-connected machine-side converters. Under this topology, the two three-phase windings are supplied by two separate two-level voltage source converters (VSCs) with their dc-link cascaded in series. The series-topology elevates dc-link voltage which gives a reduction in dc-link current and cable size. However, the additional dc-link voltage balancing control is needed to ensure equal voltage sharing.
__________________________________________________________________________________________________________
iv
This is accomplished by controlling x-y currents, which is a new concept introduced in this work. The final part of the research work deals with post-fault control of six-phase induction machine for a single open-circuit fault. Post-fault control is based on the full order decoupling transformation, to minimise reconfiguration of the controller. Effect of the single open-circuit fault on the machine is discussed. Here, the leg-to-phase voltage relation is identified as an important issue that needs to be addressed when using PI controllers for post-fault operation. Different modes of post-fault operation are analysed and compared. The study considers both the cases where the six-phase machine is configured with single as well as with two isolated neutrals, such that a unified comparison is achieved. In conclusion, this thesis provides insights on the control of x-y currents in six-phase machine based on PI controllers in different reference frame. Two interesting uses of these currents, i.e. for dead time compensation and dc-link voltage balancing have also been presented. In terms of alternative converter topology, the operation of six-phase machine with series-connected machine-side converter is detailed, addressing the merits and demerits of the topology. Lastly, the operation of six-phase induction machine under different modes of post-fault control is studied and compared. All studies are based on simulation in Matlab/Simulink environment and are further verified on a 1.1 kW prototype asymmetrical six-phase induction machine. |
format |
Thesis |
author |
Che, Hang Seng |
author_facet |
Che, Hang Seng |
author_sort |
Che, Hang Seng |
title |
Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
title_short |
Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
title_full |
Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
title_fullStr |
Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
title_full_unstemmed |
Contributions to control of an asymmetrical six-phase indcution machine / Che Hang Seng |
title_sort |
contributions to control of an asymmetrical six-phase indcution machine / che hang seng |
publishDate |
2012 |
url |
http://studentsrepo.um.edu.my/6203/1/01_Front_matter_(UM).pdf http://studentsrepo.um.edu.my/6203/2/02_Thesis_main.pdf http://studentsrepo.um.edu.my/6203/ |
_version_ |
1738505886593187840 |
score |
13.211869 |