Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman

The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Taufiq, Azman
Format: Thesis
Published: 2018
Subjects:
Online Access:http://studentsrepo.um.edu.my/11570/4/taufiq.pdf
http://studentsrepo.um.edu.my/11570/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.stud.11570
record_format eprints
spelling my.um.stud.115702020-08-25T18:57:57Z Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman Muhammad Taufiq, Azman R Medicine (General) The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as “face-up” versus “face-down” scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for “face-up” versus “facedown” orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy 2018 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/11570/4/taufiq.pdf Muhammad Taufiq, Azman (2018) Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/11570/
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Student Repository
url_provider http://studentsrepo.um.edu.my/
topic R Medicine (General)
spellingShingle R Medicine (General)
Muhammad Taufiq, Azman
Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
description The purpose of this study was to characterize specific dosimetric properties of Gafchromic HD-V2 film and to investigate its feasibility in the dosimetric verification for Stereotactic Radiosurgery (SRS). Basic dosimeter properties including energy and dose rate dependencies were investigated and HD-V2 film showed energy and dose rate dependencies of less than 9.5% and 4.94% respectively. The HD-V2 film has very low dependency on scanning orientation in portrait versus landscape as well as “face-up” versus “face-down” scanning orientation. The percentage differences recorded were less than 2.7% for portrait versus landscape and less than 2.5% for “face-up” versus “facedown” orientation. In terms of angular dependency, there was no significant influence on net optical density, with deviations less than 4.3% for films irradiated at selected gantry angles ranging from 0° (which film is perpendicular to the irradiation beam) to 180°. Two treatment plans using SRS technique were created and irradiated using HD-V2 film for dosimetric verification. The dose distributions were calculated using a treatment planning system to obtain point doses at specified positions within a phantom. The calculated doses from TPS were compared to dose distributions delivered to HD-V2 film. The results of the point dose measurements for SRS treatment irradiations showed that the deviations between the TPS predicted dose and HD-V2 film measurements were less 4% which were within the recommended values by ICRU. This study shows that Gafchromic HD-V2 film can be used as dosimetric verification for SRS and for radiotherapy clinical practices that involves high range of doses of 10 to 1000 Gy
format Thesis
author Muhammad Taufiq, Azman
author_facet Muhammad Taufiq, Azman
author_sort Muhammad Taufiq, Azman
title Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_short Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_full Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_fullStr Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_full_unstemmed Characterization of Gafchromic HD-V2 Film for dose verification in stereotactic radiosurgery (SRS) / Muhammad Taufiq Azman
title_sort characterization of gafchromic hd-v2 film for dose verification in stereotactic radiosurgery (srs) / muhammad taufiq azman
publishDate 2018
url http://studentsrepo.um.edu.my/11570/4/taufiq.pdf
http://studentsrepo.um.edu.my/11570/
_version_ 1738506500343595008
score 13.160551