Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi

Video images have been widely used to extract relevant information for applications. One such application is the heart rate estimation using facial images from video sequences. A method using Canonical Component Analysis (CCA) is introduced to estimate the heart rate reading. In this study, two five...

Full description

Saved in:
Bibliographic Details
Main Author: Ling, Siong Shi
Format: Thesis
Published: 2019
Subjects:
Online Access:http://studentsrepo.um.edu.my/11398/1/Ling_Siong_Shi.jpg
http://studentsrepo.um.edu.my/11398/8/siong_shi.pdf
http://studentsrepo.um.edu.my/11398/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.stud.11398
record_format eprints
spelling my.um.stud.113982020-07-13T23:52:37Z Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi Ling, Siong Shi TK Electrical engineering. Electronics Nuclear engineering Video images have been widely used to extract relevant information for applications. One such application is the heart rate estimation using facial images from video sequences. A method using Canonical Component Analysis (CCA) is introduced to estimate the heart rate reading. In this study, two five-second video is used. The starting points of the two 5-second video frames are not the same. One of them starts one second later. It is assumed that these two 5-second video frames will contain the heart rate signals that are strongly correlated to each other and the random artifacts and noises appearing in both video frames are not correlated to each other. Therefore the desired heart rate will remain unchanged which have the ability to give maximum correlation values. The obtained eigenvalues and eigenvectors with maximum correlation values now can be used to find the desired original sources. By examining the most correlated signal within these two video frames using Canonical Component Analysis (CCA), the heart rate can be estimated. The identified heart signal from the result of CCA is then passed to a bandpass filter (0.8-4Hz) followed by Fast Fourier Transform to obtain the heart rate. Two experiments which involve increasing and decreasing dynamic heart rate were conducted. For both experiments, eight subjects took part in a cycling activity and their heart rates varied from 70 to 157 beats per minute (BPM). The results from both methods showed that acceptable average error rates of less than 3.70 BPM are observed between the actual and the estimated heart rates. In addition to that, a study was carried out to determine the minimum distance between the subject and video camera with fixed video duration. The results from this experiment showed acceptable error rates are observed when the distance between them is less than 130cm. In the last experiment, the effects of varying video duration but with fixed distance are carried out. Acceptable error rates are observed between the actual and estimated video duration greater than 6 seconds. 2019-09 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/11398/1/Ling_Siong_Shi.jpg application/pdf http://studentsrepo.um.edu.my/11398/8/siong_shi.pdf Ling, Siong Shi (2019) Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi. Masters thesis, University Malaya. http://studentsrepo.um.edu.my/11398/
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Student Repository
url_provider http://studentsrepo.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ling, Siong Shi
Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
description Video images have been widely used to extract relevant information for applications. One such application is the heart rate estimation using facial images from video sequences. A method using Canonical Component Analysis (CCA) is introduced to estimate the heart rate reading. In this study, two five-second video is used. The starting points of the two 5-second video frames are not the same. One of them starts one second later. It is assumed that these two 5-second video frames will contain the heart rate signals that are strongly correlated to each other and the random artifacts and noises appearing in both video frames are not correlated to each other. Therefore the desired heart rate will remain unchanged which have the ability to give maximum correlation values. The obtained eigenvalues and eigenvectors with maximum correlation values now can be used to find the desired original sources. By examining the most correlated signal within these two video frames using Canonical Component Analysis (CCA), the heart rate can be estimated. The identified heart signal from the result of CCA is then passed to a bandpass filter (0.8-4Hz) followed by Fast Fourier Transform to obtain the heart rate. Two experiments which involve increasing and decreasing dynamic heart rate were conducted. For both experiments, eight subjects took part in a cycling activity and their heart rates varied from 70 to 157 beats per minute (BPM). The results from both methods showed that acceptable average error rates of less than 3.70 BPM are observed between the actual and the estimated heart rates. In addition to that, a study was carried out to determine the minimum distance between the subject and video camera with fixed video duration. The results from this experiment showed acceptable error rates are observed when the distance between them is less than 130cm. In the last experiment, the effects of varying video duration but with fixed distance are carried out. Acceptable error rates are observed between the actual and estimated video duration greater than 6 seconds.
format Thesis
author Ling, Siong Shi
author_facet Ling, Siong Shi
author_sort Ling, Siong Shi
title Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
title_short Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
title_full Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
title_fullStr Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
title_full_unstemmed Dynamic heart rate measurements from video sequences using canonical component analysis / Ling Siong Shi
title_sort dynamic heart rate measurements from video sequences using canonical component analysis / ling siong shi
publishDate 2019
url http://studentsrepo.um.edu.my/11398/1/Ling_Siong_Shi.jpg
http://studentsrepo.um.edu.my/11398/8/siong_shi.pdf
http://studentsrepo.um.edu.my/11398/
_version_ 1738506479058550784
score 13.211869